<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Costco_Wholesale_%28Bend%29</id>
	<title>Costco Wholesale (Bend) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Costco_Wholesale_%28Bend%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Costco_Wholesale_(Bend)&amp;action=history"/>
	<updated>2026-04-07T09:17:53Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Costco_Wholesale_(Bend)&amp;diff=12454&amp;oldid=prev</id>
		<title>Somedudewithanexitsign: Beware of Hunter</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Costco_Wholesale_(Bend)&amp;diff=12454&amp;oldid=prev"/>
		<updated>2025-03-24T19:39:43Z</updated>

		<summary type="html">&lt;p&gt;Beware of Hunter&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Potter AFC-1000 &amp;lt;br /&amp;gt;&lt;br /&gt;
FACP Location: Main Exit &amp;lt;br /&amp;gt;&lt;br /&gt;
System Type: Addressable &amp;lt;br /&amp;gt; &lt;br /&gt;
System Line Voltage: 120VAC&amp;lt;br /&amp;gt;&lt;br /&gt;
NAC Voltage: 24VDC &amp;lt;br /&amp;gt;&lt;br /&gt;
System Coding: Temporal 3 &amp;lt;br /&amp;gt;&lt;br /&gt;
Strobes Synchronized Yes &amp;lt;br&amp;gt;&lt;br /&gt;
Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;&lt;br /&gt;
Year Opened: 2024&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Costco Wholesale&amp;#039;&amp;#039;&amp;#039; is a a members only sales club. This location is located at 62207 NW Costco Dr, Bend, OR. This location replaced a older location located at 2500 NE Hwy 26, Bend, OR&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
===FACP===&lt;br /&gt;
The building is protected by a Potter AFC-1000 fire alarm system.  The panel is located at the Main Exit.  The system runs Potter&amp;#039;s PAD addressable protocol, and the system coding is Temporal 3.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most Notification Appliances are System Sensor &amp;quot;L-Series with LED&amp;quot; PC2WLED Horn Strobes (White, Ceiling-Mount, Various Cd) with a mixture of System Sensor &amp;quot;L-Series with LED&amp;#039; SCWLED Strobes (White, Ceiling-mount, Various Cd). The Dairy, Fresh Produce, Kirkland Bakery, Krikland Meat, Kirkland Retostary, Kirkland Bakery and Food Court Kitchen have a mixture of System Sensor &amp;quot;SpectrAlert Advance&amp;quot; PC2WK Horn Strobes (White, Ceiling-mount, Various cd) and System Sensor &amp;quot;SpectrAlert Advance&amp;quot; SCWK Strobes (White, Ceiling-Mount, Various Cd). Some areas have a mixture of System Sensor &amp;quot;L-Series with LED&amp;quot; P2WLED Horn Strobes (White, Wall-mount, Set on 75cd) and System Sensor &amp;quot;L-Series with LED&amp;quot; SWLED Strobes (White, Wall-mount, Set on 15cd and 75cd). The outdoor device is a System Sensor &amp;quot;SpectrAlert Advance&amp;quot; P2RK Horn Strobe (Red, Wall-mount, set on 110cd)&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The only Pull Station on the system is a Potter PAD100-PSDA Dual Action Addressable Pull Station&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
&lt;br /&gt;
The only Smoke Detector on the system is a Potter PAD200-PD Addressable Photoelectric Smoke Detector.&lt;/div&gt;</summary>