<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=TwentyThree33</id>
	<title>FireAlarmPedia - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=TwentyThree33"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php/Special:Contributions/TwentyThree33"/>
	<updated>2026-05-18T06:51:58Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Best_Western_Plus_Calgary_Centre_Inn&amp;diff=13775</id>
		<title>Best Western Plus Calgary Centre Inn</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Best_Western_Plus_Calgary_Centre_Inn&amp;diff=13775"/>
		<updated>2026-05-08T22:57:42Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Fuck brackets with nothing between them.  Also changed the sprinkler monitor module model as in 1999, they were likely using WTMs instead of CT1s.&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
|FACP: Edwards EST2&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Year Opened: 1999&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Best Western&#039;&#039;&#039; is a chain of hotels headquartered in Phoenix, Arizona. This particular hotel is located at 3630 Macleod Trail South, in Calgary, Alberta, Canada. The hotel was built in 1999, and the fire alarm system is original.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST2 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Edwards&#039; Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common areas have Edwards &amp;quot;Integrity&amp;quot; 757-5A-T horn/strobes (red, wall-mount, 15cd). &amp;lt;br&amp;gt;All guest rooms have Edwards 202-5A-T remote strobes (red, wall-mount, 15cd) paired with Edwards 683-1CR silenceable mini-horns (red).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell, mounted on EST SIGA-SB bases.&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;All signalling circuits utilize EST SIGA-MCC2 signal control modules.&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Hotels]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Best_Western_Plus_Calgary_Centre_Inn&amp;diff=13774</id>
		<title>Best Western Plus Calgary Centre Inn</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Best_Western_Plus_Calgary_Centre_Inn&amp;diff=13774"/>
		<updated>2026-05-08T22:54:03Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Did deficiency repairs here today, this page has been corrected and updated.  Fuck people who wire mini horn circuits with 14 gauge wire.&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST2&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Year Opened: 1999&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Best Western&#039;&#039;&#039; is a chain of hotels headquartered in Phoenix, Arizona. This particular hotel is located at 3630 Macleod Trail South, in Calgary, Alberta, Canada. The hotel was built in 1999, and the fire alarm system is original.&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST2 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Edwards&#039; Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common areas have Edwards &amp;quot;Integrity&amp;quot; 757-5A-T horn/strobes (red, wall-mount, 15cd). &amp;lt;br&amp;gt;All guest rooms have Edwards 202-5A-T remote strobes (red, wall-mount, 15cd) and Edwards 683-1CR silenceable mini-horns (red, wall-mount).&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell, mounted on EST SIGA-SB bases.&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;All signalling circuits utilize EST SIGA-MCC2 signal control modules.&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
[[]&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Hotels]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Deerfoot_Meadows_Building_800&amp;diff=13773</id>
		<title>Deerfoot Meadows Building 800</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Deerfoot_Meadows_Building_800&amp;diff=13773"/>
		<updated>2026-05-03T22:43:48Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2005 |}  &amp;#039;&amp;#039;&amp;#039;Deerfoot Meadows&amp;#039;&amp;#039;&amp;#039; is a shopping district in C...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2005&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Deerfoot Meadows&#039;&#039;&#039; is a shopping district in Calgary, Alberta, Canada.  This page will cover Building 800, located at #800 33 Heritage Meadows Way SE.  The building consists of Blossom Nails, Lindt Chocolate, Jerusalem Shawarma, Moores, Ethan Allen, and Petland.  The building was built in 2005, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST QuickStart QS1 addressable fire alarm system.  The panel is located in the main electrical room.  The system runs EST&#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Shopping Centres]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Deerfoot_Meadows_Building_8180&amp;diff=13772</id>
		<title>Deerfoot Meadows Building 8180</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Deerfoot_Meadows_Building_8180&amp;diff=13772"/>
		<updated>2026-05-03T22:43:35Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Boosters)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2004 |}  &amp;#039;&amp;#039;&amp;#039;Deerfoot Meadows&amp;#039;&amp;#039;&amp;#039;...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS1&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Boosters)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2004&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Deerfoot Meadows&#039;&#039;&#039; is a shopping district in Calgary, Alberta, Canada.  This page will cover Building 8180, located at 8180 11 St SE.  The building consists of Michaels, Penningtons, Couch9, Best Buy, Bouclair Calgary, Gap Factory, and EQ3.  The building was built in 2004, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
Please note that the FACP information is unconfirmed.  This page should not be used for official purposes.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST QuickStart QS1 addressable fire alarm system.  The panel is located in the main electrical room.  The system runs EST&#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are likely Edwards BPS6AC 6-amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Shopping Centres]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Calgary_Herald_Building&amp;diff=13771</id>
		<title>Calgary Herald Building</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Calgary_Herald_Building&amp;diff=13771"/>
		<updated>2026-05-03T22:43:23Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Hybrid-Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, Smokes&amp;lt;br /&amp;gt;Year Opened: 1980 |}  The &amp;#039;&amp;#039;&amp;#039;Calgary Herald Building&amp;#039;&amp;#039;&amp;#039; is a self-stor...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Hybrid-Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, Smokes&amp;lt;br /&amp;gt;Year Opened: 1980&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Calgary Herald Building&#039;&#039;&#039; is a self-storage facility owned by U-Haul.  The building is located at 215 16 St SE, in Calgary, Alberta, Canada.  The facility was built in 1980, and served as the head office for the Calgary Herald newspaper.  The fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 hybrid-addressable fire alarm system.  The panel is located in the main electrical room in the basement.  The system runs Edwards&#039; Signature addressable protocol, and utilizes a contactor to activate the bells.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is an Edwards EST3-LCDANN annunciator in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards &amp;quot;Durabel&amp;quot; 6000D vibrating bells (6&amp;quot; and 10&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Edwards 438D-6N5C and Siemens SFV120-6A vibrating bells (6&amp;quot; gong) as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are Edwards 270-GAO conventional two-stage single-action pull stations.  &amp;lt;br&amp;gt;Renovated areas have Edwards 270-SPO conventional single-action pull stations; these can also be found in other areas as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Edwards C2M-PD conventional photoelectric smoke detectors throughout the main atrium and at the top of each stairwell; System Sensor C2W-BA conventional photoelectric smoke detectors can also be found in these areas.  &amp;lt;br&amp;gt;There are conventional heat detectors in some areas, models unknown.  &amp;lt;br&amp;gt;There are Edwards SIGA-OSD addressable optical smoke detectors in the main elevator bank lobbies, mounted on Edwards SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all conventional and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Office Buildings]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Strathmore)&amp;diff=13770</id>
		<title>Walmart Supercentre (Strathmore)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Strathmore)&amp;diff=13770"/>
		<updated>2026-05-03T22:43:11Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2005 |}  &amp;#039;&amp;#039;&amp;#039;Walmart Supercentre&amp;#039;&amp;#039;&amp;#039; is a chain of hyper...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2005&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Walmart Supercentre&#039;&#039;&#039; is a chain of hypermarkets headquartered in Bentonville, Arkansas.  This particular store is located at 200 Ranch Market, in Strathmore, Alberta, Canada.  The building was built in 2005, and the fire alarm system is original excluding the FACP.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards iO1000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Edwards&#039; Signature addressable protocol, and the system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced an EST QuickStart QS1.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Some areas such as washrooms have Edwards G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Throughout the storefront, horn/strobes and strobes are mounted on poles in an alternating fashion.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising all kitchen suppression systems, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all kitchen suppression, sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Strathmore]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Sobeys_(Strathmore)&amp;diff=13769</id>
		<title>Sobeys (Strathmore)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Sobeys_(Strathmore)&amp;diff=13769"/>
