<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=%C3%89cole_Secondaire_du_Sommet</id>
	<title>École Secondaire du Sommet - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=%C3%89cole_Secondaire_du_Sommet"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=%C3%89cole_Secondaire_du_Sommet&amp;action=history"/>
	<updated>2026-09-04T05:01:22Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=%C3%89cole_Secondaire_du_Sommet&amp;diff=13885&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS&lt;br /&gt;FACP Location: Unknown&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Siemens&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2010 |}  &#039;&#039;&#039;École Secondaire du Sommet&#039;&#039;&#039; is a secondary school locate...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=%C3%89cole_Secondaire_du_Sommet&amp;diff=13885&amp;oldid=prev"/>
		<updated>2026-09-03T23:42:38Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS&amp;lt;br /&amp;gt;FACP Location: Unknown&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2010 |}  &amp;#039;&amp;#039;&amp;#039;École Secondaire du Sommet&amp;#039;&amp;#039;&amp;#039; is a secondary school locate...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens FireFinder XLS&amp;lt;br /&amp;gt;FACP Location: Unknown&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2010&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;École Secondaire du Sommet&amp;#039;&amp;#039;&amp;#039; is a secondary school located at 500 Larry Uteck Blvd, in Halifax, Nova Scotia, Canada.  The building was built in 2010, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Siemens FireFinder XLS addressable fire alarm system.  The panel location is unknown.  The system runs Siemens&amp;#039; FirePrint addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Siemens ZH-MC-R-B horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Siemens HMS-SA addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Siemens HFP-11 addressable multisensor smoke/heat detectors throughout the building, mounted on Siemens DB-11 bases.  &amp;lt;br&amp;gt;There are Siemens FDBZ492-HR duct smoke detector housings equipped with Siemens HFP-11 addressable heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Siemens HTRI-D addressable dual-input monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Siemens HTRI-R addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Siemens EL-300C end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Credits==&lt;br /&gt;
Thank you to NSS for submitting this system!&lt;br /&gt;
&lt;br /&gt;
[[Category:Nova Scotia]]&lt;br /&gt;
[[Category:Education]]&lt;br /&gt;