<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=ThePurpleMage</id>
	<title>FireAlarmPedia - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=ThePurpleMage"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php/Special:Contributions/ThePurpleMage"/>
	<updated>2026-04-07T07:18:46Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3528</id>
		<title>Pfeiffer Elementary School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3528"/>
		<updated>2022-04-08T14:47:15Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: Autocall 3FA32W29TA&lt;br /&gt;
System Type: Coded&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 1954&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1919&lt;br /&gt;
|}Pfeiffer Elementary School Is a public K-5 School located in Akron, OH. The school was built in 1919 and the fire alarm system was added in 1954, and is still in use today!&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Please note: this page was made from data by Glenn James (Old School Fire Alarms). All credit goes to him.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Autocall Model 3FA32W29TA coded fire alarm control system. It was  installed in 1954 when the school’s fire alarm system was automated, and is still in use after 65+ years! The panel is located in the boiler room. When in alarm the system does the marching cadence code 4-4-4-4.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Autocall Model 351-N “Vibratone” dual projector mechanical horns. There are also Reiter Co. 12 inch manual trip bells attached a pull rod mechanism.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Autocall Model NC Non-coded single action break glass stations. The is also a Reiter Co. manual pull rod attached to the Reiter Co. 12 inch manual trip bells and a switch that activates the alarms when the rod is pulled. The pull rod runs from the 3rd floor to the basement of the building  &lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3512</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3512"/>
		<updated>2022-04-07T22:12:44Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous &lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|In a box of stuff that I misplaced years ago&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Coder (Custom)&lt;br /&gt;
|16.5 A&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2019&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|IBM&lt;br /&gt;
4201-2&lt;br /&gt;
&lt;br /&gt;
(Soon to be obtained)&lt;br /&gt;
|&lt;br /&gt;
|Coded&lt;br /&gt;
|N/A&lt;br /&gt;
|2&lt;br /&gt;
NACs&lt;br /&gt;
|4-4&lt;br /&gt;
|&lt;br /&gt;
|Variable (based on how you set the resistors ) always AC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1940s&lt;br /&gt;
|Will be my oldest panel by far&lt;br /&gt;
|Glenn James&lt;br /&gt;
(Old School Fire Alarms)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&amp;quot;&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12LX&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-851&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2018?&lt;br /&gt;
|Came new old stock&lt;br /&gt;
|Phuntington&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-951&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2021&lt;br /&gt;
|Came brand new&lt;br /&gt;
|Phuntington&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3509</id>
		<title>Pfeiffer Elementary School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3509"/>
		<updated>2022-04-06T22:14:09Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: Autocall 3FA32W29TA&lt;br /&gt;
System Type: Coded&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 1954&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1919&lt;br /&gt;
|}Pfeiffer Elementary School Is a public K-5 School located in Akron, OH. The school was built in 1919 and the fire alarm system was added in 1954&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Autocall Model 3FA32W29TA coded fire alarm control panel. It was  installed in 1954 when the school’s fire alarm system was automated. The panel is located in the boiler room. When in alarm the system the marching cadence code 4-4-4-4&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Autocall Model 351-N “Vibratone” dual projector mechanical horns. There are also Reiter Co. 12 inch manual trip bells attached a pull rod mechanism&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Autocall Model NC Non-coded single action break glass stations. The is also a Reiter Co. manual pull rod attached to the Reiter Co. 12 inch manual trip bells and a switch that activates the alarms when the rod is pulled. The pull rod runs from the 3rd floor to the basement of the building  &lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3508</id>
		<title>Pfeiffer Elementary School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Pfeiffer_Elementary_School&amp;diff=3508"/>
		<updated>2022-04-06T22:13:25Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Very old system. Still in operation!!&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: Autocall 3FA32W29TA &lt;br /&gt;
System Type: Coded&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
NAC Voltage: 120VAC&lt;br /&gt;
Date of last known Upgrade: 1954&lt;br /&gt;
Year Opened: 1919&lt;br /&gt;
|}Pfeiffer Elementary School Is a public K-5 School located in Akron, OH. The school was built in 1919 and the fire alarm system was added in 1954&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Autocall Model 3FA32W29TA coded fire alarm control panel. It was  installed in 1954 when the school’s fire alarm system was automated. The panel is located in the boiler room. When in alarm the system the marching cadence code 4-4-4-4&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Autocall Model 351-N “Vibratone” dual projector mechanical horns. There are also Reiter Co. 12 inch manual trip bells attached a pull rod mechanism&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Autocall Model NC Non-coded single action break glass stations. The is also a Reiter Co. manual pull rod attached to the Reiter Co. 12 inch manual trip bells and a switch that activates the alarms when the rod is pulled. The pull rod runs from the 3rd floor to the basement of the building  &lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3500</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3500"/>
		<updated>2022-04-06T02:07:22Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: /* Panels (FACP) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous &lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|In a box of stuff that I misplaced years ago&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Coder (Custom)&lt;br /&gt;
|16.5 A&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2019&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|IBM&lt;br /&gt;
4201-2&lt;br /&gt;
&lt;br /&gt;
(Soon to be obtained)&lt;br /&gt;
|&lt;br /&gt;
|Coded&lt;br /&gt;
|N/A&lt;br /&gt;
|2&lt;br /&gt;
NACs&lt;br /&gt;
|4-4&lt;br /&gt;
|&lt;br /&gt;
|Variable (based on how you set the resistors ) always AC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1940s&lt;br /&gt;
|Will be my oldest panel by far&lt;br /&gt;
|Glenn James&lt;br /&gt;
(Old School Fire Alarms)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&amp;quot;&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12LX&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-851&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2018?&lt;br /&gt;
|Came new old stock&lt;br /&gt;
|Phuntington&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-951&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2022&lt;br /&gt;
|Came brand new&lt;br /&gt;
|Phuntington&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3499</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3499"/>
		<updated>2022-04-05T20:05:56Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: /* Panels (FACP) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous &lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|In a box of stuff that I misplaced years ago&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Coder (Custom)&lt;br /&gt;
|16.5 A&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2019&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|IBM&lt;br /&gt;
4201-2&lt;br /&gt;
&lt;br /&gt;
(Soon to be obtained)&lt;br /&gt;
|&lt;br /&gt;
|Coded&lt;br /&gt;
|N/A&lt;br /&gt;
|2&lt;br /&gt;
|4-4&lt;br /&gt;
|&lt;br /&gt;
|Variable (based on how you set the resistors ) always AC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1940s&lt;br /&gt;
|Will be my oldest panel by far&lt;br /&gt;
|Glenn James&lt;br /&gt;
(Old School Fire Alarms)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&amp;quot;&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12LX&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-851&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2018?&lt;br /&gt;
|Came new old stock&lt;br /&gt;
|Phuntington&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-951&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2022&lt;br /&gt;
|Came brand new&lt;br /&gt;
|Phuntington&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3498</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3498"/>
		<updated>2022-04-05T18:43:47Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: /* Panels (FACP) */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous &lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|In a box of stuff that I misplaced years ago&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Coder (Custom)&lt;br /&gt;
|16.5 A&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2019&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|IBM&lt;br /&gt;
4201-2&lt;br /&gt;
&lt;br /&gt;
(Soon to be obtained)&lt;br /&gt;
|&lt;br /&gt;
|Coded&lt;br /&gt;
|N/A&lt;br /&gt;
|2&lt;br /&gt;
|4-4&lt;br /&gt;
|&lt;br /&gt;
|120VAC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1940s&lt;br /&gt;
|Will be my oldest panel by far&lt;br /&gt;
|Glenn James&lt;br /&gt;
