<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Secure_Building_SB00001</id>
	<title>Secure Building SB00001 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Secure_Building_SB00001"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Secure_Building_SB00001&amp;action=history"/>
	<updated>2026-05-18T17:47:27Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Secure_Building_SB00001&amp;diff=13066&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&lt;br /&gt;FACP Location: Various&lt;br /&gt;System Type: Two-Stage Networked Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 70.7VRMS (Audible)&lt;br&gt;24VDC (Visual)&lt;br /&gt;System Coding: 20BPM Tone (Alert)&lt;br&gt;Slow Whoop (Alarm)&lt;br&gt;Strobes Synchronized: Yes, EST&lt;br /&gt;Date of last known Upgrade: 2000s&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1990s |}    &#039;...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Secure_Building_SB00001&amp;diff=13066&amp;oldid=prev"/>
		<updated>2025-08-04T21:05:09Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: 20BPM Tone (Alert)&amp;lt;br&amp;gt;Slow Whoop (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1990s |}    &amp;#039;...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards EST3&amp;lt;br /&amp;gt;FACP Location: Various&amp;lt;br /&amp;gt;System Type: Two-Stage Networked Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 70.7VRMS (Audible)&amp;lt;br&amp;gt;24VDC (Visual)&amp;lt;br /&amp;gt;System Coding: 20BPM Tone (Alert)&amp;lt;br&amp;gt;Slow Whoop (Alarm)&amp;lt;br&amp;gt;Strobes Synchronized: Yes, EST&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1990s&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Secure Building SB00001&amp;#039;&amp;#039;&amp;#039; is a secure facility added to Fire Alarmpedia under the Secure Building Information System.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards EST3 addressable fire alarm system. This is a networked system with 6 nodes; node locations will not be disclosed. The system runs Edwards’ Signature addressable protocol, is equipped with voice evacuation, and is configured for two-stage operation. The alert signal is a 20BPM tone, and the alarm signal is slow whoop.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=====FACP Accessories=====&lt;br /&gt;
There are two EST FireWorks workstations on the system.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
Most notification appliances are Edwards 965-1A-8RW remote speakers (white, 8” round, 70V). &amp;lt;br&amp;gt;Electrical and mechanical rooms have Edwards 965-6A-8RW speaker/strobes (white, 8” round, 70V, 15/75cd). &amp;lt;br&amp;gt;The main electrical room has an Edwards “Integrity” 757-1A-R70 remote speaker (red, 70V).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
Staff and service areas have EST SIGA-270P addressable two-stage single-action pull stations. &amp;lt;br&amp;gt;All other areas have custom Edwards/General Signal keyswitch stations.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are a mix of the following addressable smoke detectors throughout all areas: EST SIGA-IPHS, SIGA-PS, SIGA-PD, SIGA-OSD. &amp;lt;br&amp;gt;All detectors are mounted on EST SIGA-SB bases.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising several system components. &amp;lt;br&amp;gt;There are EST SIGA-CR addressable relay modules, the purpose of which will not be disclosed.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all monitored and signal circuits.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Sequence of Operation==&lt;br /&gt;
A first stage alarm will sound 20BPM tones in the common corridors throughout, and the living areas near the alarm. A second stage alarm will sound a slow whoop tone throughout the facility.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Secure Buildings]]&lt;/div&gt;</summary>
		<author><name>TwentyThree33</name></author>
	</entry>
</feed>