<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Loganetics</id>
	<title>FireAlarmPedia - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Loganetics"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php/Special:Contributions/Loganetics"/>
	<updated>2026-04-07T07:12:47Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=St._Patrick_Catholic_Church_(Northbridge,_MA,_USA)&amp;diff=8159</id>
		<title>St. Patrick Catholic Church (Northbridge, MA, USA)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=St._Patrick_Catholic_Church_(Northbridge,_MA,_USA)&amp;diff=8159"/>
		<updated>2024-05-13T00:27:28Z</updated>

		<summary type="html">&lt;p&gt;Loganetics: created page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;St. Patrick Catholic Church is a church located at 1 Cross St, Whitinsville, MA 01588. The church was built in 1898 and is currently still open. &lt;br /&gt;
&lt;br /&gt;
==System Specifications (unknown-present)==&lt;br /&gt;
===FACP===&lt;br /&gt;
The church is protected by an FCI FC-72 conventional fire alarm control panel. The specific one at the church has 4 zones.&lt;br /&gt;
&lt;br /&gt;
===Notification Appliances===&lt;br /&gt;
All indoor notification appliances are System Sensor SpectrAlert &amp;quot;Classic&amp;quot; horn strobes. There is an Edwards Adaptabel located near one of the doors, which most likely isn&#039;t connected to the fire alarm system but is worth mentioning.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPOs or some variant. They have glass rods installed and these pulls look like they are really old.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
All smoke detectors at this church are System Sensor 2151 Photoelectric smoke detectors. There are some old metal mechanical heat detectors as well, which may be branded by Edwards. There are some First Alert CO5120BN carbon monoxide alarms located near all of the classrooms, which replaced some older Kidde units. These Kidde alarms were replaced only a few years ago.&lt;/div&gt;</summary>