<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Palihotel_Seattle</id>
	<title>Palihotel Seattle - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Palihotel_Seattle"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Palihotel_Seattle&amp;action=history"/>
	<updated>2026-04-07T11:40:57Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Palihotel_Seattle&amp;diff=12016&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &lt;br /&gt;FACP Location: Electrical Room? &lt;br /&gt;System Type: Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: 2018 &lt;br /&gt;Year Opened: 1898 |}  &#039;&#039;&#039;Palihotel&#039;&#039;&#039; is a chain of boutique hotels in the United States.  They are owned by the Palisociety....&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Palihotel_Seattle&amp;diff=12016&amp;oldid=prev"/>
		<updated>2025-01-12T19:55:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Electrical Room? &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2018 &amp;lt;br /&amp;gt;Year Opened: 1898 |}  &amp;#039;&amp;#039;&amp;#039;Palihotel&amp;#039;&amp;#039;&amp;#039; is a chain of boutique hotels in the United States.  They are owned by the Palisociety....&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3 &amp;lt;br /&amp;gt;FACP Location: Electrical Room? &amp;lt;br /&amp;gt;System Type: Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2018 &amp;lt;br /&amp;gt;Year Opened: 1898&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Palihotel&amp;#039;&amp;#039;&amp;#039; is a chain of boutique hotels in the United States.  They are owned by the Palisociety.  This particular hotel is located at 107 Pine St, Seattle, Washington, and is situated in the historic Colonnade Hotel Building, which was built in 1898.  The building became Palihotel in 2018, and received a new fire alarm system at that time.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system.  The panel is likely located in an electrical room.  The system runs EST’s Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is an Edwards EST3-LCDANN annunciator in the lobby.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
The common areas of the hotel have System Sensor “L-Series” PC2WL horn/strobes (white, ceiling-mount, set to 15/75cd).  &amp;lt;br&amp;gt; The guest rooms have System Sensor “SpectrAlert Advance” HW-LF low frequency sounders (white, wall-mount), as well as sounders, see below for more information.&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGA-278 addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Edwards SIGA-PD addressable optical smoke detectors throughout the hotel.  They are mounted on Edwards SIGA-SB in common areas, and on EST SIGA-AB4G-LF low-frequency sounder bases in the guest rooms.&lt;br /&gt;