<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Real_Canadian_Superstore_%28South_Edmonton_Common%29</id>
	<title>Real Canadian Superstore (South Edmonton Common) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Real_Canadian_Superstore_%28South_Edmonton_Common%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Real_Canadian_Superstore_(South_Edmonton_Common)&amp;action=history"/>
	<updated>2026-04-08T16:35:42Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Real_Canadian_Superstore_(South_Edmonton_Common)&amp;diff=11641&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &lt;br /&gt;FACP Location: Exit Vestibule &lt;br /&gt;System Type: Single Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, System Sensor &lt;br /&gt;Date of last known Upgrade: 2022 &lt;br /&gt;Year Opened: 2000 |}   &#039;&#039;&#039;Real Canadian Superstore&#039;&#039;&#039; is a chain of supermarkets owned by Loblaws. This parti...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Real_Canadian_Superstore_(South_Edmonton_Common)&amp;diff=11641&amp;oldid=prev"/>
		<updated>2024-11-12T04:36:57Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Exit Vestibule &amp;lt;br /&amp;gt;System Type: Single Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2022 &amp;lt;br /&amp;gt;Year Opened: 2000 |}   &amp;#039;&amp;#039;&amp;#039;Real Canadian Superstore&amp;#039;&amp;#039;&amp;#039; is a chain of supermarkets owned by Loblaws. This parti...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier NFS-320C &amp;lt;br /&amp;gt;FACP Location: Exit Vestibule &amp;lt;br /&amp;gt;System Type: Single Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, System Sensor &amp;lt;br /&amp;gt;Date of last known Upgrade: 2022 &amp;lt;br /&amp;gt;Year Opened: 2000&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Real Canadian Superstore&amp;#039;&amp;#039;&amp;#039; is a chain of supermarkets owned by Loblaws. This particular store is located at  9711 23 Ave NW, Edmonton, AB. The store opened in 2000, and the fire alarm system was upgraded in 2022; the pull stations are original.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (2022-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the exit vestibule. The system runs Notifier’s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, set to 15cd/electromechanical).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations but one are Notifier NFM-950B conventional single-action pull stations, wired to Notifier MMX-101A addressable monitor modules. &amp;lt;br&amp;gt; There is a Notifier NBG-12LX addressable dual-action pull station in the exit vestibule as a deficiency replacement.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier MMX-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. &amp;lt;br&amp;gt; There is a Notifier ISO-XA isolator module on the SLC.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
== Former System Specifications (2000-2022) ==&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier AFP-200 &amp;lt;br /&amp;gt;FACP Location: Exit Vestibule &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Continuous &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br/&amp;gt; Year Installed: 2000 &amp;lt;br /&amp;gt;Year Decommissioned: 2022&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building was protected by a Notifier AFP-200 addressable fire alarm system. The panel was located in the exit vestibule. The system ran Notifier’s CLIP addressable protocol, and the system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances were Notifier KMS-10-24VDC/P motor bells (10” gong) mounted on Wheelock RSSP-2415W strobe plates (red, 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations, wired to Notifier MMX-101A addressable monitor modules. These are still in service on the current system.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier MMX-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. They are still in service.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits, still in use on the current system. &lt;br /&gt;
&lt;br /&gt;
[[Category:Edmonton]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>