<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=2050-2066_38_Ave_NW%2C_Edmonton</id>
	<title>2050-2066 38 Ave NW, Edmonton - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=2050-2066_38_Ave_NW%2C_Edmonton"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=2050-2066_38_Ave_NW,_Edmonton&amp;action=history"/>
	<updated>2026-06-09T23:59:45Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=2050-2066_38_Ave_NW,_Edmonton&amp;diff=12224&amp;oldid=prev</id>
		<title>TwentyThree33: FAA-300</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=2050-2066_38_Ave_NW,_Edmonton&amp;diff=12224&amp;oldid=prev"/>
		<updated>2025-02-09T17:35:58Z</updated>

		<summary type="html">&lt;p&gt;FAA-300&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-300 &amp;lt;br /&amp;gt;FACP Location: Sprinkler Control Room &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis &amp;lt;br /&amp;gt;Date of last known Upgrade: Early 2020s &amp;lt;br /&amp;gt;Year Opened: 2007&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;2050-2066 38 Ave NW&amp;#039;&amp;#039;&amp;#039; is the address given to a small commercial plaza in the RioCan Meadows shopping centre in Edmonton, AB. The plaza consists of PetSmart, Winners and SEPHORA. The building was completed in 2007, and the fire alarm system is mostly original with a panel replacement occurring in the early 2020s.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2007-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Mircom FA-300 conventional fire alarm system. The panel is located in the sprinkler control room. The system coding is temporal. &amp;lt;br&amp;gt; The FA-300 replaced the original EST QuickStart QSC in the early 2020s.&lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There are two Mircom RAM-300LCDR annunciators. One is outside the Winners entrance, and the other is in the entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Edwards “Genesis” G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations. &lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;