		<updated>2026-05-03T22:42:59Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-350&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008 |}  &amp;#039;&amp;#039;&amp;#039;Sobeys&amp;#039;&amp;#039;&amp;#039; is a Canadian chain of grocery stores owned by Empi...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-350&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Sobeys&#039;&#039;&#039; is a Canadian chain of grocery stores owned by Empire.  This particular store is located at 100 Ranch Market, in Strathmore, Alberta, Canada.  The building was built in 2008, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-350 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s Alpha addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401ID addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-3100 addressable photoelectric smoke detectors at the top of each stairwell.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-100P addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-100R addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Strathmore]]&lt;br /&gt;
[[Category:Sobeys]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Airport_Corporate_Centre&amp;diff=13768</id>
		<title>Airport Corporate Centre</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Airport_Corporate_Centre&amp;diff=13768"/>
		<updated>2026-05-03T22:42:47Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4100+ Miniplex&amp;lt;br /&amp;gt;FACP Location: Basement Mezzanine Data Room&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Continuous (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2026, Module&amp;lt;br /&amp;gt;Year Opened: 1999 |}  &amp;#039;&amp;#039;&amp;#039;Airport Corpora...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100+ Miniplex&amp;lt;br /&amp;gt;FACP Location: Basement Mezzanine Data Room&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Continuous (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2026, Module&amp;lt;br /&amp;gt;Year Opened: 1999&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Airport Corporate Centre&#039;&#039;&#039; is an office building located at 1601 Airport Road NE, in Calgary, Alberta, Canada.  The building is owned by the Calgary Airport Authority, and is managed by GroupThree.  The building was built in 1999, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
Please note that this system is not connected to the [[Calgary International Airport]].&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4100+ Miniplex addressable fire alarm system.  The panel is located in the basement mezzanine data room.  The system runs Simplex&#039;s MAPNET II addressable protocol, and is configured for two-stage operation.  The alert signal coding is 20BPM, and the alarm signal coding is continuous.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are Simplex 4603-9101 annunciators in the main entrance vestibule and the IOC TV room.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There is a Simplex 4009 addressable booster power supply in the 2nd floor electrical room.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Simplex 2901-9724 motor bells (10&amp;quot; gong) mounted on Wheelock RSSP-2415W-FR strobe plates (red, 15cd).  &amp;lt;br&amp;gt;Some areas have GS/Edwards MB10-24 motor bells (10&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Edwards 439D-10AWC motor bells (10&amp;quot; gong) as deficiency replacements.  &amp;lt;br&amp;gt;Some areas have Simplex 2901-9723 motor bells (6&amp;quot; gong) mounted on Wheelock RSSP-24MCW-FR strobe plates (red, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 2099-9123C addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex 4098-9701C and Simplex 4098-9714 addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Simplex 4098-9731 addressable 135°F fixed-temperature/rate-of-rise heat detectors at the top of each elevator shaft.  &amp;lt;br&amp;gt;All older detectors are mounted on Simplex 2098-9651 bases, while all newer devices are mounted on Simplex 4098-9792 bases.  &amp;lt;br&amp;gt;There are Simplex 4098-9703 addressable photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Simplex 2190-9172C addressable monitor modules supervising the fire pump and generator&#039;s run/trouble contacts, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;One flow switch is supervised by a Simplex 4090-9001 addressable monitor module.  &amp;lt;br&amp;gt;There are Simplex 2190-9163 addressable relay modules serving various purposes.  &lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9039C end of line resistor plates on all signal circuits.  &amp;lt;br&amp;gt;There is a Simplex 2081-9040C end of line resistor plate on the sprinkler circuit supervised by the 4090-series module.  &amp;lt;br&amp;gt;All other monitored circuits utilize the internal EOLs on their monitor modules.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Office Buildings]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Vanier_Heights_A&amp;diff=13767</id>
		<title>Vanier Heights A</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Vanier_Heights_A&amp;diff=13767"/>
		<updated>2026-05-03T22:42:34Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Vanier Heights&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Vanier Heights&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building A, located at 2450A 22 Street, in Red Deer, Alberta, Canada.  The building was built in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).  &amp;lt;br&amp;gt;All suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500DMAPA addressable dual-input monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Red Deer]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Vanier_Heights_B&amp;diff=13766</id>
		<title>Vanier Heights B</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Vanier_Heights_B&amp;diff=13766"/>
		<updated>2026-05-03T22:42:23Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Vanier Heights&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Vanier Heights&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building B, located at 2450B 22 Street, in Red Deer, Alberta, Canada.  The building was built in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).  &amp;lt;br&amp;gt;All suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500DMAPA addressable dual-input monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Red Deer]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Lakecrest_Apartments&amp;diff=13765</id>
		<title>Lakecrest Apartments</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Lakecrest_Apartments&amp;diff=13765"/>
		<updated>2026-05-03T22:42:12Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020 |}  &amp;#039;&amp;#039;&amp;#039;Lakecrest Apartments&amp;#039;&amp;#039;&amp;#039; is an apartment building lo...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lakecrest Apartments&#039;&#039;&#039; is an apartment building located at 2 Crestview Blvd, in Sylvan Lake, Alberta, Canada.  The building is owned and operated by Broadstreet.  The building was built in 2020, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;All suite living areas have Mircom FS-400-WW remote strobes (white, wall-mount, set to 15cd); all suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500DMAPA addressable dual-input monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Sylvan Lake]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Castlebrook_Greens_A&amp;diff=13764</id>
		<title>Castlebrook Greens A</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Castlebrook_Greens_A&amp;diff=13764"/>
		<updated>2026-05-03T22:42:00Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Rear Exit&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020 |}  &amp;#039;&amp;#039;&amp;#039;Castlebrook Greens&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and op...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Rear Exit&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Castlebrook Greens&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building A, located at 17430 110 St NW, in Edmonton, Alberta, Canada.  The building was built in 2020, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located at the rear exit.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA-E horn/strobes (red, wall-mount, english lettering, set to 15cd).  &amp;lt;br&amp;gt;All suite bedrooms have System Sensor MHWZA silenceable mini-horns (white); all suite living rooms have System Sensor SWLA remote strobes (white, wall-mount, bilingual lettering, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====PulL Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors, and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the air handling unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M501MAPA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Broadstreet]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Castlebrook_Greens_B&amp;diff=13763</id>
		<title>Castlebrook Greens B</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Castlebrook_Greens_B&amp;diff=13763"/>
		<updated>2026-05-03T22:41:48Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020 |}  &amp;#039;&amp;#039;&amp;#039;Castlebrook Greens&amp;#039;&amp;#039;&amp;#039; is an apartment comple...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Castlebrook Greens&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building B, located at 17410 110 St NW, in Edmonton, Alberta, Canada.  The building was built in 2020, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA-E horn/strobes (red, wall-mount, english lettering, set to 15cd).  &amp;lt;br&amp;gt;All suite bedrooms have System Sensor MHWZA silenceable mini-horns (white).  &amp;lt;br&amp;gt;All suite living areas have System Sensor SWLA remote strobes (white, wall-mount, bilingual lettering, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There is a Mircom MIX-2351APA addressable photoelectric smoke detector in the 2nd floor electrical room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M501MAPA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Broadstreet]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Castlebrook_Greens_C&amp;diff=13762</id>
		<title>Castlebrook Greens C</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Castlebrook_Greens_C&amp;diff=13762"/>
		<updated>2026-05-03T22:41:37Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020 |}  &amp;#039;&amp;#039;&amp;#039;Castlebrook Greens&amp;#039;&amp;#039;&amp;#039; is an apartment comple...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Castlebrook Greens&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building C, located at 17420 110 St NW, in Edmonton, Alberta, Canada.  The building was built in 2020, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are four Mircom INX-10A addressable 10-amp booster power supplies in the 2nd floor electrical room.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA-E horn/strobes (red, wall-mount, english lettering, set to 15cd).  &amp;lt;br&amp;gt;All suite bedrooms have a mix of System Sensor MHWZA and Mircom MH-S25WA silenceable mini-horns (white).  &amp;lt;br&amp;gt;All suite living areas have System Sensor SWLA remote strobes (white, wall-mount, bilingual lettering, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M501MAPA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Broadstreet]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Laurel_Meadows_C&amp;diff=13761</id>