(Old School Fire Alarms)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&amp;quot;&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12LX&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-851&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2018?&lt;br /&gt;
|Came new old stock&lt;br /&gt;
|Phuntington&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-951&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2022&lt;br /&gt;
|Came brand new&lt;br /&gt;
|Phuntington&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3497</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3497"/>
		<updated>2022-04-05T18:24:22Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Fixed some spelling mistakes as well as adding some new stuff&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous &lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|In a box of stuff that I misplaced  years ago&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|Continuous&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Coder (Custom)&lt;br /&gt;
|16.5 A&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2019&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|IBM&lt;br /&gt;
4201-2&lt;br /&gt;
&lt;br /&gt;
(Soon to be obtained)&lt;br /&gt;
|&lt;br /&gt;
|Coded&lt;br /&gt;
|N/A&lt;br /&gt;
|2&lt;br /&gt;
|4-4&lt;br /&gt;
|&lt;br /&gt;
|120VAC&lt;br /&gt;
|120VAC&lt;br /&gt;
|Npne&lt;br /&gt;
|1940s&lt;br /&gt;
|Will be my oldest panel by far&lt;br /&gt;
|Glenn James&lt;br /&gt;
(Old School Fire Alarms)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&amp;quot;&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12LX&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-851&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2018?&lt;br /&gt;
|Came new old stock&lt;br /&gt;
|Phuntington&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
FSP-951&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke &lt;br /&gt;
Addressable&lt;br /&gt;
|2022&lt;br /&gt;
|Came brand new&lt;br /&gt;
|Phuntington&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3464</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3464"/>
		<updated>2022-03-22T02:35:30Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest panel&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|Lost, I can&#039;t find it&lt;br /&gt;
|Shane&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Custom&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2017&lt;br /&gt;
|My favourite panel.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch&lt;br /&gt;
F1GG &amp;quot;Chevron&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
NBG12L&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|Was formerly and NBG12LX&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing&lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
&lt;br /&gt;
2-Wire&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3463</id>
		<title>ThePurpleMage&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_Collection&amp;diff=3463"/>
		<updated>2022-03-22T02:05:35Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Made my collection page. Took two hours&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards &lt;br /&gt;
&lt;br /&gt;
2280&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|6 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1979&lt;br /&gt;
|My oldest  panel&lt;br /&gt;
|Carl&lt;br /&gt;
&lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Fire Lite &lt;br /&gt;
&lt;br /&gt;
Miniscan 112&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|4 Zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|1984&lt;br /&gt;
|Lost, I can&#039;t find it&lt;br /&gt;
|Shane&lt;br /&gt;
&lt;br /&gt;
(Sprouse) &lt;br /&gt;
|-&lt;br /&gt;
|Notifier/Emhart&lt;br /&gt;
&lt;br /&gt;
Unknown Model&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|None of the LEDs work&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone&lt;br /&gt;
70605&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|1 Zone&lt;br /&gt;
|1 NAC&lt;br /&gt;
|None&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|My Rarest panel. I&#039;m the only collector to own one&lt;br /&gt;
|Carl (Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier &lt;br /&gt;
AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|99 Points (Modules)&lt;br /&gt;
99 Points&lt;br /&gt;
&lt;br /&gt;
(Detectors)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Continuous, Temporal, 120BPM, California&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Wheelock, Gentex&lt;br /&gt;
|2002&lt;br /&gt;
|&lt;br /&gt;
|Carl &lt;br /&gt;
(Legacy)&lt;br /&gt;
|-&lt;br /&gt;
|EST &lt;br /&gt;
IO-1000&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|1000&lt;br /&gt;
|8 NACs&lt;br /&gt;
|Continuous, Temporal, Custom&lt;br /&gt;
|&lt;br /&gt;
|24VFWR&lt;br /&gt;
|120VAC&lt;br /&gt;
|Genesis&lt;br /&gt;
|2017&lt;br /&gt;
|My favourite panel. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In a retrofit cabinet&lt;br /&gt;
|Carl&lt;br /&gt;
(Legacy)&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Sound Output&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
&lt;br /&gt;
439D-6AWC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|98db&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Simplex&lt;br /&gt;
&lt;br /&gt;
2901 2723&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|Unkown&lt;br /&gt;
|2012&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Some old horn&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mechanical horn&lt;br /&gt;
|&lt;br /&gt;
|12VAC&lt;br /&gt;
|&lt;br /&gt;
|133db&lt;br /&gt;
|Unknown&lt;br /&gt;
|LOUD!!!!&lt;br /&gt;
&lt;br /&gt;
looks looks like it could have a projector&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
G1-HDVM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|103db&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|EST &lt;br /&gt;
G1-VM&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi CD&lt;br /&gt;
|&lt;br /&gt;
|2017&lt;br /&gt;
|&lt;br /&gt;
|Carl (Lagacy)&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Horn/Storbe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75 CD&lt;br /&gt;
|Varying&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing &lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex &lt;br /&gt;
4251-20&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|AdenK2333&lt;br /&gt;
|-&lt;br /&gt;
|Couch &lt;br /&gt;
F1GG &amp;quot;Chevron&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|Broke from being slammed&lt;br /&gt;
|Shane (Sprouse)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier &lt;br /&gt;
NBG12L&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|Was formerly and NBG12LX&lt;br /&gt;
|Unknown&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Notifier&lt;br /&gt;
MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
270-SPOW&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single Action&lt;br /&gt;
Single Stage&lt;br /&gt;
&lt;br /&gt;
Conventional&lt;br /&gt;
|&lt;br /&gt;
|Switch is no longer functional. Screw is so stripped its unusable&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== Automatic Detectors ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Image&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing &lt;br /&gt;
Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Edwards&lt;br /&gt;
C2M-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Conventional&lt;br /&gt;
|Unknown&lt;br /&gt;
|&lt;br /&gt;
|YYCFireAlarmNimrod&lt;br /&gt;
|-&lt;br /&gt;
|EST&lt;br /&gt;
SIGA-PD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Photo Smoke&lt;br /&gt;
Addressable&lt;br /&gt;
|2017&lt;br /&gt;
|Came brand new&lt;br /&gt;
|EST Tech&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant&lt;br /&gt;
V-HRD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Rate of Rise Heat&lt;br /&gt;
Addressable&lt;br /&gt;
|Unkown&lt;br /&gt;
|&lt;br /&gt;
|Unknown&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=TwentyThree33%27s_Collection&amp;diff=3460</id>
		<title>TwentyThree33&#039;s Collection</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=TwentyThree33%27s_Collection&amp;diff=3460"/>
		<updated>2022-03-21T22:28:26Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Added the FA-1025T because Adam didn&amp;#039;t&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;I have the largest collection in Alberta, and also the largest of the Wiki staff. &lt;br /&gt;
=== Panels (FACP) ===&lt;br /&gt;
{| class=&amp;quot;wikitable sortable mw-collapsible&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model&lt;br /&gt;
!Image&lt;br /&gt;
!Type&lt;br /&gt;
!Zone/Point Capacity&lt;br /&gt;
!NACs&lt;br /&gt;
!Coding Options&lt;br /&gt;
!Power Supply&lt;br /&gt;
!NAC Voltage&lt;br /&gt;
!System Line Voltage&lt;br /&gt;
!Synchronization Support&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4010&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|250 points&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Code 3, 120BPM March Time, 20BPM March Time, Continuous&lt;br /&gt;
|4A (expandable to 8A)&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|SmartSync (Simplex), Wheelock&lt;br /&gt;
|2008&lt;br /&gt;
|&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Mircom&lt;br /&gt;
FA-1025T&lt;br /&gt;
|&lt;br /&gt;
|Conventional&lt;br /&gt;
|5 zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Code 3, Continuous,&lt;br /&gt;
75 BPM&lt;br /&gt;
|1.5 Amps&lt;br /&gt;
|28VFWR&lt;br /&gt;
|120VAC/&lt;br /&gt;
240VAC&lt;br /&gt;
|None&lt;br /&gt;
|2015&lt;br /&gt;
|Missing the dress panel and has replacement lock&lt;br /&gt;
|ThePurpleMage&lt;br /&gt;
|-&lt;br /&gt;
|Honeywell Vista 32FB&lt;br /&gt;
|&lt;br /&gt;
|Conventional (Combined Fire and Burglary)&lt;br /&gt;
|12 zones&lt;br /&gt;
|2 NACs&lt;br /&gt;
|None&lt;br /&gt;
|Unknown&lt;br /&gt;
|12VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|N/A&lt;br /&gt;
|2009&lt;br /&gt;
|&lt;br /&gt;
|Air Canada Commissary (replaced by a DSC Powerseries)&lt;br /&gt;
|-&lt;br /&gt;
|Notifier AFP-200C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|198 points (99 detectors, 99 modules/pulls)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Code 3, Continuous, March Time, California Code, Two-Stage&lt;br /&gt;
