<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Centre_Pointe_West</id>
	<title>Centre Pointe West - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Centre_Pointe_West"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Centre_Pointe_West&amp;action=history"/>
	<updated>2026-04-27T22:22:04Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Centre_Pointe_West&amp;diff=10152&amp;oldid=prev</id>
		<title>TwentyThree33: British people pronounce words incorrectly.</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Centre_Pointe_West&amp;diff=10152&amp;oldid=prev"/>
		<updated>2024-08-20T23:01:15Z</updated>

		<summary type="html">&lt;p&gt;British people pronounce words incorrectly.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Hybrid-Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: 2017 &amp;lt;br /&amp;gt;Year Opened: 1981&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Centre Pointe West&amp;#039;&amp;#039;&amp;#039; is an apartment building located at 1313 13 Ave SW, Calgary, Alberta. The building was built in 1981, and the fire alarm system was upgraded in 2017.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2017-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Mircom FX-2000 hybrid-addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
Most notification appliances are System Sensor “SpectrAlert Advance” P2RA horn/strobes (red, wall-mount, set to 15cd). &amp;lt;br&amp;gt; There are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, set to 15cd) as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
Most pull stations but one are Notifier N-MPS-SC conventional single-action pull stations. &amp;lt;br&amp;gt; There is a Mircom MS-401 conventional single-action pull station in the main floor back exit corridor. &lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are System Sensor “i3” C2W-BA conventional photoelectric smoke detectors in all corridors, as well as some other rooms. &amp;lt;br&amp;gt; The elevator lobbies, machine room and elevator shaft have Mircom MIX-2251APA addressable photoelectric smoke detectors, mounted on System Sensor B210LPA bases. &amp;lt;br&amp;gt; The garbage rooms have Mirtone 73330 conventional 135°F fixed-temperature heat detectors. &amp;lt;br&amp;gt; There is a System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detector in the 2nd floor garbage room as a deficiency replacement. &amp;lt;br&amp;gt; There is a Potter CR-135W conventional 135°F fixed-temperature/rate-of-rise heat detector in the elevator machine room. &lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MIX-M500RA addressable relay modules for MUA shutdown and elevator recall. &amp;lt;br&amp;gt; There are two System Sensor M500XA isolator modules per floor, located in the garbage rooms.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MP-300 end-of-line resistor plates on all circuits. &lt;br /&gt;