<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Birch_Hills_Landing_Phase_4</id>
	<title>Birch Hills Landing Phase 4 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Birch_Hills_Landing_Phase_4"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Birch_Hills_Landing_Phase_4&amp;action=history"/>
	<updated>2026-05-18T17:03:21Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Birch_Hills_Landing_Phase_4&amp;diff=13570&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&lt;br /&gt;FACP Location: Entrance Hallway&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2014 |}  &#039;&#039;&#039;Birch Hills Landing&#039;&#039;&#039; is an apartment complex owned and operated b...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Birch_Hills_Landing_Phase_4&amp;diff=13570&amp;oldid=prev"/>
		<updated>2026-03-06T21:25:36Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Entrance Hallway&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014 |}  &amp;#039;&amp;#039;&amp;#039;Birch Hills Landing&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and operated b...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Entrance Hallway&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2014&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Birch Hills Landing&amp;#039;&amp;#039;&amp;#039; is an apartment complex owned and operated by Broadstreet.  This page will cover Phase 4, located at 8501 Southfort Blvd, in Fort Saskatchewan, Alberta, Canada.  The building was built in 2014, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the entrance hallway.  The system runs Mircom&amp;#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).  &amp;lt;br&amp;gt;All suite bedrooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout most areas.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HA addressable 190°F fixed-temperature heat detectors in the mechanical room.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There is a System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housing equipped with a Mircom MIX-2251APA addressable photoelectric head on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Fort Saskatchewan]]&lt;br /&gt;
[[Category:Broadstreet]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;