<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Staples_%28Airdrie%29</id>
	<title>Staples (Airdrie) - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://firealarmpedia.org/index.php?action=history&amp;feed=atom&amp;title=Staples_%28Airdrie%29"/>
	<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Staples_(Airdrie)&amp;action=history"/>
	<updated>2026-04-07T11:23:54Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.41.0</generator>
	<entry>
		<id>https://firealarmpedia.org/index.php?title=Staples_(Airdrie)&amp;diff=12956&amp;oldid=prev</id>
		<title>Alberta Fire Alarms: Created page with &quot;{| style=&quot;float:right;border:2px solid black&quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000&lt;br /&gt;FACP Location: Unknown&lt;br /&gt;System Type: Single-Stage Conventional&lt;br /&gt;System Line Voltage: 120VAC&lt;br /&gt;NAC Voltage: 24VFWR&lt;br /&gt;System Coding: Temporal&lt;br&gt;Strobes Synchronized: No&lt;br /&gt;Date of last known Upgrade: 2000s&lt;br /&gt;Most Recent Known Modification: N/A&lt;br /&gt;Year Opened: 1982 |}  &#039;&#039;&#039;Staples&#039;&#039;&#039; is a chain of office supply stores.  This particular store is...&quot;</title>
		<link rel="alternate" type="text/html" href="https://firealarmpedia.org/index.php?title=Staples_(Airdrie)&amp;diff=12956&amp;oldid=prev"/>
		<updated>2025-06-28T06:50:32Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{| style=&amp;quot;float:right;border:2px solid black&amp;quot; |- ! System Specifications |- |  |- | FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Unknown&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982 |}  &amp;#039;&amp;#039;&amp;#039;Staples&amp;#039;&amp;#039;&amp;#039; is a chain of office supply stores.  This particular store is...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{| style=&amp;quot;float:right;border:2px solid black&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! System Specifications&lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
| FACP: Mircom FA-1000&amp;lt;br /&amp;gt;FACP Location: Unknown&amp;lt;br /&amp;gt;System Type: Single-Stage Conventional&amp;lt;br /&amp;gt;System Line Voltage: 120VAC&amp;lt;br /&amp;gt;NAC Voltage: 24VFWR&amp;lt;br /&amp;gt;System Coding: Temporal&amp;lt;br&amp;gt;Strobes Synchronized: No&amp;lt;br /&amp;gt;Date of last known Upgrade: 2000s&amp;lt;br /&amp;gt;Most Recent Known Modification: N/A&amp;lt;br /&amp;gt;Year Opened: 1982&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Staples&amp;#039;&amp;#039;&amp;#039; is a chain of office supply stores.  This particular store is located in Tower Lane Mall, at 505 Main Street South, in Airdrie, Alberta, Canada.  The building was built in 1982, and the fire alarm system was upgraded in the 2000s.&lt;br /&gt;
&lt;br /&gt;
==System Specifications (2000s-present)==&lt;br /&gt;
====FACP====&lt;br /&gt;
The building is protected by a Mircom FA-1000 conventional fire alarm system.  The panel location is unknown.  The system coding is temporal.&lt;br /&gt;
&lt;br /&gt;
=====Annunciators=====&lt;br /&gt;
There is a Mircom RAM-216 annunciator in the main entrance vestibule.&lt;br /&gt;
&lt;br /&gt;
====Notification Appliances====&lt;br /&gt;
All notification appliances are Mircom &amp;quot;Select-A-Horn/Strobe&amp;quot; FHS-240R horn/strobes (red, wall-mount, set to 15cd).&lt;br /&gt;
&lt;br /&gt;
===Initiating Devices===&lt;br /&gt;
====Pull Stations====&lt;br /&gt;
All pull stations are Mircom MS-401 conventional single-action pull stations.&lt;br /&gt;
&lt;br /&gt;
====Automatic Detection Devices====&lt;br /&gt;
There are System Sensor &amp;quot;Innovair&amp;quot; DH100LPA conventional photoelectric smoke detectors on all rooftop units.&lt;br /&gt;
&lt;br /&gt;
====EOLs====&lt;br /&gt;
There are Mircom MP-300 end of line resistor plates on all circuits.&lt;br /&gt;
&lt;br /&gt;
[[Category:Airdrie]]&lt;br /&gt;
[[Category:Retail Stores]]&lt;/div&gt;</summary>
		<author><name>Alberta Fire Alarms</name></author>
	</entry>
</feed>