|6A&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|N/A&lt;br /&gt;
|2003&lt;br /&gt;
|Currently the main panel on my system. Also my personal favourite!&lt;br /&gt;
|[[40 Sunpark Plaza SE]]&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NFS-320C&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|318 points (159 detectors, 159 modules)&lt;br /&gt;
|4 NACs&lt;br /&gt;
|Code 3, Continuous, March Time, California Code, Two-Stage&lt;br /&gt;
|6A&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Gentex, Wheelock&lt;br /&gt;
|2010&lt;br /&gt;
|Has an internal ground fault, and issues with the SLC. Will be getting a replacement soon.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NFW-50&lt;br /&gt;
|&lt;br /&gt;
|Addressable&lt;br /&gt;
|50 points&lt;br /&gt;
|2 NACs&lt;br /&gt;
|Code 3, Continuous, March Time, California Code, Two-Stage&lt;br /&gt;
|2.5A&lt;br /&gt;
|24VDC&lt;br /&gt;
|120VAC&lt;br /&gt;
|System Sensor, Gentex, Wheelock&lt;br /&gt;
|2012&lt;br /&gt;
|Puts out the cleanest DC out of any of my panels.&lt;br /&gt;
|Sunpark Plaza Building A&lt;br /&gt;
|}&lt;br /&gt;
=== Notification Appliances ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images &lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Product Line&lt;br /&gt;
!Voltage&lt;br /&gt;
!Strobe Intensity&lt;br /&gt;
!Loudness&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 2901-9720&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Motor Bell (6&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|1988 (1), 1993 (2)&lt;br /&gt;
|One has a metal striker housing, and two have plastic housings.&lt;br /&gt;
|[[R.T. Alderman School]] (1), CJ9899 (2)&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 2901-9722&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Motor Bell (10&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|90dB&lt;br /&gt;
|1988&lt;br /&gt;
|Very rare bell. Myself and CJ9899 are the only two enthusiasts to have one.&lt;br /&gt;
|[[R.T. Alderman School]]&lt;br /&gt;
|-&lt;br /&gt;
|Amseco PBA-6-120&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell (6&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|120VAC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|2005&lt;br /&gt;
|&lt;br /&gt;
|[[7044 Ogden Road SE]]&lt;br /&gt;
|-&lt;br /&gt;
|Potter PBA-6-120&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell (6&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|120VAC&lt;br /&gt;
|N/A&lt;br /&gt;
|Unknown&lt;br /&gt;
|Unknown&lt;br /&gt;
|Does not work. Was used as a sprinkler bell.&lt;br /&gt;
|Some warehouse in Foothills Industrial.&lt;br /&gt;
|-&lt;br /&gt;
|Mircom BL-6A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Motor Bell (6&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|2006&lt;br /&gt;
|Was from an eBay seller, but I got it for free. Now owned by Temporal Engineering.&lt;br /&gt;
|Cube_Inc (eBay seller)&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4903-9219&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Electromechanical Horn/strobe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15cd&lt;br /&gt;
|90dB&lt;br /&gt;
|1997&lt;br /&gt;
|Got it for $15. Healthiest sounding 9219 I&#039;ve ever heard.&lt;br /&gt;
|eBay&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4906-9102&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|TrueAlert&lt;br /&gt;
|24VDC (requires SmartSync)&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|39dB&lt;br /&gt;
|2016?&lt;br /&gt;
|Clips are essentially destroyed to make removal easier.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Wheelock MT-241575W-FR&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Multi-tone Horn/strobe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|15/75cd&lt;br /&gt;
|90/95dB&lt;br /&gt;
|2000s&lt;br /&gt;
|One of my favorite horn/strobes.&lt;br /&gt;
|Viking Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Siemens MTH-75-R-WP-B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Weatherproof Multi-tone Horn/strobe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|30cd&lt;br /&gt;
|90/95dB&lt;br /&gt;
|2000s&lt;br /&gt;
|Screws on the back are rusted, but device is fully functional.&lt;br /&gt;
|Viking Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor P2RA&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Electronic Horn/strobe&lt;br /&gt;
|SpectrAlert Advance&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|90/95/100dB&lt;br /&gt;
|2006, 2007&lt;br /&gt;
|VERY LOUD. But overall very good alarms. I just wish they were 4-wire.&lt;br /&gt;
|Viking Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor SRA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|SpectrAlert Advance&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|N/A&lt;br /&gt;
|2010s&lt;br /&gt;
|Very, very good device. My favourite remote strobe out there.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Siemens ZR-MC-W-B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Remote Strobe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|N/A&lt;br /&gt;
|2010s&lt;br /&gt;
|Quite a rare device. Terminals are kind of dumb though.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 757-5A-T&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Electronic Horn/strobe&lt;br /&gt;
|Integrity&lt;br /&gt;
|24VDC&lt;br /&gt;
|15cd&lt;br /&gt;
|75dB&lt;br /&gt;
|1997&lt;br /&gt;
|Horn is damaged, so it is extremely quiet. My dog likes it though!&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|GE 682-1C&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mini-horn&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|75dB&lt;br /&gt;
|2009?&lt;br /&gt;
|The best looking mini horn, in my opinion.&lt;br /&gt;
|Thomas Barnable&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 6100D&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell (6&amp;quot;)&lt;br /&gt;
|Durabel&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|1981&lt;br /&gt;
|Very quiet bell. Also acquired for free. Has minor striker issues, sometimes doesn&#039;t sound if set on the floor.&lt;br /&gt;
|Cube_Inc (eBay seller)&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 892-2B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Electronic Horn/strobe&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|1.5cd&lt;br /&gt;
|N/A&lt;br /&gt;
|1992&lt;br /&gt;
|Horn is non-functional, and was thrown away by my parents. Nice going, jerkbags.&lt;br /&gt;
|eBay&lt;br /&gt;
|-&lt;br /&gt;
|ADT 3210-013M&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Vibrating Bell (6&amp;quot;)&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|1982&lt;br /&gt;
|Very, very, very rare bell. I&#039;m the only enthusiast to have one. Sounds very similar to the Simplex 2901-9720.&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor P4RLA&lt;br /&gt;
|&lt;br /&gt;
|6&lt;br /&gt;
|4 wire electronic horn/strobe&lt;br /&gt;
|L-Series&lt;br /&gt;
|12VDC/24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|85? dB&lt;br /&gt;
|2021&lt;br /&gt;
|Very nice device. Acquired NIB.&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Kidde G1R-VM&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Remote strobe&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|N/A&lt;br /&gt;
|2017?&lt;br /&gt;
|From the &amp;quot;Genesis&amp;quot; line of products.&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor MHWZA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Silenceable Mini-Horn&lt;br /&gt;
|SpectrAlert Advance&lt;br /&gt;
|24VDC&lt;br /&gt;
|N/A&lt;br /&gt;
|85dB&lt;br /&gt;
|&lt;br /&gt;
|From the &amp;quot;SpectrAlert Advance&amp;quot; line of products. Acquired NIB.&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Mircom MH-S25WA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Silenceable Mini-Horn&lt;br /&gt;
|&lt;br /&gt;
|24VDC&lt;br /&gt;
|&lt;br /&gt;
|85dB&lt;br /&gt;
|&lt;br /&gt;
|Very, very, very common device in apartments. Acquired new, no box.&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Edwards G1AVRF&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Electronic Horn/Strobe (horn not functional)&lt;br /&gt;
|Genesis&lt;br /&gt;
|24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|90dB (N/A)&lt;br /&gt;
|2019&lt;br /&gt;
|These have very sucky strobes.&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor P2WA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Electronic Horn/Strobe (white)&lt;br /&gt;
|SpectrAlert Advance&lt;br /&gt;
|12VDC/24VDC&lt;br /&gt;
|Multi-candela&lt;br /&gt;
|90dB, 95dB, 102dB&lt;br /&gt;
|2010s&lt;br /&gt;
|Rare device! Very nice looking.&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
=== Pull Stations ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
! Quantity&lt;br /&gt;
!Type&lt;br /&gt;
! Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
!Origin&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 2099-9901&lt;br /&gt;
|&lt;br /&gt;
| 2&lt;br /&gt;
|Single-stage, SPST, single-action Conventional Pull Station&lt;br /&gt;
|1988&lt;br /&gt;
| The button on one is from a Mirtone 73303.&lt;br /&gt;
|[[R.T. Alderman School]]&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4099-9004&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|IDNet Addressable single-stage, single-action pull station&lt;br /&gt;
|2018&lt;br /&gt;
|Missing its lock.&lt;br /&gt;
|Canadian Alarms&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4099-9004CB&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|IDNet Addressable single-stage, single-action bilingual pull station&lt;br /&gt;
|2017&lt;br /&gt;
|Fairly rare.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4251-30&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST, break-glass dual-action conventional pull station&lt;br /&gt;
|1979&lt;br /&gt;
|Owned by [[User:Simplex NimrodES|Simplex NimrodES]], but was loaned to me with permission.&lt;br /&gt;
|Kijiji&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 270-SPO&lt;br /&gt;
|&lt;br /&gt;
|4&lt;br /&gt;
