<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=St._Mother_Teresa_Church</id>
	<title>St. Mother Teresa Church - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=St._Mother_Teresa_Church"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=St._Mother_Teresa_Church&amp;action=history"/>
	<updated>2026-04-07T10:41:45Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=St._Mother_Teresa_Church&amp;diff=12666&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: None &lt;br /&gt;System Type: 120V Hardwired &lt;br /&gt; System Line Voltage: 120VAC &lt;br /&gt; System Coding: Continuous &lt;br /&gt;Date of last known Upgrade: N/A &lt;br /&gt;Most Recent Known Modification: 2010s (bells &amp; some pull stations) &lt;br /&gt; Year Opened: 1976 |}  &#039;&#039;&#039;St. Mother Teresa Church&#039;&#039;&#039; is a Malabar Catholic church located at 3311 49 St SW, Calgary, Alberta, Canada. It was built in 1976, and...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=St._Mother_Teresa_Church&amp;diff=12666&amp;oldid=prev"/>
		<updated>2025-05-05T04:35:17Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: None &amp;lt;br /&amp;gt;System Type: 120V Hardwired &amp;lt;br /&amp;gt; System Line Voltage: 120VAC &amp;lt;br /&amp;gt; System Coding: Continuous &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s (bells &amp;amp; some pull stations) &amp;lt;br /&amp;gt; Year Opened: 1976 |}  &amp;#039;&amp;#039;&amp;#039;St. Mother Teresa Church&amp;#039;&amp;#039;&amp;#039; is a Malabar Catholic church located at 3311 49 St SW, Calgary, Alberta, Canada. It was built in 1976, and...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: None &amp;lt;br /&amp;gt;System Type: 120V Hardwired &amp;lt;br /&amp;gt; System Line Voltage: 120VAC &amp;lt;br /&amp;gt; System Coding: Continuous &amp;lt;br /&amp;gt;Date of last known Upgrade: N/A &amp;lt;br /&amp;gt;Most Recent Known Modification: 2010s (bells &amp;amp; some pull stations) &amp;lt;br /&amp;gt; Year Opened: 1976&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;St. Mother Teresa Church&amp;#039;&amp;#039;&amp;#039; is a Malabar Catholic church located at 3311 49 St SW, Calgary, Alberta, Canada. It was built in 1976, and the fire alarm system is partially original, with parts replaced as deficiencies occur.&lt;br /&gt;
&lt;br /&gt;
== System Specifications (1976-present) ==&lt;br /&gt;
&lt;br /&gt;
==== FACP ====&lt;br /&gt;
&lt;br /&gt;
The building is protected by a 120VAC hardwired fire alarm system, with bells and initiating devices wired in series. The system coding is continuous.&lt;br /&gt;
&lt;br /&gt;
==== Notification Appliances ====&lt;br /&gt;
&lt;br /&gt;
Most notification appliances are System Sensor SSV120-6A vibrating bells (6&amp;quot; gong). &amp;lt;br&amp;gt; There is one Edwards &amp;quot;Durabel&amp;quot; 6000D vibrating bell (6&amp;quot; gong) in the lobby; the only original bell remaining.&lt;br /&gt;
&lt;br /&gt;
=== Initiating Devices ===&lt;br /&gt;
&lt;br /&gt;
==== Pull Stations ====&lt;br /&gt;
&lt;br /&gt;
Most pull stations are Edwards 270-SPO conventional single-action pull stations. &amp;lt;br&amp;gt; The following pull stations were installed as deficiency replacements: &lt;br /&gt;
* Numerous Edwards 270-SPOE conventional single-action pull stations in the basement dining hall. &lt;br /&gt;
* Secutron MRM-MPG1A conventional single-action pull station in school basement&lt;br /&gt;
* Mircom MS-401 conventional single-action pull station in the gym&lt;br /&gt;
&lt;br /&gt;
==== Automatic Detection Devices ====&lt;br /&gt;
&lt;br /&gt;
There is a mix of the following heat detectors in the hallways, classrooms, storage and janitor rooms, from most common to least. &amp;lt;br&amp;gt;&lt;br /&gt;
* System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors&lt;br /&gt;
* FDD CR-135 conventional 135°F fixed-temperature/rate-of-rise heat detectors&lt;br /&gt;
* Edwards 245A conventional 135°F fixed-temperature heat detectors&lt;br /&gt;
* Edwards 283A conventional 135°F fixed-temperature heat detectors&lt;br /&gt;
&lt;br /&gt;