	<entry>
		<id>https://firealarmpedia.org/index.php?title=FedEx_Calgary_Supply_Chain&amp;diff=13842&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&lt;br /&gt;FACP Location: Main Electrical Room&lt;br /&gt;System Type: Two-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: 20BPM (Alert)&lt;br&gt;Temporal (Alarm)&lt;br&gt;Strobes Synchronized: Yes, Self-Sync&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2001 |}  &#039;&#039;&#039;FedEx Calgary Supply Chain&#039;&#039;&#039; is...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=FedEx_Calgary_Supply_Chain&amp;diff=13842&amp;oldid=prev"/>
		<updated>2026-09-03T23:29:52Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2001 |}  &amp;#039;&amp;#039;&amp;#039;FedEx Calgary Supply Chain&amp;#039;&amp;#039;&amp;#039; is...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Main Electrical Room&amp;lt;br /&amp;gt;System Type: Two-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: 20BPM (Alert)&amp;lt;br&amp;gt;Temporal (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2001&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;FedEx Calgary Supply Chain&amp;#039;&amp;#039;&amp;#039; is a Canadian Tire distribution centre located at 6336 114 Ave SE, in Calgary, Alberta, Canada.  The building was built in 2001, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system.  This is a networked system; the main node is located in the main electrical room.  The system runs Edwards&amp;#039; Signature addressable protocol, and is configured for two-stage operation.  The alert signal coding is 20BPM, and the alarm signal coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are Edwards EST3-LCDANN annunciators at the security desk and gatehouse.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There are over 20 Edwards BPS6AC 6 amp booster power supplies on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are General Signal MB10-24 motor bells (10&amp;quot; gong) mounted on Edwards 403-5A-R strobe plates (15cd).  &amp;lt;br&amp;gt;Areas with higher ambient noise levels have Edwards 5520D-AW horns paired with high-output red strobes.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA2-PS addressable photoelectric smoke detectors on all pick mods.  &amp;lt;br&amp;gt;There are EST SIGA-PS addressable photoelectric smoke detectors in some areas.  &amp;lt;br&amp;gt;There are EST SIGA-HRS addressable 135°F fixed-temperature/rate-of-rise heat detectors in all electrical rooms.  &amp;lt;br&amp;gt;All detectors are mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising various auxiliary functions, such as the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-IM addressable isolator modules on all SLCs.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits supervised by monitor modules, and on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Industrial]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>