<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Red_Deer_Public_Library_%28Central_Branch%29</id>
	<title>Red Deer Public Library (Central Branch) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Red_Deer_Public_Library_%28Central_Branch%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Red_Deer_Public_Library_(Central_Branch)&amp;action=history"/>
	<updated>2026-04-28T00:53:02Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Red_Deer_Public_Library_(Central_Branch)&amp;diff=12849&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Simplex 4007ES &lt;br /&gt;FACP Location: Unknown &lt;br /&gt;System Type: Single-Stage Addressable &lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC &lt;br /&gt;System Coding: Temporal &lt;br&gt;Strobes Synchronized: Yes, SmartSync &lt;br /&gt;Date of last known Upgrade: 2023 &lt;br /&gt;Most Recent Known Modification: N/A &lt;br /&gt; Year Opened: 1967 |}  &#039;&#039;&#039;Red Deer Public Library&#039;&#039;&#039; is a public library system f...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Red_Deer_Public_Library_(Central_Branch)&amp;diff=12849&amp;oldid=prev"/>
		<updated>2025-06-07T23:48:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Simplex 4007ES &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync &amp;lt;br /&amp;gt;Date of last known Upgrade: 2023 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1967 |}  &amp;#039;&amp;#039;&amp;#039;Red Deer Public Library&amp;#039;&amp;#039;&amp;#039; is a public library system f...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Simplex 4007ES &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Addressable &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: Yes, SmartSync &amp;lt;br /&amp;gt;Date of last known Upgrade: 2023 &amp;lt;br /&amp;gt;Most Recent Known Modification: N/A &amp;lt;br /&amp;gt; Year Opened: 1967&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Red Deer Public Library&amp;#039;&amp;#039;&amp;#039; is a public library system for Red Deer. This page will cover the Central Branch, located at 4818 49 St, Red Deer, Alberta. The library was built in 1967, and a second floor was added in 1979. The fire alarm system was upgraded in 2023.&lt;br /&gt;
&lt;br /&gt;
== System Specifications ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a Simplex 4007ES addressable fire alarm system. The panel location is unknown. The system runs Simplex&amp;#039;s IDNet addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There is a Simplex 4606-9202 annunciator paired with two Simplex 4606-9101 annunciators in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances are Simplex &amp;quot;TrueAlert&amp;quot; 4901-9820 horns (red, wall-mount) mounted right next to Simplex 4906-9101 remote strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Simplex 4099-9004 addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex &amp;quot;TrueAlarm&amp;quot; 4098-9714 addressable photoelectric smoke detectors throughout the building, mounted on Simplex 4098-9792 bases. &amp;lt;br&amp;gt; The return air-units have Simplex 4098-9755 addressable duct smoke detector housings with Simplex 4098-9714 addressable photoelectric heads.&lt;br /&gt;
&lt;br /&gt;
==== Modules ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 4090-9002 addressable relay modules serving various purposes. &amp;lt;br&amp;gt; There are Simplex 4090-9116 addressable isolator modules on the SLC.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There are Simplex 2081-9040C end-of-line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
== Former System Specifications ==&lt;br /&gt;
&lt;br /&gt;
{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Former System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: EST QuickStart QSC &amp;lt;br /&amp;gt;FACP Location: Unknown &amp;lt;br /&amp;gt;System Type: Single-Stage Conventional &amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR &amp;lt;br /&amp;gt;System Coding: Temporal &amp;lt;br&amp;gt;Strobes Synchronized: No &amp;lt;br /&amp;gt; Most Recent Known Modification: Early 2010s (FACP and detectors) &amp;lt;br/&amp;gt;Year Installed: Late 1990s &amp;lt;br /&amp;gt;Year Decommissioned: 2023&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building was protected by an EST QuickStart QSC conventional fire alarm system. The panel location was unknown. The system coding was continuous.&lt;br /&gt;
&lt;br /&gt;
===== Annunciators =====&lt;br /&gt;
&lt;br /&gt;
There was an EST QSA-1-S cabinet with an EST QSC-CPU-1 annunciator and SL30 zone card in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
All notification appliances were Edwards 439D-10AWC vibrating bells (10&amp;quot; gong) mounted right next to Edwards &amp;quot;Integrity&amp;quot; 202-5A-001 remote strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
All pull stations are Edwards 270-SPO conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There were Edwards C2M-PD conventional photoelectric smoke detectors throughout the building. &amp;lt;br&amp;gt; The return-air units had Edwards &amp;quot;SuperDuct&amp;quot; SD-2W conventional photoelectric duct smoke detectors.&lt;br /&gt;
&lt;br /&gt;
==== EOLs ====&lt;br /&gt;
&lt;br /&gt;
There were Edwards EOL-P1 end-of-line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;