		<title>Laurel Meadows C</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Laurel_Meadows_C&amp;diff=13761"/>
		<updated>2026-05-03T22:41:11Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Laurel Meadows&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Laurel Meadows&#039;&#039;&#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Building C, located at 3203 18 Ave NW, in Edmonton, Alberta, Canada.  The building was built in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Mircom INX-10A addressable 10-amp booster power supplies on some floors.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).  &amp;lt;br&amp;gt;All suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors throughout all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HAPA addressable 190°F fixed-temperature heat detectors in the boiler room.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in the janitor room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500DMAPA addressable dual-input monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.   &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Broadstreet]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=8657_51_Ave_NW,_Edmonton,_AB&amp;diff=13760</id>
		<title>8657 51 Ave NW, Edmonton, AB</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=8657_51_Ave_NW,_Edmonton,_AB&amp;diff=13760"/>
		<updated>2026-05-03T22:40:57Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Kidde VS4&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982 |}  &amp;#039;&amp;#039;&amp;#039;8657 51 Ave NW&amp;#039;&amp;#039;&amp;#039; is the address of a small office bui...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Kidde VS4&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;8657 51 Ave NW&#039;&#039;&#039; is the address of a small office building in Edmonton, Alberta, Canada.  The building was built in 1982, and the fire alarm system was upgraded in the mid 2000s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2000s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Kidde VS4 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Kidde&#039;s GSA addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Edwards BPS10AC 10-amp booster power supplies in some electrical rooms.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Some areas have Edwards G1RF-HDVM horn/strobes (red, wall-mount, FIRE marking, set to 15cd) and Edwards G1AVWN horn/strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Some areas have Edwards GCAVWN horn/strobes (white, ceiling-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors in some areas, mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT2 addressable dual-input monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Office Buildings]]&lt;br /&gt;
[[Category:Kidde]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Lethbridge_South)&amp;diff=13759</id>
		<title>Walmart Supercentre (Lethbridge South)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Lethbridge_South)&amp;diff=13759"/>
		<updated>2026-05-03T22:40:45Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: South Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2001 |}  &amp;#039;&amp;#039;&amp;#039;Walmart Supercentre&amp;#039;&amp;#039;&amp;#039; is a chain of hypermarkets headquart...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: South Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2001&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Walmart Supercentre&#039;&#039;&#039; is a chain of hypermarkets headquartered in Bentonville, Arkansas, USA.  This particular store is located at 3700 Mayor Magrath Dr S, in Lethbridge, Alberta, Canada.  The building was built in 2001, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4100ES conventional fire alarm system.  The panel is located in the south entrance vestibule.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are a mix of System Sensor &amp;quot;SpectrAlert&amp;quot; P2415A, System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA, and System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, 15cd set or fixed).  &amp;lt;br&amp;gt;Some areas have a mix of System Sensor S2415A, SRA and SRLA remote strobes (red, wall-mount, 15cd set or fixed).  &amp;lt;br&amp;gt;Horn/strobes are located on all exterior walls, in the back stockroom, and in other areas; remote strobes are located in all washrooms.  Horn/strobes and strobes are mounted throughout the storefront on poles, mounted in an alternating fashion.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are a mix of Simplex MS-301C and Mircom MS-401 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9040C end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Walmart]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Lethbridge_North)&amp;diff=13758</id>
		<title>Walmart Supercentre (Lethbridge North)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Walmart_Supercentre_(Lethbridge_North)&amp;diff=13758"/>
		<updated>2026-05-03T22:40:32Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Left Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Booster)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2007 |}  &amp;#039;&amp;#039;&amp;#039;Walmart Supercen...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Left Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Booster)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2007&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Walmart Supercentre&#039;&#039;&#039; is a chain of hypermarkets headquartered in Bentonville, Arkansas, USA.  This particular store is located at 3055 26 Ave N, in Lethbridge, Alberta, Canada.  The building was built in 2007, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards iO1000 addressable fire alarm system.  The panel is located in the left entrance vestibule.  The system runs Edwards&#039; Signature addressable protocol, and the system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced an EST QuickStart QS1.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Edwards BPS6AC 6-amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Some areas, such as washrooms, have Edwards G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;Throughout the storefront, horn/strobes and strobes are mounted on poles in an alternating fashion.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising all kitchen suppression systems, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all kitchen suppression, sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Walmart]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Park_Place_Mall&amp;diff=13757</id>
		<title>Park Place Mall</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Park_Place_Mall&amp;diff=13757"/>
		<updated>2026-05-03T22:40:17Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST4&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2020&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1988 |}  &amp;#039;&amp;#039;&amp;#039;Park Place Mall&amp;#039;&amp;#039;&amp;#039; is a shoppin...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST4&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2020&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1988&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Park Place Mall&#039;&#039;&#039; is a shopping mall located at 501 1 Ave S, in Lethbridge, Alberta, Canada.  The mall is owned and operated by Primaris, and is the only enclosed shopping centre in Lethbridge.  The building was built in 1988, and the fire alarm system was upgraded in 2020.  &amp;lt;br&amp;gt;The original system was an Edwards Custom 6500 with EVAC.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2020-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST4 addressable fire alarm system.  This is a networked system with several nodes: the main node is located in the CACF room, and a node is located in the southwest entrance vestibule.  The system runs Edwards&#039; Signature addressable protocol, is equipped with voice evacuation, and is configured for two-stage operation.  The messages and/or tones are unknown at this time.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is an Edwards EST4-LCDANN annunciator in one entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards &amp;quot;Genesis&amp;quot; GCSVWF speaker/strobes (white, ceiling-mount, FIRE marking, set to 70V/15cd).  &amp;lt;br&amp;gt;Public areas of the mall have Edwards GCSWF remote speakers (white, ceiling-mount, FIRE marking, set to 70V) and Edwards G4SRF remote speakers (red, wall-mount, FIRE marking, set to 70V) for additional audible coverage.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Edwards SIGA-PD addressable photoelectric smoke detectors.  &amp;lt;br&amp;gt;There are Edwards SIGA-HRD addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on EST SIGA-SB bases.  &amp;lt;br&amp;gt;There are EST &amp;quot;SuperDuct&amp;quot; SIGA-SD addressable photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising all kitchen suppression systems, the generator&#039;s run/trouble contacts, the fire pump&#039;s run/trouble contacts, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-IM addressable isolator modules on all SLCs.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits supervised by monitor modules, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Malls]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=IHOP_(Lethbridge)&amp;diff=13756</id>
		<title>IHOP (Lethbridge)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=IHOP_(Lethbridge)&amp;diff=13756"/>
		<updated>2026-05-03T22:40:02Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4007ES&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2012 |}  &amp;#039;&amp;#039;&amp;#039;iHOP&amp;#039;&amp;#039;&amp;#039; (also known as International Hous...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4007ES&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2020s, FACP&amp;lt;br /&amp;gt;Year Opened: 2012&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;iHOP&#039;&#039;&#039; (also known as International House of Pancakes) is a breakfast-oriented restaurant chain.  This particular restaurant is located at 1818 Mayor Magrath Dr S, in Lethbridge, Alberta, Canada.  The building was built in 2012, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4007ES addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Simplex&#039;s IDNet addressable protocol, and the system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced a Simplex 4008.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Simplex &amp;quot;TrueAlert&amp;quot; 4906-9128 horn/strobes (red, ceiling-mount, set to 15cd).  &amp;lt;br&amp;gt;Some areas have Simplex 4906-9127 horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;All washrooms have Simplex 4906-9102 remote strobes (red, ceiling-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9001 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9733 addressable 135°F fixed-temperature/rate-of-rise heat detectors in the kitchen, mounted on Simplex 4098-9792 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is a Simplex 4090-9001 addressable monitor module supervising the kitchen suppression system.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9040C end of line resistor plates on the kitchen suppression system circuit, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Restaurants]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Logan_Boulet_Arena&amp;diff=13755</id>