|Single-stage, SPST, single-action conventional pull station&lt;br /&gt;
|1960s, 1980s, 1990s, 2000&lt;br /&gt;
|1960s one is surprisingly hard to pull! 1980s one does not work.&lt;br /&gt;
|El Chupacabra, Canadian Alarms, other friend&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 270-SPOF&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST, single-action conventional pull station&lt;br /&gt;
|1980s&lt;br /&gt;
|French lettering&lt;br /&gt;
|El Chupacabra&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 270A-SPO&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST, single-action conventional pull station&lt;br /&gt;
|1994&lt;br /&gt;
|American model, in remarkably good condition.&lt;br /&gt;
|El Chupacabra&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 270-SPOWB&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Bilingual, Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|2014&lt;br /&gt;
|Pretty interesting device.&lt;br /&gt;
|[[User:Twentytwo22|Twentytwo22]]&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 270-GAO-DOC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual-stage, DPST, single-action conventional pull station&lt;br /&gt;
|1997, 2003&lt;br /&gt;
|Very rare but cool pull stations. Both have the security screw.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|EST SIGA-270P&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Addressable dual-stage, single-action pull station&lt;br /&gt;
|2016&lt;br /&gt;
|Soon to be owned by [[User:Twentytwo22|Twentytwo22]]&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Siemens MS-53C&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Dual-stage, DPST single-action conventional pull station&lt;br /&gt;
|2014&lt;br /&gt;
|Very good pull stations overall, but why are terminals 1 and 4 for the button, and 2 and 3 for the keyswitch?&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Pyrotronics MS-51B&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|1980s&lt;br /&gt;
|One of my personal favourites! Very rare too.&lt;br /&gt;
|El Chupacabra&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone 73303&lt;br /&gt;
|&lt;br /&gt;
|4&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|1986, 1988, 1992&lt;br /&gt;
|The reset difficulty is significantly over-exaggerated. It&#039;s really not that hard.&lt;br /&gt;
|El Chupacabra, Canadian Alarms&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone 73353&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|1997&lt;br /&gt;
|I&#039;m the only known enthusiast to have this alarm.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Notifier MPS-950B&lt;br /&gt;
|&lt;br /&gt;
|1 (formerly 2)&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|2001&lt;br /&gt;
|Metal bar that holds the handle in place is loose on both. Frequent adjustment is required. One now owned by ThePurpleMage.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Fire-Lite BG-12L&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST dual-action conventional pull station&lt;br /&gt;
|2014&lt;br /&gt;
|&lt;br /&gt;
|[[User:Twentytwo22|Twentytwo22]]&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 275-C111&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|1992&lt;br /&gt;
|Very, very nice pull station. I&#039;d highly recommend purchasing one.&lt;br /&gt;
|Canadian Alarms&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 274-111&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|1970s&lt;br /&gt;
|Not a very well-made device. The 275-C111 is much better.&lt;br /&gt;
|[[7044 Ogden Road SE]]&lt;br /&gt;
|-&lt;br /&gt;
|Mircom MS-401AD&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Addressable single-stage, single-action pull station&lt;br /&gt;
|2008&lt;br /&gt;
|&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Mircom MS-401&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|2014&lt;br /&gt;
|Basic but nice pull station. The edges are really sharp on this one. I actually cut myself pulling it once. Now owned my ThePurpleMage.&lt;br /&gt;
|Canadian Alarms&lt;br /&gt;
|-&lt;br /&gt;
|Notifier MPS-950KB20C&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual-stage, DPST single-action conventional pull station&lt;br /&gt;
|2013?&lt;br /&gt;
|Weird pull station overall, but in very good condition.&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|Honeywell FM-950K&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Dual-stage, SPST single-action conventional pull station&lt;br /&gt;
|1980s&lt;br /&gt;
|&lt;br /&gt;
|CJ9899&lt;br /&gt;
|-&lt;br /&gt;
|FCI MS-2E&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST dual-action conventional pull station&lt;br /&gt;
|2000s&lt;br /&gt;
|Labeled &amp;quot;EPO and Disconnect&amp;quot;, has an issue with the pulling mechanism.&lt;br /&gt;
|eBay&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 2099-9754&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action conventional pull station&lt;br /&gt;
|2010&lt;br /&gt;
|One of my favorites.&lt;br /&gt;
|eBay&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NOT-BG12LX&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Addressable single-stage dual-action pull station&lt;br /&gt;
|2011&lt;br /&gt;
|Works with the FireWarden (NFW) panels only.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NBG-12LX&lt;br /&gt;
|&lt;br /&gt;
|3&lt;br /&gt;
|Addressable single-stage dual-action pull station&lt;br /&gt;
|2016, 2019&lt;br /&gt;
|Works with the AFP and Onyx-series panels. Runs on both FlashScan and CLIP. Two acquired new. One was acquired due to it &amp;quot;not working&amp;quot;, despite working fine. One acquired used, has issues with connection between module and switch.&lt;br /&gt;
|[[Phuntington]], PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Notifier N-MPS-SA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Addressable single-stage single-action pull station&lt;br /&gt;
|2020&lt;br /&gt;
|Was acquired new as a birthday present from Steve Huska, regional manager at Viking Fire Protection.&lt;br /&gt;
|Viking Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Notifier N-MPS-2A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Addressable dual-stage dual-action pull station&lt;br /&gt;
|2021&lt;br /&gt;
|Very unique device.&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Notifier N-MPS-SC&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST single-action pull station&lt;br /&gt;
|2018&lt;br /&gt;
|&lt;br /&gt;
|PDS Fire Protection&lt;br /&gt;
|-&lt;br /&gt;
|Notifier LNG-1R&lt;br /&gt;
|&lt;br /&gt;
|4&lt;br /&gt;
|Single-stage, SPST dual-action conventional pull station&lt;br /&gt;
|December 1998&lt;br /&gt;
|Very rare pull stations! Very good devices, but quite fragile.&lt;br /&gt;
|Nick Olvera&lt;br /&gt;
|-&lt;br /&gt;
|Mirtone 73201&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Single-stage, SPST dual-action conventional pull station&lt;br /&gt;
|1991&lt;br /&gt;
|My favourite pull station of all time!&lt;br /&gt;
|Canadian Alarms&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 278B-1120&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Single-stage, SPST dual-action conventional pull station&lt;br /&gt;
|2007&lt;br /&gt;
|One has a switch from a 270-SPO, and is missing the terminals.&lt;br /&gt;
|ThePurpleMage&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NFM-950KB&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Dual-stage, SPST single-action conventional pull station&lt;br /&gt;
|1990s&lt;br /&gt;
|Rare! Actually manufactured by Electro-Vox. Tab is quite loose, but still works. Uses barrel-style GA key.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|-&lt;br /&gt;
|Vigilant GSA-M270&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Addressable single-action pull station&lt;br /&gt;
|2013?&lt;br /&gt;
|Mediocre pull station. Not very good.&lt;br /&gt;
|[[Phuntington]]&lt;br /&gt;
|}&lt;br /&gt;
=== Automatic Detection Devices ===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
! Quantity&lt;br /&gt;
!Type&lt;br /&gt;
! Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
|-&lt;br /&gt;
|Edwards C2M-PD&lt;br /&gt;
|&lt;br /&gt;
| 5&lt;br /&gt;
|Photoelectric Self-diagnosing Smoke Detector&lt;br /&gt;
|2000s&lt;br /&gt;
| Pulled out a crapload of these a while ago.&lt;br /&gt;
|-&lt;br /&gt;
|System Sensor C2W-BA&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Two-wire i3 photoelectric smoke detector&lt;br /&gt;
|2010s&lt;br /&gt;
|One acquired used, condition of other is unknown.&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4098-9714&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|IDNet addressable photoelectric smoke detector&lt;br /&gt;
|2019&lt;br /&gt;
|Acquired new.&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4098-9734&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|IDNet addressable fixed/rate-of-rise heat detector&lt;br /&gt;
|2018&lt;br /&gt;
|Acquired new.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FSP-851A&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|CLIP/FlashScan addressable photoelectric smoke detector&lt;br /&gt;
|2012&lt;br /&gt;
|One currently in use on my main board. Acquired used/new,&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FSL-751A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Very Intelligent Early Warning (VIEW) CLIP/FlashScan laser smoke detector&lt;br /&gt;
|2007&lt;br /&gt;
|Very, very cool device. This came out of an Enmax building.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FDX-551RA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP addressable fixed/rate-of-rise heat detector&lt;br /&gt;
|1990s&lt;br /&gt;
|Was uninstalled following a fire, has some of the plastic housing melted off. Still works though!&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FST-851A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP/FlashScan addressable fixed/rate-of-rise heat detector&lt;br /&gt;
|2010s&lt;br /&gt;
|Acquired new.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FSP-951A&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|FlashScan addressable photoelectric smoke detector&lt;br /&gt;
