<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Brewster_Mountain_Lodge</id>
	<title>Brewster Mountain Lodge - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Brewster_Mountain_Lodge"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Brewster_Mountain_Lodge&amp;action=history"/>
	<updated>2026-04-07T09:17:57Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Brewster_Mountain_Lodge&amp;diff=12667&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030C &lt;br /&gt;FACP Location: Main Entrance &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: 2018 &lt;br /&gt;Most Recent Known Modification: N/A &lt;br /&gt; Year Opened: 1996 |}  &#039;&#039;&#039;Brewster Mountain Lodge&#039;&#039;&#039; is 77-room ho...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Brewster_Mountain_Lodge&amp;diff=12667&amp;oldid=prev"/>
		<updated>2025-05-05T04:35:47Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030C &amp;lt;br /&amp;gt;FACP Location: Main Entrance &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2018 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1996 |}  &amp;#039;&amp;#039;&amp;#039;Brewster Mountain Lodge&amp;#039;&amp;#039;&amp;#039; is 77-room ho...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS2-3030C &amp;lt;br /&amp;gt;FACP Location: Main Entrance &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2018 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1996&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Brewster Mountain Lodge&amp;#039;&amp;#039;&amp;#039; is 77-room hotel located at 208 Caribou St, Banff, Alberta. The hotel opened in 1996, and the fire alarm system was upgraded in 2018.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2018-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel is located at the main entrance. The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
===== Booster Panels =====&lt;br /&gt;
&lt;br /&gt;
There are likely multiple Notifier ACPS-610 6/10-amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All common area notification appliances are System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, set to 15cd). &amp;lt;br&amp;gt; Each guest room has a System Sensor P2WLA horn/strobe (white, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are System Sensor FSP-951A addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300A-6 bases.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches. &amp;lt;br&amp;gt; There are Notifier FRM-1A addressable relay modules serving various purposes. &amp;lt;br&amp;gt; There are Notifier ISO-XA isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (1996-2018) ==&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST 6632  &amp;lt;br /&amp;gt;FACP Location: Main Entrance &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt; Most Recent Known Modification: 2010s (Smoke Detectors) &amp;lt;br/&amp;gt; Year Installed: 1996 &amp;lt;br /&amp;gt;Year Decommissioned: 2018&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building was protected by an EST 6632 conventional fire alarm system. The panel was located at the main entrance. The system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All common area notification appliances were Edwards &amp;quot;Integrity&amp;quot; 757-5A-HS horn/strobes (red, wall-mount, 15cd). &amp;lt;br&amp;gt; Each guest room had an Edwards 692-5A-003 mini-horn/strobe (white, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations were Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There were System Sensor C2W-BA conventional photoelectric smoke detectors throughout the building. &lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There were Edwards EOL-P1 end-of-line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Hotels]]&lt;br /&gt;
[[Category:Banff]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>