	<entry>
		<id>https://firealarmpedia.org/index.php?title=Courtyard_Louisville_Downtown&amp;diff=11716&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Cerberus Pyrotronics MXL &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 1999 |}  &#039;&#039;&#039;Courtyard&#039;&#039;&#039; is a chain of mid-range hotels owned by Marriott.  The chain is headquartered in Bethesda, Maryland, U...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Courtyard_Louisville_Downtown&amp;diff=11716&amp;oldid=prev"/>
		<updated>2024-11-29T19:35:53Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Cerberus Pyrotronics MXL &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 1999 |}  &amp;#039;&amp;#039;&amp;#039;Courtyard&amp;#039;&amp;#039;&amp;#039; is a chain of mid-range hotels owned by Marriott.  The chain is headquartered in Bethesda, Maryland, U...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Cerberus Pyrotronics MXL &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 1999&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Courtyard&amp;#039;&amp;#039;&amp;#039; is a chain of mid-range hotels owned by Marriott.  The chain is headquartered in Bethesda, Maryland, USA, and has locations worldwide.  This particular hotel is located at 100 South 2nd Street, in Louisville, Kentucky, USA.  The hotel was built in 1999, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Cerberus Pyrotronics MXL addressable fire alarm system.  The panel location is unknown.  The system runs Cerberus Pyrotronics’ FirePrint addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most common area notification appliances are Cerberus Pyrotronics U-MMT-S17 horn/strobes (red, wall-mount, 15cd, set to horn).  &amp;lt;br&amp;gt;Some common areas have Cerberus Pyrotronics U-S17 remote strobes (red, wall-mount, 15cd).  &amp;lt;br&amp;gt;All guest rooms have Cerberus Pyrotronics U-MHU-1G-W remote horns (white, wall-mount).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Cerberus Pyrotronics MSI-10B addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Cerberus Pyrotronics FP-11 addressable multisensor smoke/heat detectors throughout all common areas, mounted on Cerberus Pyrotronics DB-11 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Cerberus Pyrotronics TRI-D addressable monitor modules supervising the sprinkler system’s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
[[Category:Kentucky]]&lt;br /&gt;