|2021&lt;br /&gt;
|Acquired brand new.&lt;br /&gt;
|-&lt;br /&gt;
|Edwards 6249C&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Ionization smoke detector (4-wire)&lt;br /&gt;
|1990s&lt;br /&gt;
|One came NIB.&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 2098-9110&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Ionization smoke detector (2-wire)&lt;br /&gt;
|1988&lt;br /&gt;
|Came from [[R.T. Alderman School]]. Rebrand of the System Sensor 1400.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FST-751RA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP/FlashScan fixed/rate-of-rise heat detector&lt;br /&gt;
|2000s?&lt;br /&gt;
|Not tested, but I find these look better than the 851 or 951.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier CPX-551A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP addressable Ionization Smoke Detector&lt;br /&gt;
|1998?&lt;br /&gt;
|Tested, and activates almost as quick as a modern photoelectric.&lt;br /&gt;
|}&lt;br /&gt;
====Accessories====&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Model Number&lt;br /&gt;
!Images&lt;br /&gt;
!Quantity&lt;br /&gt;
!Type&lt;br /&gt;
!Manufacturing Date&lt;br /&gt;
!Notes&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FMM-1A&lt;br /&gt;
|&lt;br /&gt;
|5&lt;br /&gt;
|Full-size CLIP/FlashScan addressable module (Canadian)&lt;br /&gt;
|2006 (1), 2009 (1), 2014 (1), 2020 (2)&lt;br /&gt;
|These are very useful if you have a Notifier system. One is NIB, one is BNIB. 2006 model is currently set as point #2 on my AFP-200.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FMM-101A&lt;br /&gt;
|&lt;br /&gt;
|5&lt;br /&gt;
|Mini CLIP/FlashScan addressable module (Canadian)&lt;br /&gt;
|2003 (2), 2010s (3)&lt;br /&gt;
|Only 4 are functional. One is likely water damaged. One is NIB. One set as point #3 on my AFP-200.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier MMX-101A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|Mini CLIP addressable module (Canadian)&lt;br /&gt;
|1990s&lt;br /&gt;
|Currently on my AFP-200, set as point #1.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier MMX-101&lt;br /&gt;
|&lt;br /&gt;
|6&lt;br /&gt;
|Mini CLIP addressable module (USA)&lt;br /&gt;
|1998&lt;br /&gt;
|Came from Mr. Nick. Were attached to LNG-1R pulls initially.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FRM-1A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP/FlashScan relay module (Canadian)&lt;br /&gt;
|2010s&lt;br /&gt;
|Not sure what to use it for.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier FCM-1A&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|CLIP/FlashScan control module&lt;br /&gt;
|2010s&lt;br /&gt;
|Basically a NAC without coding. Likely going to use it for strobes.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier XP10-MA&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|10-zone CLIP/FlashScan conventional zone module&lt;br /&gt;
|2010s&lt;br /&gt;
|Will be used to replace all addressable modules on my board.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier NMM-100A&lt;br /&gt;
|&lt;br /&gt;
|2&lt;br /&gt;
|Full-size FireWarden addressable module (Canadian)&lt;br /&gt;
|2011&lt;br /&gt;
|One will be going to Caleb Groves.&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4090-9001&lt;br /&gt;
|&lt;br /&gt;
|4&lt;br /&gt;
|IDNet individual addressable module (IAM)&lt;br /&gt;
|2000s-2019&lt;br /&gt;
|All came from CJ9899, and all work. Obscure resistor values though, and not all are the same.&lt;br /&gt;
|-&lt;br /&gt;
|Simplex 4090-9002&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|IDNet relay module&lt;br /&gt;
|2010s?&lt;br /&gt;
|I&#039;ve never used it. CJ9899 might&#039;ve though.&lt;br /&gt;
|-&lt;br /&gt;
|Edwards EOL-P1&lt;br /&gt;
|&lt;br /&gt;
|7?&lt;br /&gt;
|End-of-line resistor plate, white, plastic&lt;br /&gt;
|2000s-2019&lt;br /&gt;
|These need better terminals. I&#039;ve almost broke several resistors using these. I do like how these come with any kind of resistor you can imagine, though.&lt;br /&gt;
|-&lt;br /&gt;
|Mircom MP-300&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|End-of-line resistor plate, white, plastic&lt;br /&gt;
|2000s (judging by older logo)&lt;br /&gt;
|Pretty much the same as the Edwards plate above, except for a few differences. The stickers on the back are different, the resistor symbol on the front is vertical instead of horizontal, there&#039;s a Mircom logo on the front, and the screws are Phillips, not Robertson.&lt;br /&gt;
|-&lt;br /&gt;
|Notifier EOL-CR&lt;br /&gt;
|&lt;br /&gt;
|1&lt;br /&gt;
|End-of-line resistor plate, red, metal&lt;br /&gt;
|2000s?&lt;br /&gt;
|Much, much better than the Edwards and Mircom plates. These are significantly better quality, albeit mine is pretty beat up.&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3415</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3415"/>
		<updated>2022-03-09T03:40:25Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO1000 &amp;lt;br /&amp;gt;System Type: Hybrid &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;Date of last update: December 2021 &amp;lt;br /&amp;gt;Year Installed: 2017&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;ThePurpleMage’s&#039;&#039;&#039; house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt; Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST iO1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021.&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex [[Tel:2901-9723|2901-9723]] (6 inch) motor bells.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PD addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3414</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3414"/>
		<updated>2022-03-09T03:39:53Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Fixed a typo&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO1000 &amp;lt;br /&amp;gt;System Type: Hybrid &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;Date of last update: December 2021 &amp;lt;br /&amp;gt;Year Installed: 2017&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;ThePurpleMage’s&#039;&#039;&#039; house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt; Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST iO1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021.&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex [[Tel:2901-9723|2901-9723]] (6 inch) motor bells.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PD&lt;br /&gt;
&lt;br /&gt;
D addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Westbrook_Station&amp;diff=3404</id>
		<title>Westbrook Station</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Westbrook_Station&amp;diff=3404"/>
		<updated>2022-03-06T03:51:01Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100ES InfoAlarm &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2021&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Westbrook Station&#039;&#039;&#039; is an CTrain LRT station in SW Calgary, it was opened in 2012 as part of the West LRT on the Calgary Transit Blue Line. The fire alarm system is original.&lt;br /&gt;
== System Specifications ==&lt;br /&gt;
==== FACP ====&lt;br /&gt;
The fire alarm panel is a Simplex 4100ES InfoAlarm and it is original to the station. The panel is one bay, and is located at the West entrance. The system does code 3 when in alarm, and all strobes are synchronized.&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
The notification appliances are mainly Simplex &amp;quot;TrueAlert&amp;quot; 4906-9131 (red, wall) weatherproof horn/strobes. One of them is mounted low at an entrance. In the library, there are Simplex &amp;quot;TrueAlert&amp;quot; 4906-9127 (red, wall) horn/strobes.&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
The pull stations consist of Simplex 4099-9001 addressable single action T-bar pull stations.&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
None noticed.&lt;br /&gt;
[[Category:Facilities]]&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3379</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3379"/>
		<updated>2022-02-28T04:24:22Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO1000 &amp;lt;br /&amp;gt;System Type: Hybrid &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;Date of last update: December 2021 &amp;lt;br /&amp;gt;Year Installed: 2017&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;ThePurpleMage’s&#039;&#039;&#039; house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt; Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST iO1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021.&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex 2901-9723 (6 inch) motor bells.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PCD addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3371</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3371"/>
		<updated>2022-02-27T18:31:29Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO1000 &amp;lt;br /&amp;gt;System Type: Hybrid &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;Date of last update: December 2021 &amp;lt;br /&amp;gt;Year Installed: 2017&lt;br /&gt;
|}&lt;br /&gt;
ThePurpleMage’s house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt; Note: This system is owned and controlled by a user of this wiki, and can activate it at any time because it is in a controlled environment. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST iO1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021.&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex 2901-9723 (6 inch) motor bells.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PCD addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3370</id>
		<title>Webber Academy</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3370"/>
		<updated>2022-02-27T17:57:58Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: EST 3&lt;br /&gt;
System Type: Addressable/Hybrid&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage: 24VDC&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 2016&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
