		<id>https://firealarmpedia.org/index.php?title=RONA_(Sunridge)&amp;diff=9997&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Kidde VS4 &lt;br /&gt;FACP Location: Main Entrance Vestibule &lt;br /&gt;System Type: Single-Stag...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=RONA_(Sunridge)&amp;diff=9997&amp;oldid=prev"/>
		<updated>2024-08-04T21:23:49Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Kidde VS4 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stag...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Kidde VS4 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis &amp;lt;br /&amp;gt;Date of last known Upgrade: 2024 &amp;lt;br /&amp;gt;Year Opened: 1998&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;RONA&amp;#039;&amp;#039;&amp;#039; is a Canadian hardware store chain. This particular store is located at 2665 32 St NE, Calgary, Alberta. The store opened in 1998, and the fire alarm system was upgraded in 2024.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2024-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Kidde VS4 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Kidde’s GSA addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Kidde “Genesis” G4AVRN horn/strobes (red, wall-mount, no marking, set to 15cd). &lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Kidde GSA-M270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed. The building has a sprinkler system.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Kidde GSA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt; There are Kidde GSA-CR addressable relay modules serving various purposes. &amp;lt;br&amp;gt; There are Kidde GSA-IM isolator modules on the SLC’s.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Edwards EOL-P1 end-of-line resistors on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
== Former System Specifications (1998-2024) ==&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST2 &amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: 2010s? &amp;lt;br/&amp;gt; Year Installed: 1998 &amp;lt;br /&amp;gt;Year Decommissioned: 2024&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building was protected by an Edwards EST2 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Edwards’ Signature addressable protocol, and the system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
Most notification appliances were General Signal MB10-24 motor bells (10” gong) mounted on Edwards 403-5A-R strobe plates (15cd). &amp;lt;br&amp;gt; There was one Edwards MB10-24 motor bell (10” gong) on the existing strobe plate as a deficiency replacement. &amp;lt;br&amp;gt; One bell was on a Wheelock RSSP-24MCW strobe plate (red, set to 15cd) as a deficiency replacement.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations were EST SIGA-270 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed. The building has a sprinkler system.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There were EST SIGA-WTM addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  &amp;lt;br&amp;gt; There were EST SIGA-CR addressable relay modules serving various purposes. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There were Edwards EOL-P1 end-of-line resistors on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
== Permits ==&lt;br /&gt;
&lt;br /&gt;
 Permit issued May 6, 2024.  Project scope was Fire Alarm Repair/Upgrade. Source: Calgary MyProperty &lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;