<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=SouthLake_Church</id>
	<title>SouthLake Church - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=SouthLake_Church"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=SouthLake_Church&amp;action=history"/>
	<updated>2026-04-07T09:03:32Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=SouthLake_Church&amp;diff=12255&amp;oldid=prev</id>
		<title>Somedudewithanexitsign: A YT Classic</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=SouthLake_Church&amp;diff=12255&amp;oldid=prev"/>
		<updated>2025-02-15T08:27:57Z</updated>

		<summary type="html">&lt;p&gt;A YT Classic&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: FCI 7100 &amp;lt;br /&amp;gt;&lt;br /&gt;
Voice Evac Panel: Wheelock DCSP-8RP &amp;lt;br /&amp;gt;&lt;br /&gt;
FACP Location: FACP Room &amp;lt;br /&amp;gt;&lt;br /&gt;
System Type: Addressable &amp;lt;br /&amp;gt; &lt;br /&gt;
System Line Voltage: 120VAC&amp;lt;br /&amp;gt;&lt;br /&gt;
NAC Voltage: 24VDC &amp;lt;br /&amp;gt;&lt;br /&gt;
System Tone: Temporal 3 &amp;lt;br /&amp;gt;&lt;br /&gt;
System Message: Default Wheelock Message &amp;lt;br /&amp;gt;&lt;br /&gt;
Strobes Synchronized: Yes (Wheelock Sync) &amp;lt;br&amp;gt;&lt;br /&gt;
Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;&lt;br /&gt;
Year Opened: 2002 (Original Builiding), 2005 (Addition)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;SouthLake Church&amp;#039;&amp;#039;&amp;#039; is a church that is located at 1555 SW Borland Rd, West Linn, OR. This building was built in 2002 with a addition in 2005. &lt;br /&gt;
&lt;br /&gt;
==System Specifications==&lt;br /&gt;
===FACP===&lt;br /&gt;
The building is protected by a FCI 7100 Addressable fire alarm system with a Wheelock &amp;#039;Safepath&amp;#039; DCSP-8RP Voice Evacuation Panel.  The panel is located in a FACP room.  The system runs FCI&amp;#039;s Clip Protocol addressable protocol, the system tone is Wheelock Temporal 3 Horn, and the system message is the default Wheelock Voice Evac Message&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
The Annunciator is a FCI LCD-7100 LCD Annunciator located in the main lobby by a side exit.&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Wheelock E70-24MCW-FW (White, Wall-Mount, Set on 75cd, 110cd) Speaker Strobes. Smaller areas or areas with extra visual signal covrage have Wheelock RSS-24MCW-FW Strobes (White, Wall-Mount, set on 15cd)&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are in the original 2002 section are FCI MS-6 Conventional Single Action Pull Stations with the 2005 Addition having FCI MS-7A Dual-Action Addressable Pull Stations&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
&lt;br /&gt;
The 2002 Section Features FCI ASD-PL Addressable Photoelectric Smoke Detectors on with a Gamewell FCI ASD-PL2F Addressable Photoelectric Smoke Detector as a deficiency replacement. The 2005 Additon has FCI ASD-PL2 Addressable Photoelectric Smoke Detectors. All Detectors are on System Sensor B710LP Bases&lt;/div&gt;</summary>