		<title>Logan Boulet Arena</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Logan_Boulet_Arena&amp;diff=13755"/>
		<updated>2026-05-03T22:39:45Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards FireShield Plus FSP1004G&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: SIngle-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1960 |}  &amp;#039;&amp;#039;&amp;#039;Logan Boulet Arena&amp;#039;&amp;#039;&amp;#039; is an arena located at...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards FireShield Plus FSP1004G&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: SIngle-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1960&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Logan Boulet Arena&#039;&#039;&#039; is an arena located at 1302 9 Ave N, in Lethbridge, Alberta, Canada.  The arena is owned and operated by The City of Lethbridge.  The building was built in 1960, and the fire alarm system was upgraded in the 1980s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (1980s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards FireShield Plus FSP1004G conventional fire alarm system.  The panel is located in the main lobby.  The system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced an Edwards 2280 in the 2010s.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Integrity Powersaver&amp;quot; 757H-15PS horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are 135°F fixed-temperature/rate-of-rise heat detectors in some areas, likely System Sensor 5601A.  &amp;lt;br&amp;gt;There are high-temperature heat detectors in some areas such as the compressor room, likely System Sensor 5604A.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Arenas]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Cavendish_Farms_Centre&amp;diff=13754</id>
		<title>Cavendish Farms Centre</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Cavendish_Farms_Centre&amp;diff=13754"/>
		<updated>2026-05-03T22:39:34Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;29VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, IDNAC&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2019 |}  &amp;#039;&amp;#039;&amp;#039;Cavendish Farms Centre&amp;#039;&amp;#039;&amp;#039; is a r...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100ES&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;29VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, IDNAC&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2019&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Cavendish Farms Centre&#039;&#039;&#039; is a recreation centre located at 74 Mauretania Road W, in Lethbridge, Alberta, Canada.  The building was built in 2019, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4120 networked fire alarm system.  All nodes are Simplex 4100ES addressable fire alarm panels; Nodes 1-3 are located in the YMCA entrance vestibule, and Node 4 is located in the arena entrance vestibule.  The system runs Simplex&#039;s IDNet addressable initiating and IDNAC addressable indicating protocols, is equipped with voice evacuation, and is configured for two-stage operation.  The messages and/or tones are unknown at this time.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Simplex &amp;quot;TrueAlert ES&amp;quot; 49SV-APPLW addressable speaker/strobes equipped with 49SVC-WRFIRE covers (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;All lobbies, corridors and common areas have Simplex 49SO-APPLC addressable remote speakers equipped with 49SOC-CRFIRE covers (red, ceiling-mount).  &amp;lt;br&amp;gt;All areas with remote speakers have Simplex 49VO-WRF addressable remote strobes (red, wall-mount, set to 15cd); these can also be found in areas such as washrooms.  &amp;lt;br&amp;gt;For outdoor notification, there is a Simplex 49VO-WRFO-C weatherproof addressable remote strobe (red) outside the YMCA entrance.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9004CA addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9714 addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Simplex 4098-9733 addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Simplex 4098-9792 bases.  &amp;lt;br&amp;gt;There are Simplex 4098-9755 duct smoke detector housings equipped with Simplex 4098-9714 addressable photoelectric heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Firefighter&#039;s Telephones====&lt;br /&gt;
There are Simplex 2084-9107-C fire phones at all code-required locations.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Simplex 4090-9001 addressable monitor modules supervising all kitchen suppression systems, the generator&#039;s run/trouble contacts, the fire pump&#039;s run/trouble contacts, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Simplex 4090-9002 addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are Simplex 4090-9116 addressable isolator modules on all SLCs.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9040C end of line resistor plates on all circuits supervised by monitor modules, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Recreation]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Servus_Sports_Centre_Lethbridge&amp;diff=13753</id>
		<title>Servus Sports Centre Lethbridge</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Servus_Sports_Centre_Lethbridge&amp;diff=13753"/>
		<updated>2026-05-03T22:39:20Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-640C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1997 |}  &amp;#039;&amp;#039;&amp;#039;Servus Sports Centre Lethbridge&amp;#039;&amp;#039;&amp;#039; is an in...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS2-640C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, FACP&amp;lt;br /&amp;gt;Year Opened: 1997&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Servus Sports Centre Lethbridge&#039;&#039;&#039; is an indoor soccer facility located at 2501 28 Ave S, in Lethbridge, Alberta, Canada.  The facility is owned and operated by The City of Lethbridge.  The building was built in 1997, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS2-640C addressable fire alarm system.  The panel is located at the main entrance.  The system runs Notifier&#039;s CLIP addressable protocol, and the system coding is temporal.  &amp;lt;br&amp;gt;This panel replaced a Notifier AFP-400.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P2415A horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations, wired to Notifier MMX-101A addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier CPX-551A addressable ionization smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Notifier FDX-551RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All detectors are mounted on Notifier BX501 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier MMX-1A addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Recreation]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Spitz_Stadium&amp;diff=13752</id>
		<title>Spitz Stadium</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Spitz_Stadium&amp;diff=13752"/>
		<updated>2026-05-03T22:39:08Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4007ES&amp;lt;br /&amp;gt;FACP Location: CACF Room on Concourse&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync&amp;lt;br /&amp;gt;Date of last known Upgrade: 2017&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1977 |}  &amp;#039;&amp;#039;&amp;#039;Spitz Stadium&amp;#039;&amp;#039;&amp;#039; is a baseball stadium located at...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4007ES&amp;lt;br /&amp;gt;FACP Location: CACF Room on Concourse&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync&amp;lt;br /&amp;gt;Date of last known Upgrade: 2017&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1977&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Spitz Stadium&#039;&#039;&#039; is a baseball stadium located at 2425 Parkside Drive S, in Lethbridge, Alberta, Canada.  The stadium is home to the Lethbridge Bulls of the Western Canadian Baseball League (WCBL).  The stadium was built in 1977, and was renovated in 2017.  The fire alarm system was upgraded as part of the 2017 renovation.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2017-present)==&lt;br /&gt;
Please note that most system details are unconfirmed.  System research was conducted in February, and the stadium was not open at that time.  This page should not be used for official purposes.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Simplex 4007ES addressable fire alarm system.  The panel is located in the CACF room on the third base side of the concourse.  The system runs Simplex&#039;s IDNet addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All indoor notification appliances are Simplex &amp;quot;TrueAlert&amp;quot; 4906-9127 horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;The concourse and seating area have Simplex 4906-9131 weatherproof horn/strobes (red, wall-mount).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 4099-9004 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9714 addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Simplex 4098-9733 addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All detectors are mounted on Simplex 4098-9792 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Simplex 4090-9001 addressable monitor modules supervising all kitchen suppression systems.  &amp;lt;br&amp;gt;There are Simplex 4090-9002 addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Simplex 2081-9040C end of line resistor plates on all kitchen suppression and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Stadiums]]&lt;br /&gt;
[[Category:Simplex]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Excite_Lethbridge&amp;diff=13751</id>
		<title>Excite Lethbridge</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Excite_Lethbridge&amp;diff=13751"/>
