	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Namao158&amp;diff=13326&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: EST iO500&lt;br /&gt;FACP Location: Main Lobby&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Genesis&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2012 |}  &#039;&#039;&#039;Namao158&#039;&#039;&#039; is a small retail/office building located at 15823 97 St...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Namao158&amp;diff=13326&amp;oldid=prev"/>
		<updated>2025-09-05T01:32:33Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: EST iO500&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2012 |}  &amp;#039;&amp;#039;&amp;#039;Namao158&amp;#039;&amp;#039;&amp;#039; is a small retail/office building located at 15823 97 St...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST iO500&amp;lt;br /&amp;gt;FACP Location: Main Lobby&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2012&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Namao158&amp;#039;&amp;#039;&amp;#039; is a small retail/office building located at 15823 97 St NW, in Edmonton, Alberta, Canada.  The building was built in 2012, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an EST iO500 addressable fire alarm system.  The panel is located in the main lobby.  The system runs EST&amp;#039;s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Booster Panels=====&lt;br /&gt;
There is likely an Edwards BPS6AC 6-amp booster power supply on the system.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are EST SIGA-PS addressable photoelectric smoke detectors in some areas, mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules serving various purposes.  &amp;lt;br&amp;gt;There are EST SIGA-IM addressable isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Strip Malls]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>