<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Publix_%28Treasure_Island%29</id>
	<title>Publix (Treasure Island) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Publix_%28Treasure_Island%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Publix_(Treasure_Island)&amp;action=history"/>
	<updated>2026-04-27T19:45:36Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Publix_(Treasure_Island)&amp;diff=9683&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: ADT Unimode 200 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addressa...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Publix_(Treasure_Island)&amp;diff=9683&amp;oldid=prev"/>
		<updated>2024-07-09T06:15:54Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: ADT Unimode 200 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressa...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: ADT Unimode 200 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Wheelock &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Year Opened: 2006&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Publix&amp;#039;&amp;#039;&amp;#039; is an American supermarket chain headquartered in Lakeland, Florida.  This particular store is located at 111 104th Avenue, in Treasure Island, Florida, USA.  The store was built in 2006, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an ADT Unimode 200 addressable fire alarm system.  The panel location is unknown.  The system runs ADT’s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Wheelock AS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd).  &amp;lt;br&amp;gt;Areas requiring additional visual coverage have Wheelock RSS-24MCW-FR remote strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are ADT ADT-BG12LX addressable dual-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are ADT M300ADT addressable monitor modules supervising the sprinkler system’s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
[[Category:Florida]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;/div&gt;</summary>