<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=5005_50_St%2C_Beaumont</id>
	<title>5005 50 St, Beaumont - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=5005_50_St%2C_Beaumont"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=5005_50_St,_Beaumont&amp;action=history"/>
	<updated>2026-04-07T07:30:18Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=5005_50_St,_Beaumont&amp;diff=10212&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &lt;br /&gt;FACP Location: Main Entrance &lt;br /&gt;System Type: Single-Stage Add...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=5005_50_St,_Beaumont&amp;diff=10212&amp;oldid=prev"/>
		<updated>2024-09-03T03:56:04Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Main Entrance &amp;lt;br /&amp;gt;System Type: Single-Stage Add...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Main Entrance &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2022&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;5005 50 Street&amp;#039;&amp;#039;&amp;#039; is the address of a mixed-use building in Beaumont, AB. The building houses commercial retailers on the first floor, and condos on the second floor. The commercial portion of the building consists of Muse Beauty Haus, Macao Imperial Tea and Red Swan Pizza. The building was built in 2022, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2022-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance. The system runs Mircom’s Advanced addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All apartment hallways and lobby notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd). &amp;lt;br&amp;gt; Each lower floor tenant and condo unit has a Mircom FHS-400-WW horn/strobe (white, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors, mounted on System Sensor B210LPA bases. &lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. &amp;lt;br&amp;gt; There are System Sensor M500XA isolator modules on the SLCs.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MP-300 end-of-line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Commercial]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Beaumont]]&lt;/div&gt;</summary>