<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hilton_Motif_Seattle</id>
	<title>Hilton Motif Seattle - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hilton_Motif_Seattle"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hilton_Motif_Seattle&amp;action=history"/>
	<updated>2026-04-27T18:07:10Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Hilton_Motif_Seattle&amp;diff=12013&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: /* FACP */</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hilton_Motif_Seattle&amp;diff=12013&amp;oldid=prev"/>
		<updated>2025-01-12T19:46:25Z</updated>

		<summary type="html">&lt;p&gt;&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;FACP&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:46, 12 January 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l13&quot;&gt;Line 13:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==System Specifications==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==System Specifications==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====FACP====&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====FACP====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The hotel is protected by a Siemens FireFinder XLS addressable fire alarm system.  The panel location is unknown, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;however the model &lt;/del&gt;is &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;speculated based on the initiating devices&lt;/del&gt;. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;The system is &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;two stage and voice evac, however the messages and/or tones are &lt;/del&gt;unknown.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The hotel is protected by a Siemens FireFinder XLS addressable fire alarm system.  The panel location is unknown&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The system runs Siemens&#039; FirePrint addressable protocol&lt;/ins&gt;, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and &lt;/ins&gt;is &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;equipped with voice-evacuation&lt;/ins&gt;. The system &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;coding &lt;/ins&gt;is unknown.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====Notification Appliances====&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====Notification Appliances====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Hilton_Motif_Seattle&amp;diff=12012&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70VRMS (audible) &lt;br&gt; 24VDC (visual) &lt;br /&gt;System Coding: Unknown &lt;br&gt;Strobes Synchronized: Yes, Siemens &lt;br /&gt;Date of last known Upgrade: 2014 &lt;br /&gt;Year Opened: 1970 |}   &#039;&#039;&#039;Hilton&#039;&#039;&#039; is a chain of upscale hotels across the globe. This particular h...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hilton_Motif_Seattle&amp;diff=12012&amp;oldid=prev"/>
		<updated>2025-01-12T19:44:57Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens FireFinder XLS &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS (audible) &amp;lt;br&amp;gt; 24VDC (visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens &amp;lt;br /&amp;gt;Date of last known Upgrade: 2014 &amp;lt;br /&amp;gt;Year Opened: 1970 |}   &amp;#039;&amp;#039;&amp;#039;Hilton&amp;#039;&amp;#039;&amp;#039; is a chain of upscale hotels across the globe. This particular h...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens FireFinder XLS &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS (audible) &amp;lt;br&amp;gt; 24VDC (visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Siemens &amp;lt;br /&amp;gt;Date of last known Upgrade: 2014 &amp;lt;br /&amp;gt;Year Opened: 1970&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Hilton&amp;#039;&amp;#039;&amp;#039; is a chain of upscale hotels across the globe. This particular hotel is located at 1415 5 Ave, Seattle, Washington.  The hotel has 29 floors, 256 guest rooms, and 4 meeting rooms, as well as a business center and a fitness center.  The hotel opened its doors in 1970, and was last renovated in 2014.  The fire alarm system was installed following the 2014 renovation.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The hotel is protected by a Siemens FireFinder XLS addressable fire alarm system.  The panel location is unknown, however the model is speculated based on the initiating devices.  The system is two stage and voice evac, however the messages and/or tones are unknown.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common areas of the hotel have Siemens SET-MC-CW speaker/strobes (white, ceiling-mount).  The guest rooms have Siemens SEF-W remote speakers (white, wall-mount).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Siemens HMS-D addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
All areas of the hotel, including guest rooms, have Siemens “FirePrint” FP-11 multisensor smoke/heat detectors.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Siemens XTRI-M addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
[[Category:Hotels]]&lt;br /&gt;
[[Category:Washington]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>