	<entry>
		<id>https://firealarmpedia.org/index.php?title=Riverstone_Place&amp;diff=13064&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Notifier System 500&lt;br /&gt;FACP Location: Main Entrance&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Continuous&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1997 |}    &#039;&#039;&#039;Riverstone Place&#039;&#039;&#039; is a small retail/office plaza located a...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Riverstone_Place&amp;diff=13064&amp;oldid=prev"/>
		<updated>2025-08-04T21:04:07Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1997 |}    &amp;#039;&amp;#039;&amp;#039;Riverstone Place&amp;#039;&amp;#039;&amp;#039; is a small retail/office plaza located a...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Notifier System 500&amp;lt;br /&amp;gt;FACP Location: Main Entrance&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Continuous&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1997&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Riverstone Place&amp;#039;&amp;#039;&amp;#039; is a small retail/office plaza located at 830 Main Street, in Canmore, Alberta, Canada. The building was built in 1997, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Notifier System 500 conventional fire alarm system. The panel is located at the main entrance. The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock MIZ-24-LSM mini-horn/strobes (red, wall-mount, 15cd).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Notifier NFM-950B conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor C2W-BA conventional photoelectric smoke detectors at the top of each stairwell.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Notifier EOL-CR end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Alberta]]&lt;br /&gt;