<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Acura_Centre_of_Saskatoon</id>
	<title>Acura Centre of Saskatoon - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Acura_Centre_of_Saskatoon"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Acura_Centre_of_Saskatoon&amp;action=history"/>
	<updated>2026-04-07T07:31:04Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Acura_Centre_of_Saskatoon&amp;diff=12595&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, EST Self-Sync &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 2014 |}  &#039;&#039;&#039;Acura Centre of Saskatoon&#039;&#039;&#039; is an Acura car dealership located at 819 Melville Street, in...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Acura_Centre_of_Saskatoon&amp;diff=12595&amp;oldid=prev"/>
		<updated>2025-04-21T04:58:19Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS1 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST Self-Sync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Acura Centre of Saskatoon&amp;#039;&amp;#039;&amp;#039; is an Acura car dealership located at 819 Melville Street, in...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS1 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST Self-Sync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Acura Centre of Saskatoon&amp;#039;&amp;#039;&amp;#039; is an Acura car dealership located at 819 Melville Street, in Saskatoon, Saskatchewan, Canada.  The dealership was built in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST QuickStart QS1 addressable fire alarm system.  The panel location is unknown.  The system runs EST&amp;#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is an Edwards EST-SRA4 annunciator at the main entrance.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors at the top of each stairwell, mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-IM addressable isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Saskatchewan]]&lt;br /&gt;
[[Category:Dealerships]]&lt;/div&gt;</summary>