<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Gillette_Stadium</id>
	<title>Gillette Stadium - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Gillette_Stadium"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Gillette_Stadium&amp;action=history"/>
	<updated>2026-04-28T03:15:32Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Gillette_Stadium&amp;diff=13328&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS&lt;br /&gt;FACP Location: Various&lt;br /&gt;System Type: Networked Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70.7VRMS (Audible)&lt;br&gt;24VDC (Visual)&lt;br /&gt;System Coding: Unknown&lt;br&gt;Strobes Synchronized: Yes, Siemens&lt;br /&gt;Date of last known Upgrade: 2010s&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2002 |}  &#039;&#039;&#039;Gillette Stadium&#039;&#039;&#039; is a footb...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Gillette_Stadium&amp;diff=13328&amp;oldid=prev"/>
		<updated>2025-09-05T01:33:02Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2002 |}  &amp;#039;&amp;#039;&amp;#039;Gillette Stadium&amp;#039;&amp;#039;&amp;#039; is a footb...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens FireFinder XLS&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: Unknown&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens&amp;lt;br /&amp;gt;Date of last known Upgrade: 2010s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2002&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Gillette Stadium&amp;#039;&amp;#039;&amp;#039; is a football stadium located at 1 Patriot Place, in Foxborough, Massachusetts, USA.  The stadium is home to the New England Patriots of the National Football League (NFL).  The stadium was built in 2002, and the fire alarm system was upgraded in the 2010s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2010s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Siemens FireFinder XLS addressable fire alarm system.  This is a networked system with many nodes, the locations of which are unknown.  The system runs Siemens&amp;#039; FirePrint addressable protocol, and is equipped with voice evacuation.  The evacuation signal is unknown.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Siemens SSD-C annunciator at one entrance.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All indoor notification appliances are Siemens SEF-MC-R speaker/strobes (red, wall-mount, set to 70V/15cd).  &amp;lt;br&amp;gt;The concourse area has Siemens S-15WR high-output speakers (red) paired with Siemens ST-HMC-R-WP weatherproof remote strobes (red).  &amp;lt;br&amp;gt;The stadium&amp;#039;s public address system is used for audible signaling in the seating bowl.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Siemens HMS-S addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Siemens HFP-11 addressable multisensor smoke/heat detectors in some areas, mounted on Siemens DB-11 bases.  &amp;lt;br&amp;gt;There are Siemens FDBZ492 duct smoke detector housings equipped with Siemens HFP-11 addressable multisensor heads on air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Siemens HTRI-D addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Siemens HTRI-S addressable monitor modules supervising all kitchen suppression systems.  &amp;lt;br&amp;gt;There are Siemens HTRI-R addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
[[Category:Massachussetts]]&lt;br /&gt;
[[Category:NFL Stadiums]]&lt;br /&gt;
[[Category:Siemens]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>