<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=River_Park_Christian_Reformed_Church</id>
	<title>River Park Christian Reformed Church - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=River_Park_Christian_Reformed_Church"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=River_Park_Christian_Reformed_Church&amp;action=history"/>
	<updated>2026-09-04T05:36:42Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=River_Park_Christian_Reformed_Church&amp;diff=13934&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier AFP-200&lt;br /&gt;FACP Location: Main Entrance&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VDC&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: 2004&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1957, 1964, 2004 |}  &#039;&#039;&#039;River City Christian Reformed Church&#039;&#039;&#039; is a church loca...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=River_Park_Christian_Reformed_Church&amp;diff=13934&amp;oldid=prev"/>
		<updated>2026-09-03T23:55:26Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier AFP-200&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2004&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1957, 1964, 2004 |}  &amp;#039;&amp;#039;&amp;#039;River City Christian Reformed Church&amp;#039;&amp;#039;&amp;#039; is a church loca...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier AFP-200&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VDC&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2004&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1957, 1964, 2004&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;River City Christian Reformed Church&amp;#039;&amp;#039;&amp;#039; is a church located at 3818 14A St SW, in Calgary, Alberta, Canada.  The building was built in 1957, and was expanded in 1964 and 2004.  The fire alarm system was upgraded as part of the 2004 expansion.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2004-present)==&lt;br /&gt;
Please note that this information is accurate to 2021.&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier AFP-200 addressable fire alarm system.  The panel is located at the main entrance.  The system runs Notifier&amp;#039;s CLIP addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are System Sensor &amp;quot;SpectrAlert&amp;quot; P1224MCA horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier MPS-950B conventional single-action pull stations, wired to Notifier FMM-101A addressable monitor modules.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Notifier FSI-851A conventional ionization smoke detectors in some areas.  &amp;lt;br&amp;gt;There are Notifier FST-851A conventional 135°F fixed-temperature heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Notifier B710LPA bases.  &amp;lt;br&amp;gt;There is a Notifier &amp;quot;Innovair&amp;quot; FSD-751PLA addressable photoelectric duct smoke detector on the makeup air unit.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Calgary]]&lt;br /&gt;
[[Category:Places of Worship]]&lt;br /&gt;