		<updated>2026-05-03T22:38:50Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens Cerberus Pro Modular&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Temporal Tone + Message?&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2023...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens Cerberus Pro Modular&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Temporal Tone + Message?&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2023&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Excite Lethbridge&#039;&#039;&#039; is a convention centre located at 101 Exhibition Way S, in Lethbridge, Alberta, Canada.  The building was built in 2023, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Siemens Cerberus Pro Modular addressable fire alarm system.  The panel is located in the main electrical room.  The system runs Siemens&#039; FirePrint addressable protocol, and is equipped with voice evacuation.  The evacuation signal is likely a temporal tone with a pre-recorded message.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Siemens SE-MC-W-B speaker/strobes (white, wall-mount, bilingual lettering, set to 15cd).  &amp;lt;br&amp;gt;Some areas have Siemens SE-MC-CW-B speaker/strobes (white, ceiling-mount, bilingual lettering, set to 15cd).  &amp;lt;br&amp;gt;For outdoor notification, there is a Siemens ST-HMC-R-WP-B weatherproof remote strobe (red, bilingual lettering) outside the main electrical room.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Siemens M61-B conventional single-action pull stations, wired to Siemens XTRI-M addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Siemens OP921 addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Siemens OH921 addressable 135°F fixed-temperature/rate-of-rise heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Siemens DB-11 bases.  &amp;lt;br&amp;gt;There are Siemens FDBZ492-HR duct smoke detector housings equipped with Siemens OP921 addressable photoelectric heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Siemens XTRI-D addressable monitor modules supervising the generator&#039;s run/trouble contacts, the fire pump&#039;s run/trouble/not in auto contacts, and the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Siemens XTRI-R addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;All modules on this system have built-in isolators.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Siemens EL-300C end of line resistor plates on all circuits supervised by monitor modules, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Lethbridge]]&lt;br /&gt;
[[Category:Event Centres]]&lt;br /&gt;
[[Category:Siemens]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=4950_110_Ave_SE,_Calgary,_AB&amp;diff=13750</id>
		<title>4950 110 Ave SE, Calgary, AB</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=4950_110_Ave_SE,_Calgary,_AB&amp;diff=13750"/>
		<updated>2026-05-03T22:38:39Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: All Floors Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2011 |}  &amp;#039;&amp;#039;&amp;#039;4950 110 Ave SE&amp;#039;&amp;#039;&amp;#039; is the address of a small industria...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: All Floors Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2011&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;4950 110 Ave SE&#039;&#039;&#039; is the address of a small industrial plaza in Calgary, Alberta, Canada.  The plaza consists of All Floors, Dogsail Daycare, and SEGO.  The building was built in 2011, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the All Floors entrance vestibule.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340W horn/strobes (white, wall-mount, set to electromechanical/15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RBA addressable 135°F fixed-temperature/rate-of-rise heat detectors at the top of the elevator shaft and in the elevator machine room.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Arbour_Lake_Residents_Association&amp;diff=13749</id>
		<title>Arbour Lake Residents Association</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Arbour_Lake_Residents_Association&amp;diff=13749"/>
		<updated>2026-05-03T22:38:28Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1996 |}  The &amp;#039;&amp;#039;&amp;#039;Arbour Lake Residents Association&amp;#039;&amp;#039;&amp;#039; is a community centre...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1996&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Arbour Lake Residents Association&#039;&#039;&#039; is a community centre located at 12 Arbour Lake Dr NW, in Calgary, Alberta, Canada.  The building was built in 1996, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier System 500 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;Multi-Alert&amp;quot; MASS24LOA sounder/strobes (red, wall-mount, 1.5cd, set to tone).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are a mix of FDD CR-135 and System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in most areas.  &amp;lt;br&amp;gt;There are a mix of Edwards 245A and FDD CF-135 conventional 135°F fixed-temperature heat detectors in some areas.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Community Centres]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=2626_12_St_NE,_Calgary,_AB&amp;diff=13748</id>
		<title>2626 12 St NE, Calgary, AB</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=2626_12_St_NE,_Calgary,_AB&amp;diff=13748"/>
		<updated>2026-05-03T22:38:15Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mirtone MIR1-2Z3&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 1990s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1979, 1991 |}  &amp;#039;&amp;#039;&amp;#039;2626 12 St NE&amp;#039;&amp;#039;&amp;#039; is the address of an industrial building...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mirtone MIR1-2Z3&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 1990s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1979, 1991&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;2626 12 St NE&#039;&#039;&#039; is the address of an industrial building in the Vista Heights neighborhood of Calgary, Alberta, Canada.  The building was built in 1979, and was expanded in 1991.  The fire alarm system was upgraded in the 1990s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (1990s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mirtone MIR1-2Z3 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 439D-6AWC vibrating bells (6&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Edwards 439D-10AWC vibrating bells (10&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There is a System Sensor C2W-BA conventional photoelectric smoke detector at the top of the stairwell.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;br /&gt;
[[Category:Mirtone]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Chinook_Park_Condos&amp;diff=13747</id>
		<title>Chinook Park Condos</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Chinook_Park_Condos&amp;diff=13747"/>
		<updated>2026-05-03T22:38:02Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: None&amp;lt;br /&amp;gt;System Type: 120V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1970 |}  &amp;#039;&amp;#039;&amp;#039;Chinook Park Condos&amp;#039;&amp;#039;&amp;#039; is a condo building located at 507 57 Ave SW, in Calgary, Alberta, Canada.  The building was built in 1970, and the fire alarm system is mostly original...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: None&amp;lt;br /&amp;gt;System Type: 120V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1970&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Chinook Park Condos&#039;&#039;&#039; is a condo building located at 507 57 Ave SW, in Calgary, Alberta, Canada.  The building was built in 1970, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
The building is protected by a 120V hardwired fire alarm system, with bells and initiating devices wired in series-parallel.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Durabel&amp;quot; 6000D vibrating bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are American Sensors ESA5011 ionization smoke alarms throughout all corridors.  &amp;lt;br&amp;gt;There are Edwards 245A conventional 135°F fixed-temperature heat detectors in all mechanical, storage and laundry rooms.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Residential]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Best_Western_Village_Park_Inn&amp;diff=13746</id>
		<title>Best Western Village Park Inn</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Best_Western_Village_Park_Inn&amp;diff=13746"/>
		<updated>2026-05-03T22:37:52Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Service Hall behind Reception&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2014&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1981 |}  The &amp;#039;&amp;#039;&amp;#039;Best Western Village Par...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Service Hall behind Reception&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2014&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1981&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Best Western Village Park Inn&#039;&#039;&#039; is a hotel located at 1804 Crowchild Trail NW, in Calgary, Alberta, Canada.  The building was built in 1981, and the fire alarm system was upgraded in 2014.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2014-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the service hall behind the reception desk.  The system runs Notifier&#039;s FlashScan addressable protocol, and is configured for two-stage operation.  The alert signal coding is 20BPM, and the alarm signal coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Notifier KMS-6-24A motor bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier N-MPS-2A addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout all corridors and in some meeting rooms.  &amp;lt;br&amp;gt;There are Notifier FST-851RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in some meeting rooms, in all service elevator lobbies, and in some electrical rooms.  &amp;lt;br&amp;gt;There are Notifier FST-851HA addressable 190°F fixed-temperature heat detectors in all kitchens.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier XP6-MAA addressable zone cards supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier FRM-1A addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Hotels]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Bluebird_Self-Storage_(Dufferin)&amp;diff=13745</id>
		<title>Bluebird Self-Storage (Dufferin)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Bluebird_Self-Storage_(Dufferin)&amp;diff=13745"/>
		<updated>2026-05-03T22:37:40Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020 |}  &amp;#039;&amp;#039;&amp;#039;Bluebird Self-Storage&amp;#039;&amp;#039;&amp;#039; is a Calgary-based self-st...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2020&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Bluebird Self-Storage&#039;&#039;&#039; is a Calgary-based self-storage chain.  This particular facility is located at 5411 Dufferin Blvd SE, in Calgary, Alberta, Canada.  The building was built in 2020, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors at the top of each stairwell, in each elevator lobby, and at the top of each elevator shaft, mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There are System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housings equipped with Mircom MIX-2251APA addressable photoelectric heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Self-Storage]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Lakeside_Estates_Building_A&amp;diff=13744</id>
