<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hollis_Ford</id>
	<title>Hollis Ford - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hollis_Ford"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hollis_Ford&amp;action=history"/>
	<updated>2026-09-04T04:26:38Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Hollis_Ford&amp;diff=13869&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-350&lt;br /&gt;FACP Location: Main Entrance&lt;br /&gt;System Type: Single_Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: N/A&lt;br /&gt;Date of last known Upgrade: 2012&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1977, 2012 |}  &#039;&#039;&#039;Hollis Ford&#039;&#039;&#039; is a Ford dealership located at 266 Robie Street...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hollis_Ford&amp;diff=13869&amp;oldid=prev"/>
		<updated>2026-09-03T23:37:55Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FX-350&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single_Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2012&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1977, 2012 |}  &amp;#039;&amp;#039;&amp;#039;Hollis Ford&amp;#039;&amp;#039;&amp;#039; is a Ford dealership located at 266 Robie Street...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-350&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single_Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: 2012&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1977, 2012&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Hollis Ford&amp;#039;&amp;#039;&amp;#039; is a Ford dealership located at 266 Robie Street, in Truro, Nova Scotia, Canada.  The building was built in 1977, and was expanded in 2012.  The fire alarm system was upgraded during the 2012 expansion.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2012-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-350 addressable fire alarm system.  The panel is located at the main entrance.  The system runs Mircom&amp;#039;s TBD addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom BL-10A motor bells (10&amp;quot; gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401ID addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Credits==&lt;br /&gt;
Thank you to NSS for submitting this system!&lt;br /&gt;
&lt;br /&gt;
[[Category:Nova Scotia]]&lt;br /&gt;
[[Category:Dealerships]]&lt;br /&gt;
[[Category:Mircom]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
</feed>