<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Edmonton_South_Soccer_Centre</id>
	<title>Edmonton South Soccer Centre - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Edmonton_South_Soccer_Centre"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Edmonton_South_Soccer_Centre&amp;action=history"/>
	<updated>2026-04-07T10:41:54Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Edmonton_South_Soccer_Centre&amp;diff=12142&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, Mircom &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 2004, 2022 |}  The &#039;&#039;&#039;Edmonton South Soccer Centre&#039;&#039;&#039; is an indoor soccer field house located at 6520 Roper Road...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Edmonton_South_Soccer_Centre&amp;diff=12142&amp;oldid=prev"/>
		<updated>2025-01-27T05:28:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2004, 2022 |}  The &amp;#039;&amp;#039;&amp;#039;Edmonton South Soccer Centre&amp;#039;&amp;#039;&amp;#039; is an indoor soccer field house located at 6520 Roper Road...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2004, 2022&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The &amp;#039;&amp;#039;&amp;#039;Edmonton South Soccer Centre&amp;#039;&amp;#039;&amp;#039; is an indoor soccer field house located at 6520 Roper Road NW, in Edmonton, Alberta, Canada.  The building was built in 2004, and was expanded in 2022.  The fire alarm system is original to both portions.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel location is unknown.  The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The original portion has Mircom “Select-A-Horn/Strobe” FHS-240R horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;The expansion has Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
The original portion has Mircom MS-401AD addressable single-action pull stations.  &amp;lt;br&amp;gt;The expansion has Mircom MS-401AP addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251APA addressable photoelectric smoke detectors in some areas, mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt;There are Mircom MIX-M500RA addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are System Sensor M500XA isolator modules on the SLC.  &amp;lt;br&amp;gt;There are Mircom SDM-240 sync modules synchronizing all horn/strobes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;