		<title>Lakeside Estates Building A</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Lakeside_Estates_Building_A&amp;diff=13744"/>
		<updated>2026-05-03T22:37:28Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Floor Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2018&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1971 |}  &amp;#039;&amp;#039;&amp;#039;Lakeside Estates&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and o...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Floor Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2018&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1971&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lakeside Estates&#039;&#039;&#039; is an apartment complex owned and operated by Boardwalk.  This page will cover Building A, located at 5332 Lakeview Drive SW, in Calgary, Alberta, Canada.  The building was built in 1971, and the fire alarm system was upgraded in 2018.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2018-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main floor electrical room.  The system runs Mircom&#039;s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are Mircom RAX-LCD annunciators paired with Mircom RAX-1048TZDS annunciators in all entrance vestibules.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Mircom BL-10B motor bells (10&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Mircom BL-6B motor bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors in all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all laundry, mechanical and electrical rooms.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Boardwalk]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Lakeside_Estates_Building_B&amp;diff=13743</id>
		<title>Lakeside Estates Building B</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Lakeside_Estates_Building_B&amp;diff=13743"/>
		<updated>2026-05-03T22:37:16Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Floor Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2018&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1971 |}  &amp;#039;&amp;#039;&amp;#039;Lakeside Estates&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and o...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Floor Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2018&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1971&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lakeside Estates&#039;&#039;&#039; is an apartment complex owned and operated by Boardwalk.  This page will cover Building B, located at 5334 Lakeview Dr SW, in Calgary, Alberta, Canada.  The building was built in 1971, and the fire alarm system was upgraded in 2018.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2018-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the main floor electrical room.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are Mircom RAX-LCD annunciators paired with Mircom RAX-1048TZDS annunciators in all entrance vestibules.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Mircom BL-10B motor bells (10&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Mircom BL-6B motor bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors in all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Mircom MIX-5251RAPA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all laundry, mechanical and electrical rooms.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Boardwalk]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Prominence_Place_Building_A&amp;diff=13742</id>
		<title>Prominence Place Building A</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Prominence_Place_Building_A&amp;diff=13742"/>
		<updated>2026-05-03T22:37:04Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1983 |}  &amp;#039;&amp;#039;&amp;#039;Prominence Place&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and operated by Bo...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1983&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Prominence Place&#039;&#039;&#039; is an apartment complex owned and operated by Boardwalk.  This page will cover Building A, located at 401 Patterson Hill SW, in Calgary, Alberta, Canada.  The building was built in 1983, and the fire alarm system is partially original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom BL-6B motor bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors in all corridors and at the top of each stairwell.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in all laundry and electrical rooms.  &amp;lt;br&amp;gt;There are FDD CF-200 conventional 200°F fixed-temperature heat detectors in the boiler room.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Boardwalk]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Centre_58&amp;diff=13741</id>
		<title>Centre 58</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Centre_58&amp;diff=13741"/>
		<updated>2026-05-03T22:36:52Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards FireShield Plus FSP1004G&amp;lt;br /&amp;gt;FACP Location: Oriental Phoenix Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2021, FACP&amp;lt;br /&amp;gt;Year Opened: 1953 |}  &amp;#039;&amp;#039;&amp;#039;Centre 58&amp;#039;...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards FireShield Plus FSP1004G&amp;lt;br /&amp;gt;FACP Location: Oriental Phoenix Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2021, FACP&amp;lt;br /&amp;gt;Year Opened: 1953&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Centre 58&#039;&#039;&#039; is a retail complex located at 104 58 Ave SW, in Calgary, Alberta, Canada.  The complex consists of Value Village and Oriental Phoenix.  The building was built in 1953, and the fire alarm system was upgraded in the 2000s, with an FACP replacement occurring in 2021.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2000s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards FireShield Plus FSP1004G conventional fire alarm system.  The panel is located in the Oriental Phoenix entrance vestibule.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are Notifier NFM-950B conventional single-action pull stations.  &amp;lt;br&amp;gt;Some areas have Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in all restaurant storage rooms.  &amp;lt;br&amp;gt;There are a mix of Edwards 245A conventional 135°F fixed-temperature heat detectors and FDD CF-200 conventional 200°F fixed-temperature heat detectors in the restaurant kitchens.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Restaurants]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Bowness_Scout_Hall&amp;diff=13740</id>
		<title>Bowness Scout Hall</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Bowness_Scout_Hall&amp;diff=13740"/>
		<updated>2026-05-03T22:36:39Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2012 |}  The &amp;#039;&amp;#039;&amp;#039;Bowness Scout Hall&amp;#039;&amp;#039;&amp;#039; is a scout hall located at...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2012&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Bowness Scout Hall&#039;&#039;&#039; is a scout hall located at 8551 Bowness Road NW, in Calgary, Alberta, Canada.  The building was built in 2012, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located at the main entrance.  The system runs Notifier&#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout most areas.  &amp;lt;br&amp;gt;There are Notifier FST-851RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all kitchens, and all storage and mechanical rooms.  &amp;lt;br&amp;gt;All detectors are mounted on Notifier B710LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is a Notifier FMM-1A addressable monitor module supervising the kitchen suppression system.  &amp;lt;br&amp;gt;There is a Notifier FRM-1A addressable relay module for furnace shutdown.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Community Centres]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Brentwood_Sportsplex&amp;diff=13739</id>
		<title>Brentwood Sportsplex</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Brentwood_Sportsplex&amp;diff=13739"/>
		<updated>2026-05-03T22:36:27Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2026, Duct Smokes&amp;lt;br /&amp;gt;Year Opened: 1976 |}  The &amp;#039;&amp;#039;&amp;#039;Brentwood Sportsplex&amp;#039;&amp;#039;&amp;#039; is a sports complex located...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 1980s&amp;lt;br /&amp;gt;Most Recent Known Modification: 2026, Duct Smokes&amp;lt;br /&amp;gt;Year Opened: 1976&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Brentwood Sportsplex&#039;&#039;&#039; is a sports complex located at 1520B Northmount Drive NW, in Calgary, Alberta, Canada.  The building consists of an arena, an event space, and a daycare.  The building was built in 1976, and the fire alarm system was upgraded in the 1980s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (1980s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel is located in the main lobby.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 439D-6AWC vibrating bells (6&amp;quot; gong).  &amp;lt;br&amp;gt;Some areas have Edwards 439D-10AWC vibrating bells (10&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are Edwards 270-SPO conventional single-action pull stations.  &amp;lt;br&amp;gt;Some areas have Mircom MS-401 conventional single-action pull stations as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors in the lobby, at the top of each stairwell, and at the top of the elevator shaft.  &amp;lt;br&amp;gt;There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in all storage, compressor, mechanical and janitor rooms.  &amp;lt;br&amp;gt;There are System Sensor 5604A conventional 194°F fixed-temperature heat detectors in all furnace rooms.  &amp;lt;br&amp;gt;There are Edwards &amp;quot;SuperDuct&amp;quot; SD-2W conventional photoelectric duct smoke detectors on the 2nd floor furnaces.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Arenas]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Brentwood_Community_Centre&amp;diff=13738</id>
		<title>Brentwood Community Centre</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Brentwood_Community_Centre&amp;diff=13738"/>
