<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=4415_Manhattan_Road_SE%2C_Calgary</id>
	<title>4415 Manhattan Road SE, Calgary - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=4415_Manhattan_Road_SE%2C_Calgary"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=4415_Manhattan_Road_SE,_Calgary&amp;action=history"/>
	<updated>2026-04-27T16:44:05Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=4415_Manhattan_Road_SE,_Calgary&amp;diff=12387&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &lt;br /&gt;FACP Location: Bay 1, Main Sprinkler Room &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: 2025 &lt;br /&gt;Year Opened: 1967 |}  &#039;&#039;&#039;4415 Manhattan Road SE&#039;&#039;&#039; is the address of a small industrial strip mal...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=4415_Manhattan_Road_SE,_Calgary&amp;diff=12387&amp;oldid=prev"/>
		<updated>2025-03-15T01:45:31Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Bay 1, Main Sprinkler Room &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2025 &amp;lt;br /&amp;gt;Year Opened: 1967 |}  &amp;#039;&amp;#039;&amp;#039;4415 Manhattan Road SE&amp;#039;&amp;#039;&amp;#039; is the address of a small industrial strip mal...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Bay 1, Main Sprinkler Room &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2025 &amp;lt;br /&amp;gt;Year Opened: 1967&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;4415 Manhattan Road SE&amp;#039;&amp;#039;&amp;#039; is the address of a small industrial strip mall in Calgary, Alberta, Canada.  The building was built in 1967, and was extensively renovated in 2024/2025.  The fire alarm system was upgraded in 2025.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2025-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the main sprinkler room of Bay 1.  The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;Some areas have System Sensor PC2RLED-B horn/strobes (red, ceiling-mount, set to 15cd).  &amp;lt;br&amp;gt;For outdoor notification, there is a System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RKA weatherproof horn/strobe (red, wall-mount) outside Bay 1.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None present; the building has total sprinkler coverage.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>