<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=10555_74_St_SE%2C_Calgary%2C_AB</id>
	<title>10555 74 St SE, Calgary, AB - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=10555_74_St_SE%2C_Calgary%2C_AB"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=10555_74_St_SE,_Calgary,_AB&amp;action=history"/>
	<updated>2026-04-07T07:29:53Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=10555_74_St_SE,_Calgary,_AB&amp;diff=13342&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&lt;br /&gt;FACP Location: Main Mechanical Room&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, System Sensor&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2019 |}   &#039;&#039;&#039;10555 74 St SE&#039;&#039;&#039; is the address of a small...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=10555_74_St_SE,_Calgary,_AB&amp;diff=13342&amp;oldid=prev"/>
		<updated>2025-09-05T01:41:47Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Mechanical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2019 |}   &amp;#039;&amp;#039;&amp;#039;10555 74 St SE&amp;#039;&amp;#039;&amp;#039; is the address of a small...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C&amp;lt;br /&amp;gt;FACP Location: Main Mechanical Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2019&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;10555 74 St SE&amp;#039;&amp;#039;&amp;#039; is the address of a small industrial plaza in the Point Trotter Industrial district of Calgary, Alberta, Canada.  The building was built in 2019, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the main mechanical room.  The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd).  &amp;lt;br&amp;gt;There are System Sensor PC2RLA horn/strobes (red, ceiling-mount, bilingual lettering, set to 15cd) in the warehouse areas of Units 120 and 130.  &amp;lt;br&amp;gt;There are System Sensor SGRLA remote strobes (red, wall-mount, small-footprint, bilingual lettering, set to 15cd) in all washrooms.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobe (red, wall-mount, set to 15cd) in the Unit 110 warehouse, likely new old stock.  &amp;lt;br&amp;gt;For outdoor notification, there is a System Sensor SRKA weatherproof remote strobe (red, wall-mount) outside the main mechanical room.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors at the top of each stairwell, in the server and janitor rooms of Unit 110, and in the main electrical room.  &amp;lt;br&amp;gt;There is a Notifier FST-851RA addressable 135°F fixed-temperature/rate-of-rise heat detector in the main mechanical room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a Notifier FSP-951A addressable photoelectric smoke detector in the server room of Unit 130, mounted on a System Sensor B300A-6 base.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;