		<updated>2026-05-03T22:36:06Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: None&amp;lt;br /&amp;gt;System Type: 120V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: 1972&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965 |}  &amp;#039;&amp;#039;&amp;#039;Brentwood Community Centre&amp;#039;&amp;#039;&amp;#039; is a community centre located at 5107 33 St NW, in Calgary, Alberta, Canada.  The building was built in 1965, and was expanded in 1972.  The fir...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: None&amp;lt;br /&amp;gt;System Type: 120V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: 1972&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Brentwood Community Centre&#039;&#039;&#039; is a community centre located at 5107 33 St NW, in Calgary, Alberta, Canada.  The building was built in 1965, and was expanded in 1972.  The fire alarm system was installed as part of the 1972 expansion.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
The building is protected by a 120V hardwired fire alarm system, with bells and initiating devices wired in series-parallel.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The only notification appliance is an Edwards &amp;quot;Durabel&amp;quot; 6000D vibrating bell (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Edwards 281C conventional 135°F fixed-temperature/rate-of-rise heat detectors in the furnace and storage rooms.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Community Centres]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Lynwood_Learning_Centre&amp;diff=13737</id>
		<title>Lynwood Learning Centre</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Lynwood_Learning_Centre&amp;diff=13737"/>
		<updated>2026-05-03T22:35:44Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1025T&amp;lt;br /&amp;gt;FACP Location: Centre West Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2020&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1975 |}  The &amp;#039;&amp;#039;&amp;#039;Lynwood Learning Centre&amp;#039;&amp;#039;&amp;#039; is a preschool and day...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1025T&amp;lt;br /&amp;gt;FACP Location: Centre West Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2020&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1975&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Lynwood Learning Centre&#039;&#039;&#039; is a preschool and daycare located at 1A, 7005 18 St SE, in Calgary, Alberta, Canada.  The building was built in 1975, and the fire alarm system was installed in 2020.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2020-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1025T conventional fire alarm system.  The panel is located in the centre west electrical room.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Summit SPS-101CA conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors in most areas.  &amp;lt;br&amp;gt;There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in some areas.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Childcare]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Calgary_Christian_Elementary_School&amp;diff=13736</id>
		<title>Calgary Christian Elementary School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Calgary_Christian_Elementary_School&amp;diff=13736"/>
		<updated>2026-05-03T22:35:33Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier AFP-200&amp;lt;br /&amp;gt;FACP Location: South Stairwell&amp;lt;br /&amp;gt;System Type: Single-Stage Hybrid-Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2004&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1963, 1974, 1978, 1993 |}  &amp;#039;&amp;#039;&amp;#039;Calgary Christian Elementary School&amp;#039;&amp;#039;&amp;#039; is...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier AFP-200&amp;lt;br /&amp;gt;FACP Location: South Stairwell&amp;lt;br /&amp;gt;System Type: Single-Stage Hybrid-Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2004&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1963, 1974, 1978, 1993&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Calgary Christian Elementary School&#039;&#039;&#039; is a Christian elementary school located at 5029 26 Ave SW, in Calgary, Alberta, Canada.  The building was built in 1963, was expanded in 1974 and 1978, and had portable classrooms added in 1993.  The fire alarm system was upgraded in 2004.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2004-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier AFP-200 hybrid-addressable fire alarm system.  The panel is located in the south stairwell.  The system runs Notifier&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P1224MCA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;Some areas have System Sensor S1224MCA remote strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;All portables have Notifier KMS-6-24A motor bells (6&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations.  &amp;lt;br&amp;gt;These are wired to Notifier FMM-101A addressable monitor modules in the main building.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSI-851A addressable ionization smoke detectors in the main office and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Notifier FST-851RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all locker, storage and mechanical rooms.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Notifier B710LPA bases.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in all portables.  &amp;lt;br&amp;gt;There is a Notifier FSD-751PLA addressable photoelectric duct smoke detector on the air handling unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is a Notifier FMM-1A addressable monitor module supervising the kitchen suppression system.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all conventional and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Education]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Calgary_Christian_High_School&amp;diff=13735</id>
		<title>Calgary Christian High School</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Calgary_Christian_High_School&amp;diff=13735"/>
		<updated>2026-05-03T22:35:21Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Basement Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: 2008&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965, 1977, 2001 |}  &amp;#039;&amp;#039;&amp;#039;Calgary Christian High Schoo...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Basement Electrical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: 2008&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965, 1977, 2001&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Calgary Christian High School&#039;&#039;&#039; is a high school located at 5029 26 Ave SW, in Calgary, Alberta, Canada.  The building was built in 1965, and was expanded in 1977 and 2001.  The fire alarm system was upgraded in 2008.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2008-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the basement electrical room.  The system runs Notifier&#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Notifier LCD-80 annunciator at the main entrance.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;All washrooms have System Sensor SRA remote strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSI-851A addressable ionization smoke detectors in all stairwells, the electrical room, and the recording studio.  &amp;lt;br&amp;gt;There are Notifier FST-851RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in all locker, storage and art rooms, and in the garage.  &amp;lt;br&amp;gt;There are Notifier FST-851HA addressable 190°F fixed-temperature heat detectors in all mechanical rooms.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Notifier B710LPA bases.  &amp;lt;br&amp;gt;There is an FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detector in the home ec room, wired to a Notifier FMM-101A addressable monitor module.  &amp;lt;br&amp;gt;There are Notifier &amp;quot;Innovair&amp;quot; FSD-751PLA addressable photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is a Notifier FMM-1A addressable monitor module supervising the kitchen suppression system.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on the kitchen suppression system circuit, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Education]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Calgary_Golf_%26_Country_Club&amp;diff=13734</id>
		<title>Calgary Golf &amp; Country Club</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Calgary_Golf_%26_Country_Club&amp;diff=13734"/>
		<updated>2026-05-03T22:35:10Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2003&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965 |}  The &amp;#039;&amp;#039;&amp;#039;Calgary Golf &amp;amp; Country Club&amp;#039;&amp;#039;&amp;#039; is a golf and country club located...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2003&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1965&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Calgary Golf &amp;amp; Country Club&#039;&#039;&#039; is a golf and country club located at 909 50 Ave SW, in Calgary, Alberta, Canada.  The building was built in 1965, and the fire alarm system was upgraded in 2003.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2003-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located at the main entrance.  The system runs Mircom&#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All indoor notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-240R horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;For outdoor notification, there is a Mircom weatherproof remote strobe outside the main entrance (model unknown).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There is a Mircom MIX-5251BA addressable 135°F fixed-temperature heat detector in the mechanical room, mounted on a System Sensor B210LPA base.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Recreation]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=The_Care_Group_Calgary&amp;diff=13733</id>
		<title>The Care Group Calgary</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=The_Care_Group_Calgary&amp;diff=13733"/>
		<updated>2026-05-03T22:34:58Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST2&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: 2002&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1947 |}  &amp;#039;&amp;#039;&amp;#039;The Care Group Calgary&amp;#039;&amp;#039;&amp;#039; is a health services company locat...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST2&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: 2002&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1947&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;The Care Group Calgary&#039;&#039;&#039; is a health services company located at 1318 Centre St NW, in Calgary, Alberta, Canada.  The building was built in 1947, and the fire alarm system was upgraded in 2002.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2002-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST2 addressable fire alarm system.  The panel is located at the main entrance.  The system runs Edwards&#039; Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Integrity&amp;quot; 757-5A-T horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors at the top of each stairwell.  &amp;lt;br&amp;gt;There are EST SIGA-HFS addressable 135°F fixed-temperature heat detectors in all electrical and furnace rooms.  &amp;lt;br&amp;gt;All detectors are mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system&#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Healthcare]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Traxx_Coachlines_(Airdrie)&amp;diff=13732</id>
