<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=CNRL_Pike_Lodge</id>
	<title>CNRL Pike Lodge - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=CNRL_Pike_Lodge"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=CNRL_Pike_Lodge&amp;action=history"/>
	<updated>2026-05-18T21:00:08Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=CNRL_Pike_Lodge&amp;diff=13617&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030C&lt;br /&gt;FACP Location: Various&lt;br /&gt;System Type: Single-Stage Networked Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, System Sensor&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2015 |}  &#039;&#039;&#039;Canadian Natural Resources Ltd&#039;&#039;&#039; is an oil an...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=CNRL_Pike_Lodge&amp;diff=13617&amp;oldid=prev"/>
		<updated>2026-03-06T21:38:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030C&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Single-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2015 |}  &amp;#039;&amp;#039;&amp;#039;Canadian Natural Resources Ltd&amp;#039;&amp;#039;&amp;#039; is an oil an...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS2-3030C&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Single-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Canadian Natural Resources Ltd&amp;#039;&amp;#039;&amp;#039; is an oil and gas production company. This page will cover the &amp;#039;&amp;#039;&amp;#039;Pike Lodge&amp;#039;&amp;#039;&amp;#039;, a workers&amp;#039; camp located near Conklin, Alberta, Canada. The camp was built in 2015, and the fire alarm systems are original. &amp;lt;br&amp;gt; Please note that the system is a Notifier NOTI-FIRE-NET network, and was constructed all as one building. &lt;br /&gt;
&lt;br /&gt;
==System Specifications (Main Lodge)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier NFS2-3030C addressable fire alarm system.  The panel is located in the utility room.  The system runs Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Notifier NCA-2C annunciator paired with a custom graphic in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are Notifier ACPS-610 power supplies throughout.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;Some areas have System Sensor PC2WA horn/strobes (white, ceiling-mount, set to 15cd).  &amp;lt;br&amp;gt;The washrooms have System Sensor SRA remote strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;For outdoor notification, there is a System Sensor SRKA weatherproof remote strobe (red, wall-mount) outside.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSP-851A addressable photoelectric smoke detectors in most areas.  &amp;lt;br&amp;gt;There are Notifier FST-851A addressable 135°F fixed-temperature heat detectors in areas such as janitor rooms.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on System Sensor B210LPA bases.  &amp;lt;br&amp;gt;There are System Sensor &amp;quot;Innovair Flex&amp;quot; DNRA duct smoke detector housings equipped with Notifier FSP-851A addressable photoelectric heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FDM-1A addressable dual-input monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier FRM-1A addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on all SLCs.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (Dorms)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The dorms are protected by Notifier NFS2-3030C addressable fire alarm systems.  The panels are located in the utility room of each building.  The systems run Notifier&amp;#039;s FlashScan addressable protocol, and the system coding is temporal for all systems.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators======&lt;br /&gt;
There are Notifier LCD2-80 annunciators paired with Notifier ACM-24AT annunciators at the entrance to each dorm.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert Advance&amp;quot; PC2WA horn/strobes (white, ceiling-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSI-851A addressable ionization smoke detectors throughout all common areas.  &amp;lt;br&amp;gt;There are Notifier FSP-851A addressable photoelectric smoke detectors in each dorm room.  &amp;lt;br&amp;gt;All common area detectors are mounted on System Sensor B210LPA bases, while all dorm room detectors are mounted on System Sensor B200SRA sounder bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Notifier FDM-1A addressable dual-input monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Notifier FRM-1A addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are Notifier ISO-XA isolator modules on all SLCs.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are a mix of Notifier EOL-CR, Edwards EOL-P1 and Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>