		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards Custom 6500 &lt;br /&gt;FACP Location: Unknown  &lt;br /&gt;System Type: Single-Stage Conventional &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Continuous &lt;br /&gt;Date of last known Upgrade: 1981 &lt;br /&gt;Year Opened: 1900 |}  The &#039;&#039;&#039;Cabot Tower&#039;&#039;&#039; is a tower and historic landmark located on Signal Hill Road, St. Johns, Newfoundland and Labrador. It began co...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Cabot_Tower&amp;diff=11499&amp;oldid=prev"/>
		<updated>2024-10-23T20:06:16Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards Custom 6500 &amp;lt;br /&amp;gt;FACP Location: Unknown  &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br /&amp;gt;Date of last known Upgrade: 1981 &amp;lt;br /&amp;gt;Year Opened: 1900 |}  The &amp;#039;&amp;#039;&amp;#039;Cabot Tower&amp;#039;&amp;#039;&amp;#039; is a tower and historic landmark located on Signal Hill Road, St. Johns, Newfoundland and Labrador. It began co...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards Custom 6500 &amp;lt;br /&amp;gt;FACP Location: Unknown  &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br /&amp;gt;Date of last known Upgrade: 1981 &amp;lt;br /&amp;gt;Year Opened: 1900&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &amp;#039;&amp;#039;&amp;#039;Cabot Tower&amp;#039;&amp;#039;&amp;#039; is a tower and historic landmark located on Signal Hill Road, St. Johns, Newfoundland and Labrador. It began construction in 1898 for the 400th anniversary of John Cabot’s arrival, and was finished in 1900. The fire alarm system was installed in 1981.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (1981-present) ==&lt;br /&gt;
NOTE: This page is accurate to August 21, 2019.&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by an Edwards Custom 6500 conventional fire alarm system. The panel location is unknown. The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances but one are Edwards “Adaptabel” 343D vibrating bells (6” gong). &amp;lt;br&amp;gt; There is a Mircom BL-6B motor bell (6” gong) as a deficiency replacement.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Edwards 6249C conventional ionization smoke detectors. &amp;lt;br&amp;gt; There is one System Sensor 1400A conventional ionization smoke detector. &amp;lt;br&amp;gt; There are System Sensor “i3” C2W-BA conventional photoelectric smoke detectors as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.&lt;br /&gt;