<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Doubletree_by_Hilton_Milwaukee_Downtown</id>
	<title>Doubletree by Hilton Milwaukee Downtown - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Doubletree_by_Hilton_Milwaukee_Downtown"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Doubletree_by_Hilton_Milwaukee_Downtown&amp;action=history"/>
	<updated>2026-04-27T18:07:57Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Doubletree_by_Hilton_Milwaukee_Downtown&amp;diff=12087&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70.7VRMS (Audible) &lt;br&gt;24VDC (Visual) &lt;br /&gt;System Coding: Unknown &lt;br&gt;Strobes Synchronized: Yes, per-NAC &lt;br /&gt;Date of last known Upgrade: 2017 &lt;br /&gt;Year Opened: 1967 |}  &#039;&#039;&#039;DoubleTree by Hilton&#039;&#039;&#039; is an upscale hotel chain owned by Hilton.  They are headqua...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Doubletree_by_Hilton_Milwaukee_Downtown&amp;diff=12087&amp;oldid=prev"/>
		<updated>2025-01-19T22:08:46Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible) &amp;lt;br&amp;gt;24VDC (Visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, per-NAC &amp;lt;br /&amp;gt;Date of last known Upgrade: 2017 &amp;lt;br /&amp;gt;Year Opened: 1967 |}  &amp;#039;&amp;#039;&amp;#039;DoubleTree by Hilton&amp;#039;&amp;#039;&amp;#039; is an upscale hotel chain owned by Hilton.  They are headqua...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible) &amp;lt;br&amp;gt;24VDC (Visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, per-NAC &amp;lt;br /&amp;gt;Date of last known Upgrade: 2017 &amp;lt;br /&amp;gt;Year Opened: 1967&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;DoubleTree by Hilton&amp;#039;&amp;#039;&amp;#039; is an upscale hotel chain owned by Hilton.  They are headquartered in McLean, Virginia, and are known for their complimentary warm chocolate chip cookies, which are said to be delicious.  This particular hotel is located at 611 W Wisconsin Ave, in Downtown Milwaukee, Wisconsin, USA.  The hotel was built in 1967, and was renovated in 2017.  The fire alarm system is believed to be from 2017.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system.  The panel location is unknown, however the model has been confirmed based on the size of the building and the initiating devices.  The system runs EST’s Signature-series addressable protocol, and is equipped with voice evacuation, however the messages and/or tones are unknown.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards “Integrity” 757-5A-SS70 speaker/strobes (red, wall-mount, 70V, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;