		<id>https://firealarmpedia.org/index.php?title=Comfort_Inn_Winnipeg_South&amp;diff=11718&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Siemens TXL-1000 &lt;br /&gt;FACP Location: Behind Front Desk &lt;br /&gt;System Type: Single-Stage Conventional &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal? &lt;br&gt;Strobes Synchronized: N/A &lt;br /&gt;Date of last known Upgrade: 2000s &lt;br /&gt;Year Opened: 1986 |}  &#039;&#039;&#039;Comfort Inn&#039;&#039;&#039; is a chain of mid-level hotels owned by Choice Hotels.  The chain is headquart...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Comfort_Inn_Winnipeg_South&amp;diff=11718&amp;oldid=prev"/>
		<updated>2024-11-29T19:37:21Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens TXL-1000 &amp;lt;br /&amp;gt;FACP Location: Behind Front Desk &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal? &amp;lt;br&amp;gt;Strobes Synchronized: N/A &amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s &amp;lt;br /&amp;gt;Year Opened: 1986 |}  &amp;#039;&amp;#039;&amp;#039;Comfort Inn&amp;#039;&amp;#039;&amp;#039; is a chain of mid-level hotels owned by Choice Hotels.  The chain is headquart...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens TXL-1000 &amp;lt;br /&amp;gt;FACP Location: Behind Front Desk &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal? &amp;lt;br&amp;gt;Strobes Synchronized: N/A &amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s &amp;lt;br /&amp;gt;Year Opened: 1986&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Comfort Inn&amp;#039;&amp;#039;&amp;#039; is a chain of mid-level hotels owned by Choice Hotels.  The chain is headquartered in Rockville, Maryland, USA, and has locations worldwide.  This particular hotel is located at 3109 Pembina Highway, in Winnipeg, Manitoba, Canada.  The hotel was built in 1986, and the fire alarm system was partially upgraded in the 2000s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2000s-present)==&lt;br /&gt;
Please note that some system details are unconfirmed.  This page should not be used for official purposes.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Siemens TXL-1000 conventional fire alarm system.  The panel is located behind the front desk.  The system coding is likely temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are likely Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Siemens OP121 conventional photoelectric smoke detectors throughout all corridors.  &amp;lt;br&amp;gt;There are Mircom TD-135 conventional 135°F fixed-temperature heat detectors in all guest rooms.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in some common areas.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resost&lt;/div&gt;</summary>