|}&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
Webber Academy is a private K-12 school located just west of Calgary, AB. The school was built in 1997 but in 2016 the school was expanded and a performing arts centre was built.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST 3 addressable fire alarm control panel. It was likely installed when the school was expanded. The panel is located in the front entrance.  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Edwards 439D-10AWC (10 inch) vibrating bells (A mix of the newer variety with the white and red labels and the older variety with the gold labels) mounted on Edwards “Integrity” 403-5A-R strobe plates.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix Edwards 270-SPO conventional single action pull stations from different eras, and EST SIGA 270 addressable single action pull stations. The conventional pull stations would be wired into SIGA CT-1 monitor modules.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA PS Photoelectric smoke detectors located throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3369</id>
		<title>Webber Academy</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3369"/>
		<updated>2022-02-27T17:55:28Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: EST 3&lt;br /&gt;
System Type: Addressable/Hybrid&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage: 24VFWR&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 2016&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
|}&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
Webber Academy is a private K-12 school located just west of Calgary, AB. The school was built in 1997 but in 2016 the school was expanded and a performing arts centre was built.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST 3 addressable fire alarm control panel. It was likely installed when the school was expanded. The panel is located in the front entrance.  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Edwards 439D-10AWC (10 inch) vibrating bells (A mix of the newer variety with the white and red labels and the older variety with the gold labels) mounted on Edwards “Integrity” 403-5A-R strobe plates.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix Edwards 270-SPO conventional single action pull stations from different eras, and EST SIGA 270 addressable single action pull stations. The conventional pull stations would be wired into SIGA CT-1 monitor modules.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA PS Photoelectric smoke detectors located throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3368</id>
		<title>Webber Academy</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3368"/>
		<updated>2022-02-27T17:53:21Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: EST 3&lt;br /&gt;
System Type: Addressable/Hybrid&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
NAC Voltage: 24VFWR&lt;br /&gt;
Date of last known Upgrade: 2016&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
Webber Academy is a private K-12 school located just west of Calgary, AB. The school was built in 1997 but in 2016 the school was expanded and a performing arts centre was built.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST 3 addressable fire alarm control panel. It was likely installed when the school was expanded. The panel is located in the front entrance.  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Edwards 439D-10AWC (10 inch) vibrating bells (A mix of the newer variety with the white and red labels and the older variety with the gold labels) mounted on Edwards “Integrity” 403-5A-R strobe plates.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix Edwards 270-SPO conventional single action pull stations from different eras, and EST SIGA 270 addressable single action pull stations. The conventional pull stations would be wired into SIGA CT-1 monitor modules.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA PS Photoelectric smoke detectors located throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3367</id>
		<title>Webber Academy</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Webber_Academy&amp;diff=3367"/>
		<updated>2022-02-27T17:50:53Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Decently average EST bell strobe system&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: EST 3&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
System Type: Addressable/Hybrid&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage: 24VFWR&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 2016&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1997&lt;br /&gt;
|}Webber Academy is a private K-12 school located just west of Calgary, AB. The school was built in 1997 but in 2016 the school was expanded and a performing arts centre was built.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST 3 addressable fire alarm control panel. It was likely installed when the school was expanded. The panel is located in the front entrance.  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Edwards 439D-10AWC (10 inch) vibrating bells (A mix of the newer variety with the white and red labels and the older variety with the gold labels) mounted on Edwards “Integrity” 403-5A-R strobe plates.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix Edwards 270-SPO conventional single action pull stations from different eras, and EST SIGA 270 addressable single action pull stations. The conventional pull stations would be wired into SIGA CT-1 monitor modules.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA PS Photoelectric smoke detectors located throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Calaway_Cafe&amp;diff=3366</id>
		<title>Calaway Cafe</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Calaway_Cafe&amp;diff=3366"/>
		<updated>2022-02-27T17:21:42Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &amp;quot;the CMP-2402 is the only conventional panel Fire-Lite offers in Canada&amp;quot; This is false as I have seen a Sensiscan 1000 and an MS5UD&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Fire-Lite CMP-2402 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;Date of last known Upgrade: 2017 &amp;lt;br /&amp;gt;Year Opened: 1982&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Calaway Park&#039;&#039;&#039; is a large amusement park located just west of Calgary, in Springbank, Alberta. This page will cover the Calaway Cafe, which is the main cafeteria in the park, and possibly the only building in the park with a fire alarm system. The building was built in 1982, when the park opened. The system was replaced in 2017, however.&lt;br /&gt;
==System Specifications (current system)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Fire-Lite CMP-2402 conventional fire alarm system. However this is unconfirmed. This panel has no coding options, so the system does continuous in alarm.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). These were not replaced when the system was upgraded, and are original.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Fire-Lite FI-MPS-SC conventional single-action “T-bar” pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are possibly System Sensor i3 C2W-BA conventional smoke detectors in the building.&lt;br /&gt;
==System Specifications (original system)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building was protected by an Edwards 1527 conventional fire alarm system. This panel was installed in 1982, and decommissioned in 2017. The system did continuous in alarm, as the panel had no coding options.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Edwards 439D-10AWC bells are original, and were on the 1527.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations were Edwards 274-111 conventional single-action pull stations. These were replaced when the system was upgraded, although it was conventional.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
This system pre-dated CFAA codes requiring smoke detectors, so there were none.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3346</id>
		<title>Marsden Hotel</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3346"/>
		<updated>2022-02-24T23:01:19Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Added year opened&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Fire-Lite Sensiscan 1000 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s &amp;lt;br /&amp;gt;Year Opened: 1926&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;The Marsden Hotel (The Fort Room)&#039;&#039;&#039; is a hotel and bar located in Marsden, SK. The year of construction is unknown. This building is currently for sale and has been for the past 3 years.&lt;br /&gt;
&lt;br /&gt;
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Fire-Lite Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous. It was installed in the 1980s, and is still in service.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of vintage unknown vibrating bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=%C3%89cole_Sam_Livingston_School&amp;diff=3340</id>
		<title>École Sam Livingston School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=%C3%89cole_Sam_Livingston_School&amp;diff=3340"/>
		<updated>2022-02-23T17:45:13Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Created Page: École Sam Livingston School&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!System Specifications&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|FACP: EST Quickstart QS1&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
System Type:Addressable/Hybrid&lt;br /&gt;
&lt;br /&gt;
System Line Voltage: 120VAC&lt;br /&gt;
&lt;br /&gt;
NAC Voltage:24VFWR&lt;br /&gt;
&lt;br /&gt;
Date of last known Upgrade: 2000s&lt;br /&gt;
&lt;br /&gt;
Year Opened: 1972&lt;br /&gt;
