<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre</id>
	<title>Ramada by Wyndham Belleville Harbourview Conference Centre - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre&amp;action=history"/>
	<updated>2026-04-27T20:57:17Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre&amp;diff=11017&amp;oldid=prev</id>
		<title>Alberta Fire Alarms at 16:02, 11 October 2024</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre&amp;diff=11017&amp;oldid=prev"/>
		<updated>2024-10-11T16:02:19Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 10:02, 11 October 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l27&quot;&gt;Line 27:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 27:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Edwards C2M-PD conventional photoelectric smoke detectors throughout all common areas.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135-degree fixed-temperature/rate-of-rise heat detectors in most guest rooms.  &amp;lt;br&amp;gt;Some guest rooms have Edwards 245A conventional 135-degree fixed-temperature heat detectors.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;There are Edwards C2M-PD conventional photoelectric smoke detectors throughout all common areas.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135-degree fixed-temperature/rate-of-rise heat detectors in most guest rooms.  &amp;lt;br&amp;gt;Some guest rooms have Edwards 245A conventional 135-degree fixed-temperature heat detectors.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==== EOLs ====&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;There are Edwards EOL-P1 end-of-line resistor plates on all circuits.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Ontario]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Ontario]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Hotels]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Hotels]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre&amp;diff=10217&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000 &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Conventio...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Ramada_by_Wyndham_Belleville_Harbourview_Conference_Centre&amp;diff=10217&amp;oldid=prev"/>
		<updated>2024-09-03T03:58:01Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Conventio...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000 &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Continuous? &amp;lt;br&amp;gt;Strobes Synchronized: N/A &amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s &amp;lt;br /&amp;gt;Year Opened: 1971&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Ramada&amp;#039;&amp;#039;&amp;#039; is a chain of budget hotels owned by Wyndham.  This particular hotel is located at 11 Bay Bridge Road, in Belleville, Ontario, Canada.  The hotel was built in 1971, and became a Ramada in 1984.  The fire alarm system is partially original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2000s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel location is unknown.  The system coding is likely continuous.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Mircom RAM-1032TZDS annunciator in the main entrance vestibule, mounted in a Mircom BB-1001 enclosure.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 439D-6AWC vibrating bells (6” gong).  &amp;lt;br&amp;gt;Some areas have Simplex 2901-9723 motor bells (6” gong).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Most pull stations are Edwards 270-SPO conventional single-action pull stations.  &amp;lt;br&amp;gt;Some areas have Cincinnati 13525 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Edwards C2M-PD conventional photoelectric smoke detectors throughout all common areas.  &amp;lt;br&amp;gt;There are FDD CR-135 conventional 135-degree fixed-temperature/rate-of-rise heat detectors in most guest rooms.  &amp;lt;br&amp;gt;Some guest rooms have Edwards 245A conventional 135-degree fixed-temperature heat detectors.&lt;br /&gt;
&lt;br /&gt;
[[Category:Ontario]]&lt;br /&gt;
[[Category:Hotels]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>