		<title>Traxx Coachlines (Airdrie)</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Traxx_Coachlines_(Airdrie)&amp;diff=13732"/>
		<updated>2026-05-03T22:34:47Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008 |}  &amp;#039;&amp;#039;&amp;#039;Traxx Coachlines&amp;#039;&amp;#039;&amp;#039; is a transportation company.  This page will cove...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Traxx Coachlines&#039;&#039;&#039; is a transportation company.  This page will cover the Airdrie location, located at #105, 2874 Kingsview Blvd SE, in Airdrie, Alberta, Canada.  The building was built in 2008, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-240R horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors at the top of each stairwell.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Airdrie]]&lt;br /&gt;
[[Category:Transportation]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=38_Inverness_Square_SE,_Calgary,_AB&amp;diff=13731</id>
		<title>38 Inverness Square SE, Calgary, AB</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=38_Inverness_Square_SE,_Calgary,_AB&amp;diff=13731"/>
		<updated>2026-05-03T22:34:32Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1998 |}  &amp;#039;&amp;#039;&amp;#039;38 Inverness Square SE&amp;#039;&amp;#039;&amp;#039; is the address of a small walkup apart...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1998&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;38 Inverness Square SE&#039;&#039;&#039; is the address of a small walkup apartment building in the McKenzie Towne neighborhood of Calgary, Alberta, Canada.  The building was built in 1998, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
Please note that most system information is unconfirmed, as available information is limited.  This page should not be used for official purposes.&lt;br /&gt;
&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier System 500 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P2415A horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors in all corridors.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in the crawlspace, and in all storage and electrical rooms.  &amp;lt;br&amp;gt;There are FDD CF-200 conventional 200°F fixed-temperature heat detectors in the mechanical room.  &amp;lt;br&amp;gt;There are System Sensor &amp;quot;Innovair Flex&amp;quot; D2A conventional photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Lynn_Apartments&amp;diff=13730</id>
		<title>Lynn Apartments</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Lynn_Apartments&amp;diff=13730"/>
		<updated>2026-05-03T22:34:19Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: None&amp;lt;br /&amp;gt;System Type: 24V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 24VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, Pulls&amp;lt;br /&amp;gt;Year Opened: 1958 |}  &amp;#039;&amp;#039;&amp;#039;Lynn Apartments&amp;#039;&amp;#039;&amp;#039; is an apartment building located at 126 13 Ave NW, in Calgary, Alberta, Canada.  The building was built in 1958, and the fire alarm system is mostly...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: None&amp;lt;br /&amp;gt;System Type: 24V Hardwired&amp;lt;br /&amp;gt;System Line Voltage: 24VAC&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, Pulls&amp;lt;br /&amp;gt;Year Opened: 1958&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Lynn Apartments&#039;&#039;&#039; is an apartment building located at 126 13 Ave NW, in Calgary, Alberta, Canada.  The building was built in 1958, and the fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
The building is protected by a 24VAC hardwired fire alarm system, with bells and initiating devices wired in series-parallel.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
There is one notification appliance on this system, an Edwards &amp;quot;Adaptahorn&amp;quot; 374 remote horn.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Summit SPS-101CA conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are American Sensors ESA5011 ionization smoke alarms in all corridors.  &amp;lt;br&amp;gt;There are a mix of Edwards 281C conventional 135°F fixed-temperature/rate-of-rise and Edwards 245A conventional 135°F fixed-temperature heat detectors in the storage, laundry and boiler rooms.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Residential]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Chiniki_College&amp;diff=13729</id>
		<title>Chiniki College</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Chiniki_College&amp;diff=13729"/>
		<updated>2026-05-03T22:34:06Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2003 |}  &amp;#039;&amp;#039;&amp;#039;Chiniki College&amp;#039;&amp;#039;&amp;#039; is a post-secondary institution l...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2003&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Chiniki College&#039;&#039;&#039; is a post-secondary institution located in Morley, Alberta, Canada.  The building was built in 2003, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located at the main entrance.  The system runs Notifier&#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P2415A horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Notifier FST-751RA addressable 135°F fixed-temperature/rate-of-rise heat detectors in most areas.  &amp;lt;br&amp;gt;All detectors are mounted on Notifier B710LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;
[[Category:Education]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Edgemont_Retirement_Centre&amp;diff=13728</id>
		<title>Edgemont Retirement Centre</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Edgemont_Retirement_Centre&amp;diff=13728"/>
		<updated>2026-05-03T22:33:55Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier System 5000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1997 |}  The &amp;#039;&amp;#039;&amp;#039;Edgemont Retirement Centre&amp;#039;&amp;#039;&amp;#039; is a retirement home located...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier System 5000&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1997&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;Edgemont Retirement Centre&#039;&#039;&#039; is a retirement home located at 80 Edenwold Dr NW, in Calgary, Alberta, Canada.  The building was built in 1997, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier System 5000 conventional fire alarm system.  The panel is located at the main entrance.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P2415WA horn/strobes (white, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors throughout all corridors, and at the top of each stairwell.  &amp;lt;br&amp;gt;There are System Sensor &amp;quot;Innovair Flex&amp;quot; D2A conventional photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=McKenzie_Towne_Retirement_Residence&amp;diff=13727</id>
		<title>McKenzie Towne Retirement Residence</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=McKenzie_Towne_Retirement_Residence&amp;diff=13727"/>
		<updated>2026-05-03T22:33:43Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Mechanical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Boosters)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2002 |}  The &amp;#039;&amp;#039;&amp;#039;McKenzie Towne Retiremen...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Mechanical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR (FACP)&amp;lt;br&amp;gt;24VDC (Boosters)&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2002&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;McKenzie Towne Retirement Residence&#039;&#039;&#039; is a retirement home located at 20 Promenade Park SE, in Calgary, Alberta, Canada.  The building was built in 2002, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards iO1000 conventional fire alarm system.  The panel is located in the mechanical room.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Edwards BPS6AC 6-amp booster power supplies in the 2nd and 3rd floor janitor rooms.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Edwards &amp;quot;Integrity&amp;quot; 757-5A-T horn/strobes (red, wall-mount, 15cd).  &amp;lt;br&amp;gt;All suites have Edwards 683-1C silenceable mini-horns (white) paired with Edwards 202-5A-T remote strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors throughout all corridors.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors at the top of each elevator shaft, and in the transfer switch room.  &amp;lt;br&amp;gt;There are Edwards &amp;quot;SuperDuct&amp;quot; SD-2W conventional photoelectric duct smoke detectors on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Daydream_Daycare&amp;diff=13726</id>
		<title>Daydream Daycare</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Daydream_Daycare&amp;diff=13726"/>
		<updated>2026-05-03T22:33:30Z</updated>

		<summary type="html">&lt;p&gt;TwentyThree33: Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST iO500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: Late 1950s |}  &amp;#039;&amp;#039;&amp;#039;Daydream Daycare&amp;#039;&amp;#039;&amp;#039; is a daycare located at 329 3 Ave SE,...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: Late 1950s&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Daydream Daycare&#039;&#039;&#039; is a daycare located at 329 3 Ave SE, in High River, Alberta, Canada.  The building&#039;s year of construction is unknown, but is assumed to be sometime in the 1950s as homes in the area were built in 1956.  The fire alarm system was upgraded in the 2010s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2010s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST iO500 addressable fire alarm system.  The panel is located at the main entrance.  The system runs EST&#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors throughout most areas, mounted on EST SIGA-SB bases.  &amp;lt;br&amp;gt;There are Edwards 281B-PL conventional 135°F fixed-temperature/rate-of-rise heat detectors in the kitchen, and the electrical and furnace rooms, wired to EST SIGA-CT1 addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:High River]]&lt;br /&gt;
[[Category:Childcare]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>