<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Macleod_Place</id>
	<title>Macleod Place - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Macleod_Place"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Macleod_Place&amp;action=history"/>
	<updated>2026-04-28T01:59:16Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Macleod_Place&amp;diff=12890&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Tyco/Grinnell Series M-1000 &lt;br /&gt;FACP Location: Multiple, see FACP &lt;br /&gt;System Type: Single-Stage Conventional &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: No &lt;br /&gt;Date of last known Upgrade: 2002 &lt;br /&gt;Most Recent Known Modification: 2010s, Smokes &lt;br /&gt;Year Opened: 1971 |}  &#039;&#039;&#039;Macleod Place&#039;&#039;&#039; is a set of two...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Macleod_Place&amp;diff=12890&amp;oldid=prev"/>
		<updated>2025-06-17T03:53:32Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Tyco/Grinnell Series M-1000 &amp;lt;br /&amp;gt;FACP Location: Multiple, see FACP &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: 2002 &amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, Smokes &amp;lt;br /&amp;gt;Year Opened: 1971 |}  &amp;#039;&amp;#039;&amp;#039;Macleod Place&amp;#039;&amp;#039;&amp;#039; is a set of two...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Tyco/Grinnell Series M-1000 &amp;lt;br /&amp;gt;FACP Location: Multiple, see FACP &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: 2002 &amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s, Smokes &amp;lt;br /&amp;gt;Year Opened: 1971&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Macleod Place&amp;#039;&amp;#039;&amp;#039; is a set of two office buildings located at 5920 Macleod Trail SW, Calgary, AB. The complex was built in 1971, and the fire alarm system was upgraded in 2002.&lt;br /&gt;
&lt;br /&gt;
== System Specifications ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The complex is protected by a Tyco/Grinnell Series M-1000 conventional fire alarm system. There are three panels, located in the following:&lt;br /&gt;
* Rear hallway exit of I&lt;br /&gt;
* Parkade electrical room of II&lt;br /&gt;
* Penthouse electrical room &amp;lt;br&amp;gt;&lt;br /&gt;
Each panel supervises its respective area, and are wired to trip each other when one goes into alarm. The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Mircom &amp;quot;Select-a-Horn/Strobe&amp;quot; FHS-240R horn/strobes (red, wall-mount, 15cd/electromechanical).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
Most pull stations are the original Simplex 4251-20 conventional single-action pull stations. &amp;lt;br&amp;gt; There are Mircom MS-401 conventional single-action pull stations as deficiency replacements.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors at the top of the stairwell and in some other areas. &amp;lt;br&amp;gt; There are FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors in the telephone/electrical rooms and mechanical room. &amp;lt;br&amp;gt; One server room has a Simplex 4098-9615 conventional 200°F fixed-temperature/rate-of-rise heat detector. &amp;lt;br&amp;gt; There is a mix of FDD CF-135 and System Sensor 5603A conventional 135°F fixed-temperature heat detectors throughout the parkade.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Mircom MP-300 end-of-line resistor plates on all circuits.&lt;br /&gt;