<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Sobeys_%28First_Lake%29</id>
	<title>Sobeys (First Lake) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Sobeys_%28First_Lake%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Sobeys_(First_Lake)&amp;action=history"/>
	<updated>2026-09-04T13:52:46Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Sobeys_(First_Lake)&amp;diff=13875&amp;oldid=prev</id>
		<title>TwentyThree33: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Edwards iO1000&lt;br /&gt;FACP Location: Main Entrance Vestibule&lt;br /&gt;System Type: Single-Stage Addressable&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: Yes, Genesis&lt;br /&gt;Date of last known Upgrade: N/A&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 2013 |}  &#039;&#039;&#039;Sobeys&#039;&#039;&#039; is a chain of grocery stores owned by Em...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Sobeys_(First_Lake)&amp;diff=13875&amp;oldid=prev"/>
		<updated>2026-09-03T23:39:21Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2013 |}  &amp;#039;&amp;#039;&amp;#039;Sobeys&amp;#039;&amp;#039;&amp;#039; is a chain of grocery stores owned by Em...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Edwards iO1000&amp;lt;br /&amp;gt;FACP Location: Main Entrance Vestibule&amp;lt;br /&amp;gt;System Type: Single-Stage Addressable&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: Yes, Genesis&amp;lt;br /&amp;gt;Date of last known Upgrade: N/A&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 2013&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Sobeys&amp;#039;&amp;#039;&amp;#039; is a chain of grocery stores owned by Empire.  This particular store is located at 80 First Lake Drive, in Lower Sackville, Nova Scotia, Canada.  The building was built in 2013, and the fire alarm system is original.&lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by an Edwards iO1000 addressable fire alarm system.  The panel is located in the main entrance vestibule.  The system runs Edwards&amp;#039; Signature addressable protocol, and the system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Edwards &amp;quot;Genesis&amp;quot; G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are EST SIGC-270B addressable single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
None noticed.&lt;br /&gt;
&lt;br /&gt;
====Modules====&lt;br /&gt;
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system&amp;#039;s tamper and flow switches.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.&lt;br /&gt;
&lt;br /&gt;
==Credits==&lt;br /&gt;
Thank you to NSS for submitting this system!&lt;br /&gt;
&lt;br /&gt;
[[Category:Nova Scotia]]&lt;br /&gt;
[[Category:Sobeys]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;br /&gt;
[[Category:Edwards]]&lt;/div&gt;</summary>