|}École Sam Livingston School is a CBE French immersion elementary school located in the community of Lake Bonavista. ThePurpleMage used to go to this school but no longer attends. It was built in 1972&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST Quickstart QS1 Addressable fire alarm control panel. The panel is located in the front entrance. When in alarm, this system does 120bpm March Time  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Edwards 439D-10AWC (10 inch) vibrating bells mounted on Edwards 403-5A-R strobe plates.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Edwards 270-SPO conventional single action pull station&lt;br /&gt;
&lt;br /&gt;
These pull stations are most likely conventional because of the triangle Edwards logo on the pull stations. These are most likely wired into EST SIGA CT-1 Monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic detection devices consist of EST SIGA PS addressable photoelectric smoke detectors&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3339</id>
		<title>Maple Ridge School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3339"/>
		<updated>2022-02-23T16:37:52Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4010 &amp;lt;br /&amp;gt;System Type:Addressable&amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 2015 &amp;lt;br /&amp;gt;Year Opened: 1976&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Maple Ridge School&#039;&#039;&#039; is an elementary school located in the Maple Ridge neighborhood of Southeast Calgary. The school has a capacity of approximately 600 students, and was built in 1967. The school received its most recent fire alarm upgrade in 2015.&lt;br /&gt;
==System Specifications (2015-present) ==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4010-9101C addressable fire alarm system. The panel is unconfirmed, as is the location. The system is on continuous for alarm, but the horns are self-coded. &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock MT-12/24-R multitone horns on Wheelock RSSP-24MCW-FR multi-candela strobe plates. These notification appliances were selected due to the large footprint of the previous devices, and to mount on the existing backboxes. The horns are set to code 3 horn (electromechanical), and the strobes are likely set on 15 candela. As with the panel, the locations of the devices are unknown.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9001 IDNet addressable pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex 4098-9714 IDNet addressable photoelectric smoke detectors located throughout the facility. They are likely set to 2% smoke/cubic foot.&lt;br /&gt;
==System Specifications (previous system, late 1980s-2015)==&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4002 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Decomissioned: 2015&lt;br /&gt;
|}&lt;br /&gt;
NOTE: This system is unconfirmed, as it is based off ThePurpleMage&#039;s memory, and the system at the neighboring [[R.T. Alderman School]].&lt;br /&gt;
====FACP====&lt;br /&gt;
The previous panel was likely a 16-zone Simplex 4002-8001 conventional fire alarm panel. The system likely did continuous in alarm.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The previous notification appliances were Simplex 2901-9833 mechanical horns on Simplex 2903-9101 strobe plates. &lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The previous pull stations were likely Simplex 2099-9901 &amp;quot;T-bar&amp;quot; conventional pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There were Simplex 2098-9110 ionization smoke detectors throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3338</id>
		<title>Marsden Hotel</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3338"/>
		<updated>2022-02-22T23:54:53Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Fire-Lite Sensiscan 1000 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s &amp;lt;br /&amp;gt;Year Opened: Unknown&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;The Marsden Hotel (The Fort Room)&#039;&#039;&#039; is a hotel and bar located in Marsden, SK. The year of construction is unknown. This building is currently for sale and has been for the past 3 years.&lt;br /&gt;
&lt;br /&gt;
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Fire-Lite Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous. It was installed in the 1980s, and is still in service.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of vintage unknown vibrating bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3335</id>
		<title>Marsden Hotel</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3335"/>
		<updated>2022-02-22T22:51:11Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Who thought that is was upgraded in 1990? and I specifically said that the year opened was unknown&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Honeywell Sensiscan 1000 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: Unknown&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;The Marsden Hotel (The Fort Room)&#039;&#039;&#039; is a hotel and bar located in Marsden, SK. The year of construction is unknown but the system appears to be from the mid 1960s. This building is currently for sale and has been for the past 3 years&lt;br /&gt;
&lt;br /&gt;
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous. &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3334</id>
		<title>Marsden Hotel</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3334"/>
		<updated>2022-02-22T22:45:38Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Fixed a fact oopsie&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Honeywell Sensiscan 1000 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 1990s? &amp;lt;br /&amp;gt;Year Opened: 1960s&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;The Marsden Hotel (The Fort Room)&#039;&#039;&#039; is a hotel and bar located in Marsden, SK. The year of construction is unknown but the system appears to be from the mid 1960s. This building is currently for sale and has been for the past 3 years&lt;br /&gt;
&lt;br /&gt;
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous. &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix of what appear to be Fire Lite BG-5 and Fire Lite BG-6 conventional single action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3320</id>
		<title>Marsden Hotel</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Marsden_Hotel&amp;diff=3320"/>
		<updated>2022-02-22T20:26:37Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Created Page: Marsden Hotel (The Fort Room)&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;The Marsden Hotel (The Fort Room)&#039;&#039;&#039; is a hotel and bar located in Marsden, SK&lt;br /&gt;
&lt;br /&gt;
The year of construction is unknown but the system appears to be from the mid 1960s.&lt;br /&gt;
&lt;br /&gt;
This building may be torn down in the near future as it is currently unowned and has been for 3 years&lt;br /&gt;
&lt;br /&gt;
Note: These specifications are as of 2017 and from the memory of user:ThePurpleMage&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Honeywell Senciscan 1000 conventional fire alarm control panel. The panel is located behind the front desk. When in alarm the system most likely does Steady code/Continuous  &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of Unknown Bells (possibly Honeywell, Grey in colour, 5 or 6 inch, has a label that says “Fire Bell 24V”).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of a mix of what appear to be Fire Lite BG5 and Fire Lite BG6 conventional single action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3319</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3319"/>
		<updated>2022-02-22T19:51:16Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: /* System Specifications */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;ThePurpleMage’s house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST IO-1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex 2901-9723 (6 inch) motor bells&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PCD addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3318</id>
		<title>Maple Ridge School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3318"/>
		<updated>2022-02-22T18:59:58Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4010 &amp;lt;br /&amp;gt;System Type:Addressable&amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 2015 &amp;lt;br /&amp;gt;Year Opened: 1976&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Maple Ridge School&#039;&#039;&#039; is an elementary school located in the Maple Ridge neighborhood of Southeast Calgary. The school has a capacity of approximately 600 students, and was built in 1967. The school received its most recent fire alarm upgrade in 2012.&lt;br /&gt;
==System Specifications (2015-present) ==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4010-9101C addressable fire alarm system. The panel is unconfirmed, as is the location. The system is on continuous for alarm, but the horns are self-coded. &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock MT-12/24-R multitone horns on Wheelock RSSP-24MCW-FR multi-candela strobe plates. These notification appliances were selected due to the large footprint of the previous devices, and to mount on the existing backboxes. The horns are set to code 3 horn (electromechanical), and the strobes are likely set on 15 candela. As with the panel, the locations of the devices are unknown.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9001 IDNet addressable pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex 4098-9714 IDNet addressable photoelectric smoke detectors located throughout the facility. They are likely set to 2% smoke/cubic foot.&lt;br /&gt;
==System Specifications (previous system, late 1980s-2015)==&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4002 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Decomissioned: 2015&lt;br /&gt;
|}&lt;br /&gt;
NOTE: This system is unconfirmed, as it is based off ThePurpleMage&#039;s memory, and the system at the neighboring [[R.T. Alderman School]].&lt;br /&gt;
====FACP====&lt;br /&gt;
