<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Holiday_Inn_Express_Stellarton-New_Glasgow</id>
	<title>Holiday Inn Express Stellarton-New Glasgow - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Holiday_Inn_Express_Stellarton-New_Glasgow"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Holiday_Inn_Express_Stellarton-New_Glasgow&amp;action=history"/>
	<updated>2026-09-04T04:26:49Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Holiday_Inn_Express_Stellarton-New_Glasgow&amp;diff=13867&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS4&lt;br /&gt;FACP Location: Behind Front Desk&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Self-Sync&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2008 |}  &#039;&#039;&#039;Holiday Inn Express&#039;&#039;&#039; is a chain of hotels owned...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Holiday_Inn_Express_Stellarton-New_Glasgow&amp;diff=13867&amp;oldid=prev"/>
		<updated>2026-09-03T23:37:31Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS4&amp;lt;br /&amp;gt;FACP Location: Behind Front Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008 |}  &amp;#039;&amp;#039;&amp;#039;Holiday Inn Express&amp;#039;&amp;#039;&amp;#039; is a chain of hotels owned...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS4&amp;lt;br /&amp;gt;FACP Location: Behind Front Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2008&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Holiday Inn Express&amp;#039;&amp;#039;&amp;#039; is a chain of hotels owned by IHG.  This particular hotel is located at 86 Lawrence Blvd, in Stellarton, Nova Scotia, Canada.  The building was built in 2008, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST QuickStart QS4 addressable fire alarm system.  The panel is located behind the front desk.  The system runs EST&amp;#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common area notification appliances are Edwards &amp;quot;Genesis&amp;quot; GC-HDVM horn/strobes (white, ceiling-mount, no marking, set to 15cd).  &amp;lt;br&amp;gt;All guest rooms have Edwards GC-VM remote strobes (white, ceiling-mount, no marking, set to 15cd) and sounder bases.&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGC-270B addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-IPHS addressable multi-criteria smoke/heat detectors throughout all common areas and in all guest rooms.  &amp;lt;br&amp;gt;Detectors are mounted on EST SIGA-SB bases in all common areas, and on EST SIGA-AB4G sounder bases in all guest rooms.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-IM addressable isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Credits==&lt;br /&gt;
Thank you to NSS for submitting this system!&lt;br /&gt;
&lt;br /&gt;
[[Category:Nova Scotia]]&lt;br /&gt;
[[Category:Holiday Inn]]&lt;br /&gt;
[[Category:Hotels]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
</feed>