<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=SOCO_Towers</id>
	<title>SOCO Towers - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=SOCO_Towers"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=SOCO_Towers&amp;action=history"/>
	<updated>2026-04-27T22:21:38Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=SOCO_Towers&amp;diff=13417&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Siemens Desigo&lt;br /&gt;FACP Location: Various&lt;br /&gt;System Type: Single-Stage Networked Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70.7VRMS&lt;br /&gt;System Coding: Temporal Tone?&lt;br&gt;Strobes Synchronized: N/A&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2024 |}  &#039;&#039;&#039;SOCO Towers&#039;&#039;&#039; is a residential complex located at 318 Al...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=SOCO_Towers&amp;diff=13417&amp;oldid=prev"/>
		<updated>2025-11-07T03:08:50Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Siemens Desigo&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Single-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS&amp;lt;br /&amp;gt;System Coding: Temporal Tone?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2024 |}  &amp;#039;&amp;#039;&amp;#039;SOCO Towers&amp;#039;&amp;#039;&amp;#039; is a residential complex located at 318 Al...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Siemens Desigo&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Single-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS&amp;lt;br /&amp;gt;System Coding: Temporal Tone?&amp;lt;br&amp;gt;Strobes Synchronized: N/A&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2024&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;SOCO Towers&amp;#039;&amp;#039;&amp;#039; is a residential complex located at 318 Alderson Ave, in Coquitlam, British Columbia, Canada.  The complex was built in 2024, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The complex is protected by a Siemens Desigo Fire Safety Modular addressable fire alarm system.  This is a networked system; there are nodes in the lobby of each building, and there are likely additional nodes in some electrical rooms.  The system runs Siemens&amp;#039; FirePrint addressable protocol, and is equipped with voice evacuation.  The evacuation signal is likely a temporal tone.  &amp;lt;br&amp;gt;The sequence of operation is not known, and this system may evacuate per-tower.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are System Sensor &amp;quot;L-Series&amp;quot; SCWLA remote speakers (white, ceiling-mount, set to 70V).  &amp;lt;br&amp;gt;The parkade has Siemens SLSPWR-F remote speakers (red, wall-mount, set to 70V).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Siemens HMS-SA addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are Siemens FDO421 addressable photoelectric smoke detectors throughout all common areas, in each elevator lobby, and at the top of each stairwell.  &amp;lt;br&amp;gt;There are Siemens FDT421 addressable heat detectors in some areas.  &amp;lt;br&amp;gt;All aforementioned detectors are mounted on Siemens DB-11 bases.  &amp;lt;br&amp;gt;There are Siemens FDBZ492 duct smoke detector housings equipped with Siemens FDO421 addressable photoelectric heads on all air handling units.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are Siemens XTRI-D addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.  &amp;lt;br&amp;gt;There are Siemens XTRI-R addressable relay modules serving various purposes.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Siemens EL-300C end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:British Columbia]]&lt;br /&gt;
[[Category:Residential]]&lt;br /&gt;
[[Category:Siemens]]&lt;/div&gt;</summary>