<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=ELYMI_Family_Buffet</id>
	<title>ELYMI Family Buffet - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=ELYMI_Family_Buffet"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ELYMI_Family_Buffet&amp;action=history"/>
	<updated>2026-04-28T01:59:14Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=ELYMI_Family_Buffet&amp;diff=12623&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mirtone MIR1-2Z6 &lt;br /&gt;FACP Location: Main Entrance Vestibule &lt;br /&gt;System Type: Single-Stage Conventional &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, Mirtone Self-Sync &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 1999 |}  &#039;&#039;&#039;ELYMI Family Buffet&#039;&#039;&#039; is an all-you-can-eat buffet restaurant located a...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=ELYMI_Family_Buffet&amp;diff=12623&amp;oldid=prev"/>
		<updated>2025-04-29T03:03:03Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mirtone MIR1-2Z6 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mirtone Self-Sync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 1999 |}  &amp;#039;&amp;#039;&amp;#039;ELYMI Family Buffet&amp;#039;&amp;#039;&amp;#039; is an all-you-can-eat buffet restaurant located a...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mirtone MIR1-2Z6 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mirtone Self-Sync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 1999&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;ELYMI Family Buffet&amp;#039;&amp;#039;&amp;#039; is an all-you-can-eat buffet restaurant located at 3030 23 St NE, in Calgary, Alberta, Canada.  The building was built in 1999 as Tony Roma&amp;#039;s, and was converted into ELYMI in 2024.  The fire alarm system is mostly original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mirtone MIR1-2Z6 conventional fire alarm system.  The panel is located in the main entrance vestibule.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mirtone &amp;quot;Integrity&amp;quot; INT-5AT horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401 conventional single-action pull stations.  &amp;lt;br&amp;gt;These replaced Mirtone 73353 conventional single-action pull stations in the 2010s.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors throughout most areas.  &amp;lt;br&amp;gt;There are two System Sensor 5604A conventional 194°F fixed-temperature heat detectors in the kitchen.  &amp;lt;br&amp;gt;There is a System Sensor C2W-BA conventional photoelectric smoke detector in the main entrance vestibule.  &amp;lt;br&amp;gt;The restaurant&amp;#039;s kitchen suppression system is tied into the fire alarm system.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;