The previous panel was likely a 16-zone Simplex 4002-8001 conventional fire alarm panel. The system likely did continuous in alarm.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The previous notification appliances were Simplex 2901-9833 mechanical horns on Simplex 2903-9101 strobe plates. &lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The previous pull stations were likely Simplex 2099-9901 &amp;quot;T-bar&amp;quot; conventional pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There were Simplex 2098-9110 ionization smoke detectors throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3317</id>
		<title>Maple Ridge School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Maple_Ridge_School&amp;diff=3317"/>
		<updated>2022-02-22T18:59:11Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Changed &amp;quot;Non User&amp;quot; to &amp;quot;ThePurpleMage&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4010 &amp;lt;br /&amp;gt;System Type:Addressable&amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: 2015 &amp;lt;br /&amp;gt;Year Opened: 1976&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Maple Ridge School&#039;&#039;&#039; is an elementary school located in the Maple Ridge neighborhood of Southeast Calgary. The school has a capacity of approximately 600 students, and was built in 1967. The school received its most recent fire alarm upgrade in 2012.&lt;br /&gt;
==System Specifications (2012-present) ==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4010-9101C addressable fire alarm system. The panel is unconfirmed, as is the location. The system is on continuous for alarm, but the horns are self-coded. &lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock MT-12/24-R multitone horns on Wheelock RSSP-24MCW-FR multi-candela strobe plates. These notification appliances were selected due to the large footprint of the previous devices, and to mount on the existing backboxes. The horns are set to code 3 horn (electromechanical), and the strobes are likely set on 15 candela. As with the panel, the locations of the devices are unknown.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9001 IDNet addressable pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex 4098-9714 IDNet addressable photoelectric smoke detectors located throughout the facility. They are likely set to 2% smoke/cubic foot.&lt;br /&gt;
==System Specifications (previous system, late 1980s-2012)==&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4002 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Decomissioned: 2015&lt;br /&gt;
|}&lt;br /&gt;
NOTE: This system is unconfirmed, as it is based off ThePurpleMage&#039;s memory, and the system at the neighboring [[R.T. Alderman School]].&lt;br /&gt;
====FACP====&lt;br /&gt;
The previous panel was likely a 16-zone Simplex 4002-8001 conventional fire alarm panel. The system likely did continuous in alarm.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The previous notification appliances were Simplex 2901-9833 mechanical horns on Simplex 2903-9101 strobe plates. &lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The previous pull stations were likely Simplex 2099-9901 &amp;quot;T-bar&amp;quot; conventional pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There were Simplex 2098-9110 ionization smoke detectors throughout the school.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3316</id>
		<title>ThePurpleMage&#039;s House</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ThePurpleMage%27s_House&amp;diff=3316"/>
		<updated>2022-02-22T18:54:43Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Added Page: ThePurpleMage&amp;#039;s House&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;ThePurpleMage’s house is a split level house in the community of Lake Bonavista. &lt;br /&gt;
&lt;br /&gt;
The house was built in 1973&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST IO-1000 Addressable fire alarm control panel. The panel is located in the boiler room. The panel replaced an Edwards 2280 in December of 2021&lt;br /&gt;
&lt;br /&gt;
When in alarm the system does Temporal code/code 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex 2901-9723 (6 inch) motor bells&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
The Automatic Detection Devices consist of EST SIGA PCD addressable smoke detectors.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Jack_Setters_Arena&amp;diff=3300</id>
		<title>Jack Setters Arena</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Jack_Setters_Arena&amp;diff=3300"/>
		<updated>2022-02-22T04:59:19Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: An extra space that was bugging me&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-300 &amp;lt;br /&amp;gt;System Type: Conventional &amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage:24VFWR&amp;lt;br /&amp;gt;Date of last known Upgrade: 2021 &amp;lt;br /&amp;gt;Year Opened: 1972&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Jack Setters Arena&#039;&#039;&#039; is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The facility is protected by a Mircom FA-300 Series Conventional fire alarm control panel. The panel is located in the main entrance. When in alarm the system most likely does steady code/continuous.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances consist of three Edwards 439D-10AWC (10 Inch) vibrating bells, located in the lobby, rink area, and the Zamboni room. In January 2021, an additional bell was installed, as confirmed by a permit was issued for &amp;quot;Fire Alarm System Modification - Add Fire Alarm Bell in Ammonia Room.&amp;quot; meaning that the fire alarm was either inaudible or too quiet. It is currently unknown what that bell is.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
There are three pull stations in this arena. Two of them are Edwards 270-SPOs. One is original and has the square shield, and the other is GE branded and was installed in the early 2010s. There is also a painted-over Notifier MPS-950B with a new sticker, which is a code violation as fire alarm devices cannot be painted. It is located under the scoreboard. [[User:ThePurpleMage|ThePurpleMage]] told the building manager about this issue, so the device will likely be replaced in the near future.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Jack_Setters_Arena&amp;diff=3257</id>
		<title>Jack Setters Arena</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Jack_Setters_Arena&amp;diff=3257"/>
		<updated>2022-02-22T01:57:43Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: Created page with &amp;quot;&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Jack Setters Arena&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972, ==System Specifications== ====FACP====...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;&#039;&#039;Jack Setters Arena&#039;&#039;&#039;&#039;&#039; is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972,&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The facility is protected by a Mircom FA-300 Series Conventional fire alarm control panel.  The panel is located in the main entrance. When in alarm the system most likely does steady code.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances consist of 3 Edwards Signaling 439D-10AW-R (10 Inch) vibrating bells, located in the lobby, rink area, and Zamboni room&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
There are 3 pull stations in this building, two of which are Edwards Signaling 270-SPO conventional pull stations and one Notifier MPS-950B conventional bilingual pull stations&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are no automatic detection devices that I could see in this building&lt;/div&gt;</summary>
		<author><name>ThePurpleMage</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Dr._Martha_Cohen_School&amp;diff=3256</id>
		<title>Dr. Martha Cohen School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Dr._Martha_Cohen_School&amp;diff=3256"/>
		<updated>2022-02-22T01:54:04Z</updated>

		<summary type="html">&lt;p&gt;ThePurpleMage: /* Pull Stations */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO500&amp;lt;br /&amp;gt;System Type:Addressable&amp;lt;br /&amp;gt; System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage:24VFWR&amp;lt;br /&amp;gt;Date of last known Upgrade: 2019&amp;lt;br /&amp;gt;Year Opened: 2017&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Dr. Martha Cohen School&#039;&#039;&#039; is a junior high school in the Calgary Board of Education. It is located in New Brighton, in SE Calgary, and has a capacity of about 900 students. It was built in 2017, and the system is original. It is known for having one of the loudest fire alarm systems in the whole district. &amp;lt;br&amp;gt;&lt;br /&gt;
[[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]] used to go here, but no longer attends.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The school is protected by an EST iO500 addressable fire alarm control panel. It is located in room #200 (second floor data room). This panel has had some issues in the past with false alarms, caused by a monitoring system error.&lt;br /&gt;
=====Annunciator=====&lt;br /&gt;
There is an EST RLCD-C LCD annunciator, as well as an EST RLED-24 LED annunciator, in the main entrance.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The notification appliances are from EST&#039;s &amp;quot;Genesis&amp;quot; line of products. The hallways have EST G1R-HDVM horn/strobes (red, wall mount, no FIRE), set on low volume, code 3. The classrooms have EST G1R-HD remote horns (red, wall mount, no FIRE). The bathrooms have EST G1R-VM remote strobes (red, wall, no FIRE), but the second floor men&#039;s restroom has a G1RF-VM (red, wall mount, FIRE lettering) remote strobe.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are EST SIGA-270 Signature-series addressable single-action pull stations. These are located in the hallways and the main office. Due to the potential of false alarms or damage, the pull stations in the gymnasiums, boiler rooms and wood shop have been replaced with Edwards MPSR1-SHTW hazardous-location pull stations, These are wired into EST SIGA-CT1 Signature-series monitor modules, as they are conventional.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS smoke detectors located throughout the school.&lt;/div&gt;</summary>