<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Mayland_House</id>
	<title>Mayland House - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Mayland_House"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Mayland_House&amp;action=history"/>
	<updated>2026-04-27T17:01:33Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Mayland_House&amp;diff=13481&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS4&lt;br /&gt;FACP Location: Main Floor Office/Server Room&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Genesis&lt;br /&gt;System Installed: 2025&lt;br /&gt;Most Recent Known Modification: Duct Smoke&lt;br /&gt;Year Opened: 1959 |}  NOTE: This is an hobby system, and is not an...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Mayland_House&amp;diff=13481&amp;oldid=prev"/>
		<updated>2025-12-19T05:09:55Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST QuickStart QS4&amp;lt;br /&amp;gt;FACP Location: Main Floor Office/Server Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;System Installed: 2025&amp;lt;br /&amp;gt;Most Recent Known Modification: Duct Smoke&amp;lt;br /&amp;gt;Year Opened: 1959 |}  NOTE: This is an hobby system, and is not an...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QS4&amp;lt;br /&amp;gt;FACP Location: Main Floor Office/Server Room&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;System Installed: 2025&amp;lt;br /&amp;gt;Most Recent Known Modification: Duct Smoke&amp;lt;br /&amp;gt;Year Opened: 1959&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
NOTE: This is an hobby system, and is not an official fire alarm system.  This system is installed in a private residence, therefore it does not need to meet CAN-ULC codes.&lt;br /&gt;
&lt;br /&gt;
The &amp;#039;&amp;#039;&amp;#039;Mayland House&amp;#039;&amp;#039;&amp;#039; is a private residence located in Northeast Calgary, Alberta, Canada.  The house was built in 1959, and the fire alarm system was installed in 2025.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The house is protected by an EST QuickStart QS4 addressable fire alarm system.  The panel is located in the main floor office/server room.  The system runs EST&amp;#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are EST &amp;quot;Genesis&amp;quot; G1R-HOV15 horn/strobes (red, wall-mount, no marking, 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors in all bedrooms, the office, and all corridors and common areas.  &amp;lt;br&amp;gt;There are EST SIGA-HRS addressable 135°F fixed-temperature/rate-of-rise heat detectors in the washroom and kitchen.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on EST SIGA-SB bases.  &amp;lt;br&amp;gt;There is an EST &amp;quot;SuperDuct&amp;quot; SIGA-SD addressable photoelectric duct smoke detector on the furnace duct.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There is an EST SIGA-CR addressable relay module for furnace shutdown.  &amp;lt;br&amp;gt;There is an EST &amp;quot;Genesis SignalMaster&amp;quot; G1M-RM signal control module installed on NACs 1 and 2 for 4-wire operation and strobe synchronization.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
None currently present.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Hobby Systems]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>