<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Canadian_Bio_Systems</id>
	<title>Canadian Bio Systems - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Canadian_Bio_Systems"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Canadian_Bio_Systems&amp;action=history"/>
	<updated>2026-09-04T17:47:37Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Canadian_Bio_Systems&amp;diff=13861&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier SFP-10UDC&lt;br /&gt;FACP Location: Main Entrance&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2004 |}  &#039;&#039;&#039;Canadian Bio Systems&#039;&#039;&#039; is a livestock product company located at...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Canadian_Bio_Systems&amp;diff=13861&amp;oldid=prev"/>
		<updated>2026-09-03T23:35:49Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier SFP-10UDC&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2004 |}  &amp;#039;&amp;#039;&amp;#039;Canadian Bio Systems&amp;#039;&amp;#039;&amp;#039; is a livestock product company located at...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier SFP-10UDC&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2004&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Canadian Bio Systems&amp;#039;&amp;#039;&amp;#039; is a livestock product company located at 7072 112 Ave SE, in Calgary, Alberta, Canada.  The building was built in 2004, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier SFP-10UDC conventional fire alarm system.  The panel is located at the main entrance.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P1224MCA horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;Some areas have System Sensor &amp;quot;L-Series&amp;quot; P2RLA horn/strobes (red, wall-mount, set to 15cd) as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors at the top of each stairwell.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;br /&gt;
[[Category:Notifier]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
</feed>