<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=5406_Discovery_Way%2C_Leduc</id>
	<title>5406 Discovery Way, Leduc - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=5406_Discovery_Way%2C_Leduc"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=5406_Discovery_Way,_Leduc&amp;action=history"/>
	<updated>2026-04-07T07:29:39Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=5406_Discovery_Way,_Leduc&amp;diff=10204&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addres...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=5406_Discovery_Way,_Leduc&amp;diff=10204&amp;oldid=prev"/>
		<updated>2024-09-03T03:51:56Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addres...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2012, 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;5406 Discovery Way&amp;#039;&amp;#039;&amp;#039; is the address of a mid-sized shopping plaza in Leduc, Alberta, Canada.  The plaza consists of Winners, Sport Chek, Great Clips, Michaels, Plantlife and Township Road Dental Centre.  The plaza was originally built in 2012, with Winners and Sport Chek as the original tenants, then was expanded in 2014 to add all other tenants.  The fire alarm system is original to both the expansion and original building.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel location is unknown.  The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are Notifier LCD2-80 annunciators paired with Notifier ACM-24AT annunciators outside Plantlife and in the Michaels entrance vestibule.  &amp;lt;br&amp;gt;There is a Notifier ACM-24AT annunciator installed remotely in the Winners entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All areas except Township Road Dental have System Sensor “SpectrAlert Advance” PC2WA horn/strobes (white, ceiling-mount, set to 15cd).  &amp;lt;br&amp;gt;Township Road Dental Centre has System Sensor P2RA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;For outdoor notification, there is a System Sensor SRKA weatherproof remote strobe (red, wall-mount) outside above the Plantlife annunciator.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Winners and Sport Chek have Notifier MPS-950B conventional single-action pull stations wired to Notifier FMM-101A addressable monitor modules.  &amp;lt;br&amp;gt;All other tenants have Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Leduc]]&lt;br /&gt;
[[Category:Strip Malls]]&lt;/div&gt;</summary>