<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hyatt_House_Tampa_Airport%2FWestshore_%28West%29</id>
	<title>Hyatt House Tampa Airport/Westshore (West) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Hyatt_House_Tampa_Airport%2FWestshore_%28West%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hyatt_House_Tampa_Airport/Westshore_(West)&amp;action=history"/>
	<updated>2026-04-19T09:53:25Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Hyatt_House_Tampa_Airport/Westshore_(West)&amp;diff=8874&amp;oldid=prev</id>
		<title>TwentyThree33 at 00:08, 26 May 2024</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hyatt_House_Tampa_Airport/Westshore_(West)&amp;diff=8874&amp;oldid=prev"/>
		<updated>2024-05-26T00:08:20Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:08, 25 May 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l33&quot;&gt;Line 33:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 33:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[Category:Florida]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[Category:Hotels]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Hyatt_House_Tampa_Airport/Westshore_(West)&amp;diff=7222&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030 w/DVC &lt;br /&gt;FACP Location: Lobby &lt;br /&gt;System Type: Addressable &lt;b...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Hyatt_House_Tampa_Airport/Westshore_(West)&amp;diff=7222&amp;oldid=prev"/>
		<updated>2024-02-01T21:44:51Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS2-3030 w/DVC &amp;lt;br /&amp;gt;FACP Location: Lobby &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;b...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS2-3030 w/DVC &amp;lt;br /&amp;gt;FACP Location: Lobby &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70VRMS (audible) &amp;lt;br&amp;gt; 24VDC (sounders &amp;amp; visual) &amp;lt;br /&amp;gt;System Coding: Unknown &amp;lt;br&amp;gt;Strobes Synchronized: Yes, SS &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2018&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Hyatt House&amp;#039;&amp;#039;&amp;#039; is a chain of hotels owned by Hyatt. This particular hotel is located at 5308 Avion Park Dr, Tampa, FL and is close to the Tampa International Airport. It is the west hotel of the two hotels of the same name. It was built in 2018, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2018-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Notifier NFS2-3030 addressable fire alarm system. The panel is located in the lobby. The system runs Notifier’s FlashScan addressable protocol, and is equipped with the Digital Voice Command (DVC) voice evacuation system. The tones and/or messages are unknown.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are from System Sensor’s “L-Series” line of products. &amp;lt;br&amp;gt; Most notification appliances are System Sensor SPSCWL speaker/strobes (white, ceiling-mount, set to 30cd). &amp;lt;br&amp;gt; Some areas have System Sensor SPSWL speaker/strobes (white, wall-mount, set to 15cd). &amp;lt;br&amp;gt; Areas requiring more audible coverage have System Sensor SPWL speakers (white, wall-mount. &amp;lt;br&amp;gt; There are System Sensor SWL remote strobes (white, wall-mount, set to 15cd) in each guest room’s bathroom.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FSP-951 addressable photoelectric smoke detectors throughout the building, mounted on System Sensor B300-6 bases.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.&lt;/div&gt;</summary>