<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Embassy_Suites_by_Hilton_Fort_Lauderdale</id>
	<title>Embassy Suites by Hilton Fort Lauderdale - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Embassy_Suites_by_Hilton_Fort_Lauderdale"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Embassy_Suites_by_Hilton_Fort_Lauderdale&amp;action=history"/>
	<updated>2026-04-27T23:52:08Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Embassy_Suites_by_Hilton_Fort_Lauderdale&amp;diff=10219&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Addressable &lt;br /&gt;System...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Embassy_Suites_by_Hilton_Fort_Lauderdale&amp;diff=10219&amp;oldid=prev"/>
		<updated>2024-09-03T03:58:40Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible) &amp;lt;br&amp;gt;24VDC (Visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis &amp;lt;br /&amp;gt;Date of last known Upgrade: 2007 &amp;lt;br /&amp;gt;Year Opened: 1987&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Embassy Suites&amp;#039;&amp;#039;&amp;#039; is a chain of midrange hotels owned by Hilton.  The chain is known for their large atriums.  This particular hotel is located at 1100 SE 17th Street, in Fort Lauderdale, Florida, USA.  The hotel was built in 1987, and was renovated in 2007.  The fire alarm system was upgraded as part of the 2007 renovation.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2007-present)==&lt;br /&gt;
Please note that these system details are unconfirmed as little information was available, and some details are likely not accurate.  This page should not be used for official purposes.  Fire Alarmpedia is not responsible for any issues caused by inaccuracies.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system.  The panel location is unknown.  The system runs Edwards’ Signature addressable protocol, and is equipped with voice evacuation.  The messages and/or tones are unknown at this time.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All audible notification appliances are Edwards 965-1A-4RW remote speakers (white, ceiling-mount, 70V, 4” round).  &amp;lt;br&amp;gt;All visual notification appliances are Edwards “Genesis” G1-VM remote strobes (white, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors throughout all common areas, mounted on EST SIGA-SB4 bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
[[Category:Florida]]&lt;br /&gt;