		<id>https://firealarmpedia.org/index.php?title=La_Crete_Inn_%26_Suites&amp;diff=13471&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications (Main Building) |- |  |- | FACP: EST FireShield FS502G&lt;br /&gt;FACP Location: Behind Front Desk&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Continuous&lt;br&gt;Strobes Synchronized: Yes, Self-Sync&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2005 |}  &#039;&#039;&#039;La Crete Inn &amp; Suites&#039;&#039;&#039; is...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=La_Crete_Inn_%26_Suites&amp;diff=13471&amp;oldid=prev"/>
		<updated>2025-12-19T05:04:55Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications (Main Building) |- |  |- | FACP: EST FireShield FS502G&amp;lt;br /&amp;gt;FACP Location: Behind Front Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2005 |}  &amp;#039;&amp;#039;&amp;#039;La Crete Inn &amp;amp; Suites&amp;#039;&amp;#039;&amp;#039; is...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications (Main Building)&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST FireShield FS502G&amp;lt;br /&amp;gt;FACP Location: Behind Front Desk&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Self-Sync&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2005&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;La Crete Inn &amp;amp; Suites&amp;#039;&amp;#039;&amp;#039; is an independent hotel located at 10101 101 St, in La Crete, Alberta, Canada.  The hotel consists of 2 buildings.  The main building was built in 2005, and Building 3 was built in 2011.  The fire alarm systems are original to both buildings.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (Main Building)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST FireShield FS502G conventional fire alarm system.  The panel is located behind the front desk.  The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 439D-6AWC vibrating bells (6&amp;quot; gong) mounted on Edwards 403-5A-R strobe plates (15cd).  &amp;lt;br&amp;gt;The lobby has Edwards 439D-10AWC vibrating bells (10&amp;quot; gong) mounted on Edwards 403-5A-R strobe plates (15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor 1400A conventional ionization smoke detectors throughout the main floor.  &amp;lt;br&amp;gt;There are Edwards EC30U-3 conventional photoelectric smoke detectors throughout the second floor.  &amp;lt;br&amp;gt;There are Edwards 281B-PL conventional 135°F fixed-temperature/rate-of-rise heat detectors in some rooms and at the top of each stairwell.  &amp;lt;br&amp;gt;There is an Edwards 284B-PL conventional 194°F fixed-temperature heat detector in the laundry room.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (Building 3)==&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FX-2000&amp;lt;br /&amp;gt;FACP Location: Central Stairwell&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Mircom&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2011&lt;br /&gt;
|}&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FX-2000 addressable fire alarm system.  The panel is located in the central stairwell.  The system runs Mircom&amp;#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All common areas have Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-340R horn/strobes (red, wall-mount, set to electromechanical/15cd).  &amp;lt;br&amp;gt;All guest rooms have Mircom MH-S25WA silenceable mini-horns (white).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401AD addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout all common areas.  &amp;lt;br&amp;gt;There are Mircom MIX-5251HA addressable 190°F fixed-temperature heat detectors in the laundry room.  &amp;lt;br&amp;gt;All detectors are mounted on System Sensor B210LPA bases.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all signal circuits.&lt;br /&gt;