<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=McDonald%27s_%28Clearview%29</id>
	<title>McDonald&#039;s (Clearview) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=McDonald%27s_%28Clearview%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=McDonald%27s_(Clearview)&amp;action=history"/>
	<updated>2026-04-27T22:26:05Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=McDonald%27s_(Clearview)&amp;diff=12509&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Simplex 4008 &lt;br /&gt;FACP Location: Main Entrance Vestibule &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, SmartSync &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Year Opened: 2015 |}   &#039;&#039;&#039;McDonald’s&#039;&#039;&#039; is a fast food restaurant chain. This particular restaurant is locat...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=McDonald%27s_(Clearview)&amp;diff=12509&amp;oldid=prev"/>
		<updated>2025-04-06T06:11:59Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4008 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2015 |}   &amp;#039;&amp;#039;&amp;#039;McDonald’s&amp;#039;&amp;#039;&amp;#039; is a fast food restaurant chain. This particular restaurant is locat...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4008 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;McDonald’s&amp;#039;&amp;#039;&amp;#039; is a fast food restaurant chain. This particular restaurant is located at 16 Conway St, Red Deer, Alberta. The restaurant opened in 2015, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2015-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Simplex 4008 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex&amp;#039;s IDNet addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Simplex &amp;quot;TrueAlert&amp;quot; 4906-9127 horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Simplex 4099-9001 addressable single-action pull stations. &lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 4090-9001 addressable monitor modules supervising the kitchen suppression system, and the sprinkler system&amp;#039;s tamper and flow switches. &lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 2081-9040C end-of-line resistor plates on all sprinkler, suppression and signal circuits. &lt;br /&gt;
&lt;br /&gt;
[[Category:Red Deer]]&lt;br /&gt;
[[Category:Restaurants]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>