<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=OHSU_Peter_O._Kohler_Pavilion</id>
	<title>OHSU Peter O. Kohler Pavilion - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=OHSU_Peter_O._Kohler_Pavilion"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=OHSU_Peter_O._Kohler_Pavilion&amp;action=history"/>
	<updated>2026-04-07T09:03:27Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=OHSU_Peter_O._Kohler_Pavilion&amp;diff=10250&amp;oldid=prev</id>
		<title>Somedudewithanexitsign: Another OHSU Page Done.</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=OHSU_Peter_O._Kohler_Pavilion&amp;diff=10250&amp;oldid=prev"/>
		<updated>2024-09-04T02:33:39Z</updated>

		<summary type="html">&lt;p&gt;Another OHSU Page Done.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4100U &amp;lt;br /&amp;gt;&lt;br /&gt;
FACP Location: Unknown &amp;lt;br /&amp;gt;&lt;br /&gt;
System Type: Addressable &amp;lt;br /&amp;gt; &lt;br /&gt;
System Line Voltage: 120VAC&amp;lt;br /&amp;gt;&lt;br /&gt;
NAC Voltage: 24VDC &amp;lt;br /&amp;gt;&lt;br /&gt;
System Tone: Chime &amp;lt;br /&amp;gt;&lt;br /&gt;
Strobes Synchronized Yes, Wheelock &amp;lt;br&amp;gt;&lt;br /&gt;
Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;&lt;br /&gt;
Year Opened: 2006&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;OHSU Peter O. Kohler Pavilion&amp;#039;&amp;#039;&amp;#039; is a healthcare facility ran by Oregon Heath and Science University, This building  is located at 808 SW Campus Dr, Portland, OR&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
===FACP===&lt;br /&gt;
The building is protected by a Simplex 4100U Addressable fire alarm system.  The panel location is unknown.  The system runs IDNet addressable protocol, and the system tone is chime.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock E70-24MCW-FW Speaker Strobes (White, Wall-Mount, set on 15cd). There are a few Wheelock E70-241575W-FW Speaker Strobes (White, Wall-Mount, 15/75cd). There are a Wheelock RSS-24MCW Strobes (White, Wall-Mount, set on 15cd) located in small rooms and spaces that need extra strobe coverage. The Arial Tram Station has Wheelock ET70WP-241575W-FR Weatherproof Speaker Strobes (Red, Wall-Mount, 15/75cd) and the arial tram stairway has Wheelock E70-W Speakers (White, Wall-Mount)&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are a mixture of Simplex 40999-9001 Single Action Addressable Pull Stations and Simplex 4099-9003 Dual Action Addressable pull stations.&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
&lt;br /&gt;
All Smoke Detectors are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9714 Photoelectric Smoke Detectors on Simplex 4098-9792 Bases&lt;br /&gt;