<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=OHSU_Mark_O._Hatfield_Research_Center</id>
	<title>OHSU Mark O. Hatfield Research Center - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=OHSU_Mark_O._Hatfield_Research_Center"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=OHSU_Mark_O._Hatfield_Research_Center&amp;action=history"/>
	<updated>2026-04-07T09:15:28Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=OHSU_Mark_O._Hatfield_Research_Center&amp;diff=10251&amp;oldid=prev</id>
		<title>Somedudewithanexitsign: This was basically the same system as the children&#039;s hospital</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=OHSU_Mark_O._Hatfield_Research_Center&amp;diff=10251&amp;oldid=prev"/>
		<updated>2024-09-04T02:41:20Z</updated>

		<summary type="html">&lt;p&gt;This was basically the same system as the children&amp;#039;s hospital&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100+&lt;br /&gt;
FACP Location: Unknown &amp;lt;br /&amp;gt;&lt;br /&gt;
System Type: Addressable &amp;lt;br /&amp;gt;&lt;br /&gt;
System Line Voltage: 120VAC&amp;lt;br /&amp;gt;&lt;br /&gt;
NAC Voltage: 24VDC &amp;lt;br /&amp;gt;&lt;br /&gt;
System Coding: 20BPM March Time&amp;lt;br /&amp;gt;&lt;br /&gt;
Strobes Synchronized No &amp;lt;br&amp;gt;&lt;br /&gt;
Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;&lt;br /&gt;
Year Opened: 1998&lt;br /&gt;
|}&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;OHSU Mark O. Hatfield Research Center&amp;#039;&amp;#039;&amp;#039; is a Healthcare Facility ran by Oregon Heath and Science University Located at 3250 SW Sam Jackson Park Rd, Portland, OR&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
===FACP===&lt;br /&gt;
The building is protected by a Simplex 4100+ fire alarm system. The panel is location is unknown. The system runs Simplex&amp;#039;s MAPNET II addressable protocol, and the system coding is 20BPM March Time.&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There are are Simplex 4603-9101 annunciators.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Wheelock CH-DF1-24-LSM chime/strobes (red, wall-mount, 15/75cd), with some Wheelock RS-24-1575-VFR chime/strobes (red, wall-mount, 15/75cd).&lt;br /&gt;
&lt;br /&gt;
There are Wheelock CH70-24MCW-FR chime/strobes (red, wall-mount, set to 15cd) as deficiency replacements.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Simplex 2099-9795 addressable single-action pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
All smoke detectors are Simplex &amp;#039;TrueAlarm&amp;#039; 4098-9701 addressable photoelectric smoke detectors on Simplex 4098-9784 bases.&lt;br /&gt;